CVE-2022-1778
Vulnerability from cvelistv5
Vendor | Product | Version | |
---|---|---|---|
▼ | Hitachi Energy | MicroSCADA X SYS600 |
Version: 10 Version: 10.1 Version: 10.1.1 Version: 10.2 Version: 10.2.1 Version: 10.3 Version: 10.3.1 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:17:00.365Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "MicroSCADA X SYS600", "vendor": "Hitachi Energy", "versions": [ { "status": "affected", "version": "10" }, { "status": "affected", "version": "10.1" }, { "status": "affected", "version": "10.1.1" }, { "status": "affected", "version": "10.2" }, { "status": "affected", "version": "10.2.1" }, { "status": "affected", "version": "10.3" }, { "status": "affected", "version": "10.3.1" } ] } ], "datePublic": "2022-09-05T22:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eImproper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*\u003c/p\u003e" } ], "value": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-25T11:01:22.019Z", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000106\u0026languageCode=en\u0026Preview=true" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eRemediated in SYS600 10.4 \u003c/p\u003e\u003cp\u003eUpdate to at least SYS600 version 10.4.\u003c/p\u003e" } ], "value": "Remediated in SYS600 10.4 \n\nUpdate to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "title": "A vulnerability exists during the start of the affected SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently SYS600 will fail to start. The configuration file can only be accessed by ...", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eApply general mitigation factors as specify in the advisory.\u003c/p\u003e" } ], "value": "Apply general mitigation factors as specify in the advisory." } ], "x_ConverterErrors": { "TITLE": { "error": "TITLE too long. Truncating in v5 record.", "message": "Truncated!" } }, "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "DATE_PUBLIC": "2022-09-06T14:30:00.000Z", "ID": "CVE-2022-1778", "STATE": "PUBLIC", "TITLE": "A vulnerability exists during the start of the affected SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently SYS600 will fail to start. The configuration file can only be accessed by an administrator access." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MicroSCADA X SYS600", "version": { "version_data": [ { "version_affected": "=", "version_value": "10" }, { "version_affected": "=", "version_value": "10.1" }, { "version_affected": "=", "version_value": "10.1.1" }, { "version_affected": "=", "version_value": "10.2" }, { "version_affected": "=", "version_value": "10.2.1" }, { "version_affected": "=", "version_value": "10.3" }, { "version_affected": "=", "version_value": "10.3.1" } ] } } ] }, "vendor_name": "Hitachi Energy" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "solution": [ { "lang": "en", "value": "Remediated in SYS600 10.4 Update to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "value": "Apply general mitigation factors as specify in the advisory." } ] } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2022-1778", "datePublished": "2022-09-14T17:05:36.801368Z", "dateReserved": "2022-05-18T00:00:00", "dateUpdated": "2024-09-25T11:01:22.019Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-1778\",\"sourceIdentifier\":\"cybersecurity@hitachienergy.com\",\"published\":\"2022-09-14T18:15:09.953\",\"lastModified\":\"2024-11-21T06:41:26.900\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de comprobaci\u00f3n de entrada inapropiada en Hitachi Energy MicroSCADA X SYS600 mientras es le\u00eddo un archivo de configuraci\u00f3n espec\u00edfico causa un desbordamiento del b\u00fafer que causa un fallo en el inicio del SYS600. S\u00f3lo puede accederse al archivo de configuraci\u00f3n mediante un acceso de administrador. Este problema afecta a: Hitachi Energy MicroSCADA X SYS600 versi\u00f3n 10 hasta 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*:*\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"10.0\",\"versionEndIncluding\":\"10.3.1\",\"matchCriteriaId\":\"0566FCE7-F150-4DEC-A35C-A8A3EBEE8D3D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"42B6499F-D82D-4B02-BBEC-60B36FB0C678\"}]}]}],\"references\":[{\"url\":\"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000106\u0026languageCode=en\u0026Preview=true\",\"source\":\"cybersecurity@hitachienergy.com\"},{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
icsa-22-272-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Hitachi Energy", "summary": "notifying CISA that these devices were affected" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could cause SYS600 fail to start or an unauthorized actor to run scripts, and could cause a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is exploitable remotely. This vulnerability has a low attack complexity.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-272-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-272-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-272-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-272-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-272-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" } ], "title": "Hitachi Energy MicroSCADA Pro X SYS600", "tracking": { "current_release_date": "2022-09-29T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-272-01", "initial_release_date": "2022-09-29T00:00:00.000000Z", "revision_history": [ { "date": "2022-09-29T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 10.3.1", "product": { "name": "SYS600: 10.3.1 and earlier", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SYS600" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=9.4 FP2 Hotfix 4", "product": { "name": "SYS600: 9.4 FP2 Hotfix 4 and earlier versions", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SYS600" } ], "category": "vendor", "name": "Hitachi Energy" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-1778", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A vulnerability exists during the start of SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently, SYS600 could fail to start. Administrator access is required for accessing the configuration file.CVE-2022-1778 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1778" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "For SYS600: 9.x upgrade to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "For SYS600: 10.x update to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Do not enable ICCP if it is not used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends following 1MRK511518 MicroSCADA X Cyber Security Deployment Guideline", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For additional information and support users should contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Separate process control systems from the internet and other networks using a firewall system with minimal open ports.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or email.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy advisory 8DBD000106", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2022-2277", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the ICCP stack due to a validation flaw in the process establishing the ICCP communication. The validation flaw could cause a denial-of-service condition when ICCP of SYS600 is requested to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled.CVE-2022-2277 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2277" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "For SYS600: 9.x upgrade to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "For SYS600: 10.x update to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Do not enable ICCP if it is not used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends following 1MRK511518 MicroSCADA X Cyber Security Deployment Guideline", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For additional information and support users should contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Separate process control systems from the internet and other networks using a firewall system with minimal open ports.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or email.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy advisory 8DBD000106", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2022-29490", "cwe": { "id": "CWE-269", "name": "Improper Privilege Management" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the Workplace X WebUI, in which an authenticated user could execute any MicroSCADA internal scripts irrespective of the authenticated user\u0027s role.CVE-2022-29490 has been assigned to this vulnerability. A CVSS v3 base score of 8.5 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29490" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "For SYS600: 9.x upgrade to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "For SYS600: 10.x update to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Do not enable ICCP if it is not used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends following 1MRK511518 MicroSCADA X Cyber Security Deployment Guideline", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For additional information and support users should contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Separate process control systems from the internet and other networks using a firewall system with minimal open ports.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or email.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy advisory 8DBD000106", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106" } ], "scores": [ { "cvss_v3": { "baseScore": 8.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2022-29492", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open; this may cause a denial-of-service condition.CVE-2022-29492 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29492" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "For SYS600: 9.x upgrade to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "For SYS600: 10.x update to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Do not enable ICCP if it is not used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends following 1MRK511518 MicroSCADA X Cyber Security Deployment Guideline", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For additional information and support users should contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Separate process control systems from the internet and other networks using a firewall system with minimal open ports.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or email.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy advisory 8DBD000106", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2022-29922", "cwe": { "id": "CWE-241", "name": "Improper Handling of Unexpected Data Type" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server. The vulnerability may cause a denial-of-service condition on the IEC 61850 OPC Server component of the SYS600.CVE-2022-29922 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29922" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "For SYS600: 9.x upgrade to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "For SYS600: 10.x update to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Do not enable ICCP if it is not used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends following 1MRK511518 MicroSCADA X Cyber Security Deployment Guideline", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For additional information and support users should contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Separate process control systems from the internet and other networks using a firewall system with minimal open ports.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or email.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy advisory 8DBD000106", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }
ICSA-23-059-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Hitachi Energy", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could cause part of GWS fail to start, allow unauthorized actors to run scripts, and/or cause a denial-of-service.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.\u00a0", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-23-059-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-059-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-059-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-059-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/Recommended-Practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" } ], "title": "Hitachi Energy Gateway Station", "tracking": { "current_release_date": "2023-03-06T19:52:26.266848Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-059-02", "initial_release_date": "2023-03-06T19:52:26.266848Z", "revision_history": [ { "date": "2023-03-06T19:52:26.266848Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "3.0.0.0", "product": { "name": "Gateway Station (GWS): 3.0.0.0", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Gateway Station (GWS)" }, { "branches": [ { "category": "product_version", "name": "3.1.0.0", "product": { "name": "Gateway Station (GWS): 3.1.0.0", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Gateway Station (GWS)" }, { "branches": [ { "category": "product_version", "name": "3.2.0.0", "product": { "name": "Gateway Station (GWS): 3.2.0.0", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Gateway Station (GWS)" } ], "category": "vendor", "name": "Hitachi Energy" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-2277", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the ICCP stack due to validation flaw in the process establishing the ICCP communication. The validation flaw will cause a denial-of-service condition when ICCP of SYS600 is requested to forward any data item updates with timestamps too far in the future. By default, ICCP is not configured and not enabled. CVE-2022-2277 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2277" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Hitachi Energy has created an update to address the reported vulnerabilities and recommends users update to at least GWS version 3.3.0.0", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Hitachi Energy recommends the following general mitigation factors and security practices:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Configure firewalls to protect process control networks from attacks originating from outside the network", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Physically protect process control systems from direct access by unauthorized personnel", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Avoid directly connecting control systems to the internet", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Separate process control networks from other networks using a firewall system with a minimal number of ports exposed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Enforce proper password policies and processes", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "For more information, see Hitachi security advisory 8DBD000116.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000116" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-29492", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the handling of malformed IEC 104 TCP packets. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped; however, the TCP connection is left open. This may cause a denial-of-service condition if the affected connection is left open. CVE-2022-29492 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29492" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "Hitachi Energy has created an update to address the reported vulnerabilities and recommends users update to at least GWS version 3.3.0.0", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Hitachi Energy recommends the following general mitigation factors and security practices:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Configure firewalls to protect process control networks from attacks originating from outside the network", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Physically protect process control systems from direct access by unauthorized personnel", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Avoid directly connecting control systems to the internet", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Separate process control networks from other networks using a firewall system with a minimal number of ports exposed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Enforce proper password policies and processes", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "For more information, see Hitachi security advisory 8DBD000116.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000116" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-29922", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the handling of specially crafted IEC 61850 packets with a valid data item but incorrect data type in the IEC 61850 OPC Server. The vulnerability may cause a denial-of-service condition on the IEC 61850 OPC Server component of the GWS product. CVE-2022-29922 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29922" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Hitachi Energy has created an update to address the reported vulnerabilities and recommends users update to at least GWS version 3.3.0.0", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Hitachi Energy recommends the following general mitigation factors and security practices:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Configure firewalls to protect process control networks from attacks originating from outside the network", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Physically protect process control systems from direct access by unauthorized personnel", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Avoid directly connecting control systems to the internet", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Separate process control networks from other networks using a firewall system with a minimal number of ports exposed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Enforce proper password policies and processes", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "For more information, see Hitachi security advisory 8DBD000116.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000116" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-1778", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A vulnerability exists during the start of GWS in which an input validation flaw, causing a buffer overflow while reading a specific configuration file. Subsequently, GWS will fail to start. The configuration file can only be accessed by users with administrator access. CVE-2022-1778 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1778" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Hitachi Energy has created an update to address the reported vulnerabilities and recommends users update to at least GWS version 3.3.0.0", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Hitachi Energy recommends the following general mitigation factors and security practices:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Configure firewalls to protect process control networks from attacks originating from outside the network", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Physically protect process control systems from direct access by unauthorized personnel", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Avoid directly connecting control systems to the internet", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Separate process control networks from other networks using a firewall system with a minimal number of ports exposed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Enforce proper password policies and processes", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "For more information, see Hitachi security advisory 8DBD000116.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000116" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] } ] }
ICSA-22-272-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Hitachi Energy", "summary": "notifying CISA that these devices were affected" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could cause SYS600 fail to start or an unauthorized actor to run scripts, and could cause a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target this vulnerability. This vulnerability is exploitable remotely. This vulnerability has a low attack complexity.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-272-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-272-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-272-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-272-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-272-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" } ], "title": "Hitachi Energy MicroSCADA Pro X SYS600", "tracking": { "current_release_date": "2022-09-29T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-272-01", "initial_release_date": "2022-09-29T00:00:00.000000Z", "revision_history": [ { "date": "2022-09-29T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 10.3.1", "product": { "name": "SYS600: 10.3.1 and earlier", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SYS600" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=9.4 FP2 Hotfix 4", "product": { "name": "SYS600: 9.4 FP2 Hotfix 4 and earlier versions", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SYS600" } ], "category": "vendor", "name": "Hitachi Energy" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-1778", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A vulnerability exists during the start of SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently, SYS600 could fail to start. Administrator access is required for accessing the configuration file.CVE-2022-1778 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1778" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "For SYS600: 9.x upgrade to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "For SYS600: 10.x update to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Do not enable ICCP if it is not used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends following 1MRK511518 MicroSCADA X Cyber Security Deployment Guideline", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For additional information and support users should contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Separate process control systems from the internet and other networks using a firewall system with minimal open ports.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or email.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy advisory 8DBD000106", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2022-2277", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the ICCP stack due to a validation flaw in the process establishing the ICCP communication. The validation flaw could cause a denial-of-service condition when ICCP of SYS600 is requested to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled.CVE-2022-2277 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2277" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "For SYS600: 9.x upgrade to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "For SYS600: 10.x update to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Do not enable ICCP if it is not used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends following 1MRK511518 MicroSCADA X Cyber Security Deployment Guideline", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For additional information and support users should contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Separate process control systems from the internet and other networks using a firewall system with minimal open ports.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or email.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy advisory 8DBD000106", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2022-29490", "cwe": { "id": "CWE-269", "name": "Improper Privilege Management" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the Workplace X WebUI, in which an authenticated user could execute any MicroSCADA internal scripts irrespective of the authenticated user\u0027s role.CVE-2022-29490 has been assigned to this vulnerability. A CVSS v3 base score of 8.5 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29490" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "For SYS600: 9.x upgrade to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "For SYS600: 10.x update to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Do not enable ICCP if it is not used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends following 1MRK511518 MicroSCADA X Cyber Security Deployment Guideline", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For additional information and support users should contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Separate process control systems from the internet and other networks using a firewall system with minimal open ports.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or email.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy advisory 8DBD000106", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106" } ], "scores": [ { "cvss_v3": { "baseScore": 8.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2022-29492", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open; this may cause a denial-of-service condition.CVE-2022-29492 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29492" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "For SYS600: 9.x upgrade to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "For SYS600: 10.x update to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Do not enable ICCP if it is not used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends following 1MRK511518 MicroSCADA X Cyber Security Deployment Guideline", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For additional information and support users should contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Separate process control systems from the internet and other networks using a firewall system with minimal open ports.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or email.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy advisory 8DBD000106", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2022-29922", "cwe": { "id": "CWE-241", "name": "Improper Handling of Unexpected Data Type" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server. The vulnerability may cause a denial-of-service condition on the IEC 61850 OPC Server component of the SYS600.CVE-2022-29922 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29922" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "For SYS600: 9.x upgrade to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "For SYS600: 10.x update to at least SYS600 version 10.4.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Do not enable ICCP if it is not used.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends following 1MRK511518 MicroSCADA X Cyber Security Deployment Guideline", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For additional information and support users should contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Separate process control systems from the internet and other networks using a firewall system with minimal open ports.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or email.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy advisory 8DBD000106", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }
icsa-23-059-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Hitachi Energy", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could cause part of GWS fail to start, allow unauthorized actors to run scripts, and/or cause a denial-of-service.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have low attack complexity.\u00a0", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-23-059-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-059-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-059-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-059-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/Recommended-Practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://cisa.gov/ics" } ], "title": "Hitachi Energy Gateway Station", "tracking": { "current_release_date": "2023-03-06T19:52:26.266848Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-23-059-02", "initial_release_date": "2023-03-06T19:52:26.266848Z", "revision_history": [ { "date": "2023-03-06T19:52:26.266848Z", "legacy_version": "1", "number": "1", "summary": "CSAF Creation Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "3.0.0.0", "product": { "name": "Gateway Station (GWS): 3.0.0.0", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Gateway Station (GWS)" }, { "branches": [ { "category": "product_version", "name": "3.1.0.0", "product": { "name": "Gateway Station (GWS): 3.1.0.0", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Gateway Station (GWS)" }, { "branches": [ { "category": "product_version", "name": "3.2.0.0", "product": { "name": "Gateway Station (GWS): 3.2.0.0", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Gateway Station (GWS)" } ], "category": "vendor", "name": "Hitachi Energy" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-2277", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the ICCP stack due to validation flaw in the process establishing the ICCP communication. The validation flaw will cause a denial-of-service condition when ICCP of SYS600 is requested to forward any data item updates with timestamps too far in the future. By default, ICCP is not configured and not enabled. CVE-2022-2277 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-2277" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Hitachi Energy has created an update to address the reported vulnerabilities and recommends users update to at least GWS version 3.3.0.0", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Hitachi Energy recommends the following general mitigation factors and security practices:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Configure firewalls to protect process control networks from attacks originating from outside the network", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Physically protect process control systems from direct access by unauthorized personnel", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Avoid directly connecting control systems to the internet", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Separate process control networks from other networks using a firewall system with a minimal number of ports exposed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Enforce proper password policies and processes", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "For more information, see Hitachi security advisory 8DBD000116.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000116" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-29492", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the handling of malformed IEC 104 TCP packets. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped; however, the TCP connection is left open. This may cause a denial-of-service condition if the affected connection is left open. CVE-2022-29492 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29492" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "Hitachi Energy has created an update to address the reported vulnerabilities and recommends users update to at least GWS version 3.3.0.0", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Hitachi Energy recommends the following general mitigation factors and security practices:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Configure firewalls to protect process control networks from attacks originating from outside the network", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Physically protect process control systems from direct access by unauthorized personnel", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Avoid directly connecting control systems to the internet", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Separate process control networks from other networks using a firewall system with a minimal number of ports exposed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Enforce proper password policies and processes", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "For more information, see Hitachi security advisory 8DBD000116.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000116" } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-29922", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the handling of specially crafted IEC 61850 packets with a valid data item but incorrect data type in the IEC 61850 OPC Server. The vulnerability may cause a denial-of-service condition on the IEC 61850 OPC Server component of the GWS product. CVE-2022-29922 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-29922" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Hitachi Energy has created an update to address the reported vulnerabilities and recommends users update to at least GWS version 3.3.0.0", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Hitachi Energy recommends the following general mitigation factors and security practices:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Configure firewalls to protect process control networks from attacks originating from outside the network", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Physically protect process control systems from direct access by unauthorized personnel", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Avoid directly connecting control systems to the internet", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Separate process control networks from other networks using a firewall system with a minimal number of ports exposed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Enforce proper password policies and processes", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "For more information, see Hitachi security advisory 8DBD000116.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000116" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2022-1778", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A vulnerability exists during the start of GWS in which an input validation flaw, causing a buffer overflow while reading a specific configuration file. Subsequently, GWS will fail to start. The configuration file can only be accessed by users with administrator access. CVE-2022-1778 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-1778" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Hitachi Energy has created an update to address the reported vulnerabilities and recommends users update to at least GWS version 3.3.0.0", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Hitachi Energy recommends the following general mitigation factors and security practices:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Configure firewalls to protect process control networks from attacks originating from outside the network", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Physically protect process control systems from direct access by unauthorized personnel", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Avoid directly connecting control systems to the internet", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Separate process control networks from other networks using a firewall system with a minimal number of ports exposed", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Enforce proper password policies and processes", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "For more information, see Hitachi security advisory 8DBD000116.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000116" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] } ] }
ghsa-84rx-9qxm-ffcf
Vulnerability from github
Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3::::::: cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:::::::*
{ "affected": [], "aliases": [ "CVE-2022-1778" ], "database_specific": { "cwe_ids": [ "CWE-119", "CWE-120", "CWE-20" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-09-14T18:15:00Z", "severity": "MODERATE" }, "details": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*", "id": "GHSA-84rx-9qxm-ffcf", "modified": "2024-09-23T12:31:09Z", "published": "2022-09-15T00:00:16Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-1778" }, { "type": "WEB", "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000106\u0026languageCode=en\u0026Preview=true" }, { "type": "WEB", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "type": "CVSS_V3" } ] }
fkie_cve-2022-1778
Vulnerability from fkie_nvd
4.4 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
Vendor | Product | Version | |
---|---|---|---|
hitachienergy | microscada_x_sys600 | * | |
hitachienergy | sys600 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*", "matchCriteriaId": "0566FCE7-F150-4DEC-A35C-A8A3EBEE8D3D", "versionEndIncluding": "10.3.1", "versionStartIncluding": "10.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*", "matchCriteriaId": "42B6499F-D82D-4B02-BBEC-60B36FB0C678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" }, { "lang": "es", "value": "Una vulnerabilidad de comprobaci\u00f3n de entrada inapropiada en Hitachi Energy MicroSCADA X SYS600 mientras es le\u00eddo un archivo de configuraci\u00f3n espec\u00edfico causa un desbordamiento del b\u00fafer que causa un fallo en el inicio del SYS600. S\u00f3lo puede accederse al archivo de configuraci\u00f3n mediante un acceso de administrador. Este problema afecta a: Hitachi Energy MicroSCADA X SYS600 versi\u00f3n 10 hasta 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:cpe:2. 3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*:*" } ], "id": "CVE-2022-1778", "lastModified": "2024-11-21T06:41:26.900", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-09-14T18:15:09.953", "references": [ { "source": "cybersecurity@hitachienergy.com", "url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000106\u0026languageCode=en\u0026Preview=true" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@hitachienergy.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "cybersecurity@hitachienergy.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
gsd-2022-1778
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-1778", "description": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*", "id": "GSD-2022-1778" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-1778" ], "details": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*", "id": "GSD-2022-1778", "modified": "2023-12-13T01:19:28.001399Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "DATE_PUBLIC": "2022-09-06T14:30:00.000Z", "ID": "CVE-2022-1778", "STATE": "PUBLIC", "TITLE": "A vulnerability exists during the start of the affected SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently SYS600 will fail to start. The configuration file can only be accessed by an administrator access." }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MicroSCADA X SYS600", "version": { "version_data": [ { "version_affected": "=", "version_value": "10" }, { "version_affected": "=", "version_value": "10.1" }, { "version_affected": "=", "version_value": "10.1.1" }, { "version_affected": "=", "version_value": "10.2" }, { "version_affected": "=", "version_value": "10.2.1" }, { "version_affected": "=", "version_value": "10.3" }, { "version_affected": "=", "version_value": "10.3.1" } ] } } ] }, "vendor_name": "Hitachi Energy" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "solution": [ { "lang": "eng", "value": "Remediated in SYS600 10.4 \nUpdate to at least SYS600 version 10.4." } ], "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "eng", "value": "Apply general mitigation factors as specify in the advisory. " } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "10.3.1", "versionStartIncluding": "10.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:hitachienergy:sys600:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "ID": "CVE-2022-1778" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-119" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 3.6 } }, "lastModifiedDate": "2023-06-27T15:47Z", "publishedDate": "2022-09-14T18:15Z" } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.