An out-of-bounds read issue exists in the DWG file-recovering procedure in the Drawings SDK (All versions prior to 2022.5) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations.
CWE
  • CWE-125 - OUT-OF-BOUNDS READ CWE-125
Impacted products
Vendor Product Version CPE status
n/a Drawings SDK Affected: All versions prior to 2022.4
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:33:56.100Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-986/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Drawings SDK",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to 2022.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An out-of-bounds read issue exists in the DWG file-recovering procedure in the Drawings SDK (All versions prior to 2022.5) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "OUT-OF-BOUNDS READ CWE-125",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-13T00:00:00.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf"
        },
        {
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-986/"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-32940",
    "datePublished": "2021-06-17T00:00:00.000Z",
    "dateReserved": "2021-05-13T00:00:00.000Z",
    "dateUpdated": "2024-08-03T23:33:56.100Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-32940",
      "date": "2026-09-19",
      "epss": "0.0205",
      "percentile": "0.8037"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "39F1770F-CDAF-48FC-9153-6B23906D8D9C",
                  "versionEndExcluding": "2022.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F0CFB85-CD4F-424C-8B9F-9289D08FA665",
                  "versionEndExcluding": "10.4.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C811E8B2-CA0C-4A71-A803-A30C4DAF1476",
                  "versionEndExcluding": "13.2.0.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "87BB2370-46C4-4BEC-8189-1F7FE4C1E12D",
                  "versionEndExcluding": "13.2.0.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An out-of-bounds read issue exists in the DWG file-recovering procedure in the Drawings SDK (All versions prior to 2022.5) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations."
        },
        {
          "lang": "es",
          "value": "Se presenta un problema de lectura fuera de l\u00edmites en el procedimiento de recuperaci\u00f3n de archivos DWG en Drawings SDK (todas las versiones anteriores a 2022.4) resultando en una falta de comprobaci\u00f3n apropiada de los datos suministrados por el usuario. Esto puede resultar en una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado y permitir a atacantes causar una condici\u00f3n de denegaci\u00f3n de servicio o leer informaci\u00f3n confidencial de las ubicaciones de memoria"
        }
      ],
      "id": "CVE-2021-32940",
      "lastModified": "2024-11-21T06:07:58.200",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 4.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.1,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2021-06-17T13:15:07.923",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02"
        },
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-986/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-986/"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-125"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "39F1770F-CDAF-48FC-9153-6B23906D8D9C",
                    "versionEndExcluding": "2022.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0F0CFB85-CD4F-424C-8B9F-9289D08FA665",
                    "versionEndExcluding": "10.4.1",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C811E8B2-CA0C-4A71-A803-A30C4DAF1476",
                    "versionEndExcluding": "13.2.0.1",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "87BB2370-46C4-4BEC-8189-1F7FE4C1E12D",
                    "versionEndExcluding": "13.2.0.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An out-of-bounds read issue exists in the DWG file-recovering procedure in the Drawings SDK (All versions prior to 2022.5) resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or read sensitive information from memory locations."
          },
          {
            "lang": "es",
            "value": "Se presenta un problema de lectura fuera de l\u00edmites en el procedimiento de recuperaci\u00f3n de archivos DWG en Drawings SDK (todas las versiones anteriores a 2022.4) resultando en una falta de comprobaci\u00f3n apropiada de los datos suministrados por el usuario. Esto puede resultar en una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado y permitir a atacantes causar una condici\u00f3n de denegaci\u00f3n de servicio o leer informaci\u00f3n confidencial de las ubicaciones de memoria"
          }
        ],
        "id": "CVE-2021-32940",
        "lastModified": "2024-11-21T06:07:58.200",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 8.6,
              "impactScore": 4.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.2,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2021-06-17T13:15:07.923",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Patch",
              "Third Party Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Patch",
              "Third Party Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-986/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Patch",
              "Third Party Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Patch",
              "Third Party Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-02"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-986/"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-125"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Primary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-125"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T14:01:01+00:00",
      "cve": "CVE-2021-32940",
      "id": "CVE-2021-32940",
      "initial_release_date": "2021-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2021-32940",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-32940.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…