GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2021-22716 (GCVE-0-2021-22716)

Vulnerability from cvelistv5 – Published: 2021-04-13 18:31 – Updated: 2024-09-16 22:02
VLAI
Summary
A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)
CWE
  • CWE-732 - Incorrect Permission Assignment for Critical Resource
Impacted products
Vendor Product Version CPE status
Schneider Electric C-Bus Toolkit Affected: V , < 1.15.9 (custom)
guessed Create a notification for this product.
Date Public
2022-11-08 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:51:06.795Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "C-Bus Toolkit",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "1.15.9",
              "status": "affected",
              "version": "V",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-11-08T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-18T00:00:00.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf"
        },
        {
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2021-22716",
    "datePublished": "2021-04-13T18:31:18.018Z",
    "dateReserved": "2021-01-06T00:00:00.000Z",
    "dateUpdated": "2024-09-16T22:02:57.408Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-22716",
      "date": "2026-09-17",
      "epss": "0.00765",
      "percentile": "0.53765"
    },
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.15.7\", \"matchCriteriaId\": \"F0CC2C60-78DD-4959-B70F-CF0A3073FC56\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)\"}, {\"lang\": \"es\", \"value\": \"Una  CWE-732: Asignaci\\u00f3n incorrecta de permisos para recursos cr\\u00edticos que podr\\u00eda permitir la ejecuci\\u00f3n remota de c\\u00f3digo cuando un usuario sin privilegios modifica un archivo. Producto afectado: C-Bus Toolkit (V1.15.9 y anteriores)\"}]",
      "id": "CVE-2021-22716",
      "lastModified": "2024-11-21T05:50:31.200",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 4.6, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.9, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-04-13T19:15:14.210",
      "references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf\", \"source\": \"cybersecurity@se.com\"}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01\", \"source\": \"cybersecurity@se.com\"}, {\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-732\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-732\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-22716\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2021-04-13T19:15:14.210\",\"lastModified\":\"2024-11-21T05:50:31.200\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)\"},{\"lang\":\"es\",\"value\":\"Una  CWE-732: Asignaci\u00f3n incorrecta de permisos para recursos cr\u00edticos que podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo cuando un usuario sin privilegios modifica un archivo. Producto afectado: C-Bus Toolkit (V1.15.9 y anteriores)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:c-bus_toolkit:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.15.7\",\"matchCriteriaId\":\"F0CC2C60-78DD-4959-B70F-CF0A3073FC56\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf\",\"source\":\"cybersecurity@se.com\"},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01\",\"source\":\"cybersecurity@se.com\"},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-103-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-103-01_C-Bus_Toolkit_C-Gate_Server_Security_Notification.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-105-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
    "redhat_vex": {
      "current_release_date": "2026-03-27T14:49:19+00:00",
      "cve": "CVE-2021-22716",
      "id": "CVE-2021-22716",
      "initial_release_date": "2021-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2021-22716",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-22716.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…