CVE-2020-7461 (GCVE-0-2020-7461)
Vulnerability from cvelistv5
- Heap-based Buffer Overflow
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:25:49.113Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "FreeBSD", "vendor": "n/a", "versions": [ { "status": "affected", "version": "FreeBSD 12.1-RELEASE before p9, 11.4-RELEASE before p3, 11.3-RELEASE before p13" } ] } ], "descriptions": [ { "lang": "en", "value": "In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit." } ], "problemTypes": [ { "descriptions": [ { "description": "Heap-based Buffer Overflow", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-14T12:06:27", "orgId": "63664ac6-956c-4cba-a5d0-f46076e16109", "shortName": "freebsd" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secteam@freebsd.org", "ID": "CVE-2020-7461", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "FreeBSD", "version": { "version_data": [ { "version_value": "FreeBSD 12.1-RELEASE before p9, 11.4-RELEASE before p3, 11.3-RELEASE before p13" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc", "refsource": "MISC", "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "63664ac6-956c-4cba-a5d0-f46076e16109", "assignerShortName": "freebsd", "cveId": "CVE-2020-7461", "datePublished": "2021-03-26T20:55:08", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:25:49.113Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-7461\",\"sourceIdentifier\":\"secteam@freebsd.org\",\"published\":\"2021-03-26T21:15:13.053\",\"lastModified\":\"2024-11-21T05:37:11.450\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit.\"},{\"lang\":\"es\",\"value\":\"En FreeBSD versiones 12.1-STABLE anteriores a r365010, 11.4-STABLE anteriores a r365011, 12.1-RELEASE anteriores a p9, 11.4-RELEASE anteriores a p3 y 11.3-RELEASE anteriores a p13, dhclient(8) no puede manejar determinadas entradas malformadas relacionadas con el manejo de la opci\u00f3n 119 de DHCP resultando en un desbordamiento de la pila.\u0026#xa0;En principio, el desbordamiento de la pila podr\u00eda explotarse para lograr una ejecuci\u00f3n de c\u00f3digo remota.\u0026#xa0;El proceso afectado se ejecuta con privilegios reducidos en un sandbox Capsicum, limitando el impacto inmediato de una explotaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"F35957CE-AF9F-40CA-BDD1-FA6A0E73783F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p1:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA929713-B797-494A-853D-C121D9D69519\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p10:*:*:*:*:*:*\",\"matchCriteriaId\":\"B87AF171-95AC-4DDA-8D94-694F85638B46\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p11:*:*:*:*:*:*\",\"matchCriteriaId\":\"1CC8B031-41BB-4846-B092-7E4BC6F35D6B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p12:*:*:*:*:*:*\",\"matchCriteriaId\":\"83E34012-BC9D-4F0C-AAE1-FE5767B4EED6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p2:*:*:*:*:*:*\",\"matchCriteriaId\":\"3C3D8EDC-91D3-45B2-AC1D-EF4346D4A714\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p3:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA5006FF-06A5-4D95-BF5B-29F26248D11F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p4:*:*:*:*:*:*\",\"matchCriteriaId\":\"A705031B-FD63-4076-B92E-E826E11D7111\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p5:*:*:*:*:*:*\",\"matchCriteriaId\":\"11C1EFB1-68E5-45F4-A7E1-744574F290D1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p6:*:*:*:*:*:*\",\"matchCriteriaId\":\"25F649A7-9265-4552-8934-BCE083363982\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p7:*:*:*:*:*:*\",\"matchCriteriaId\":\"F202C856-5B95-4796-AC4A-1F210E7BAB8F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p8:*:*:*:*:*:*\",\"matchCriteriaId\":\"9419C866-C478-4CDE-A9A1-E592D8FF0933\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.3:p9:*:*:*:*:*:*\",\"matchCriteriaId\":\"2B6DFC23-A7A1-431A-9AD9-A820579F95F0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.4:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4A865EA1-01D7-4E5A-9D13-80780F8A9D7A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.4:p1:*:*:*:*:*:*\",\"matchCriteriaId\":\"9FCA6A72-2A72-45FD-A43D-B5BF7C329121\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:11.4:p2:*:*:*:*:*:*\",\"matchCriteriaId\":\"90F9B3CB-3B60-4AA8-9EAF-4F0BE7D27691\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:12.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD730B6A-F123-4685-ACB3-4F20AAAB77F3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:12.1:p1:*:*:*:*:*:*\",\"matchCriteriaId\":\"508150E3-2C0C-4EEB-BFC9-BB5CEB404C06\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:12.1:p2:*:*:*:*:*:*\",\"matchCriteriaId\":\"B5D692EF-A5D7-430E-91BA-4CD137343B66\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:12.1:p3:*:*:*:*:*:*\",\"matchCriteriaId\":\"D50C60A7-4C9F-4636-92E9-9F5B8B01BE5B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:12.1:p4:*:*:*:*:*:*\",\"matchCriteriaId\":\"6C49F6C7-A740-42F4-93BB-512CBF334516\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:12.1:p5:*:*:*:*:*:*\",\"matchCriteriaId\":\"402740C4-5B55-423F-BAD2-F742E1E21ADC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:12.1:p6:*:*:*:*:*:*\",\"matchCriteriaId\":\"9DCAA10A-C612-45E0-84B7-55897F49D65E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:12.1:p7:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB6258A5-8066-48B8-A417-09A1547DD57A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:freebsd:freebsd:12.1:p8:*:*:*:*:*:*\",\"matchCriteriaId\":\"6601C7C4-EC36-4EAA-90AC-D3156A2BF330\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rf350m_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5B60EA5E-219D-44E8-800B-97AB739B5895\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rf350m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E4B5DF0A-2850-4BFA-B110-36F2BE323A28\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rf650m_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0B1DF7FC-EE60-48EE-8301-B8BDED3FD33E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rf650m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7DAE6641-16B6-4B41-B170-DAB51DF5AEC2\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf\",\"source\":\"secteam@freebsd.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc\",\"source\":\"secteam@freebsd.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
ICSA-21-257-11
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "A heap overflow vulnerability in dhclient of the affected products, which has been published alongside other vulnerabilities as part of NAME:WRECK could allow an attacker to potentially remotely execute code.\n\nSiemens recommends specific countermeasures for products.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-288459: Heap Overflow Vulnerability in RFID terminals - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-288459.json" }, { "category": "self", "summary": "SSA-288459: Heap Overflow Vulnerability in RFID terminals - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-288459.txt" }, { "category": "self", "summary": "SSA-288459: Heap Overflow Vulnerability in RFID terminals - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-257-11 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-257-11.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-257-11 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-257-11" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SIMATIC RFID", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-257-11", "initial_release_date": "2021-09-14T00:00:00.000000Z", "revision_history": [ { "date": "2021-09-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC RF350M", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIMATIC RF350M" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC RF650M", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SIMATIC RF650M" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-7461", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-7461 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-7461.json" } ], "remediations": [ { "category": "none_available", "details": "Currently no remediation is available", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Use trusted DNS servers in internal network, and restrict DNS traffic to this network only through firewalls.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Protect network access to affected devices.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:U/RL:U/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-7461" } ] }
icsa-21-257-11
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "A heap overflow vulnerability in dhclient of the affected products, which has been published alongside other vulnerabilities as part of NAME:WRECK could allow an attacker to potentially remotely execute code.\n\nSiemens recommends specific countermeasures for products.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-288459: Heap Overflow Vulnerability in RFID terminals - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-288459.json" }, { "category": "self", "summary": "SSA-288459: Heap Overflow Vulnerability in RFID terminals - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-288459.txt" }, { "category": "self", "summary": "SSA-288459: Heap Overflow Vulnerability in RFID terminals - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-257-11 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-257-11.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-257-11 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-257-11" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SIMATIC RFID", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-257-11", "initial_release_date": "2021-09-14T00:00:00.000000Z", "revision_history": [ { "date": "2021-09-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC RF350M", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIMATIC RF350M" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC RF650M", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SIMATIC RF650M" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-7461", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-7461 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-7461.json" } ], "remediations": [ { "category": "none_available", "details": "Currently no remediation is available", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Use trusted DNS servers in internal network, and restrict DNS traffic to this network only through firewalls.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "workaround", "details": "Protect network access to affected devices.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:U/RL:U/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-7461" } ] }
ghsa-x566-m9mc-f47w
Vulnerability from github
In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit.
{ "affected": [], "aliases": [ "CVE-2020-7461" ], "database_specific": { "cwe_ids": [ "CWE-787" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-03-26T21:15:00Z", "severity": "HIGH" }, "details": "In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit.", "id": "GHSA-x566-m9mc-f47w", "modified": "2022-05-24T17:45:30Z", "published": "2022-05-24T17:45:30Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-7461" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" }, { "type": "WEB", "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc" } ], "schema_version": "1.4.0", "severity": [] }
CERTFR-2021-AVI-706
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | Industrial Edge Management versions antérieures à V1.3 | ||
Siemens | N/A | SIMATIC RF350M toutes versions | ||
Siemens | N/A | SIPROTEC 5 relays with CPU variants CP050 versions antérieures à V8.80 | ||
Siemens | N/A | SCALANCE X204-2TS versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X306-1LD FE toutes versions | ||
Siemens | N/A | TALON TC Modular (BACnet) versions antérieures à V3.5.3 | ||
Siemens | N/A | SIMATIC CP 443-1 Advanced (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX RX1501 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE X201-3P IRT PRO toutes versions | ||
Siemens | N/A | APOGEE MBC (PPC) (P2 Ethernet) toutes versions >= V2.6.3 | ||
Siemens | N/A | Teamcenter V12.4 versions antérieures à V12.4.0.8 | ||
Siemens | N/A | SCALANCE X302-7 EEC toutes versions | ||
Siemens | N/A | Desigo CC V4.0 toutes versions | ||
Siemens | N/A | SCALANCE X304-2FE toutes versions | ||
Siemens | N/A | APOGEE PXC Modular (P2 Ethernet) toutes versions >= V2.8 | ||
Siemens | N/A | APOGEE MEC (PPC) (P2 Ethernet) toutes versions >= V2.6.3 | ||
Siemens | N/A | SINEC NMS versions antérieures à V1.0 SP1 | ||
Siemens | N/A | SCALANCE X202-2 IRT toutes versions | ||
Siemens | N/A | SIMATIC CP 1543-1 (incl. SIPLUS variants) versions antérieures à V3.0 | ||
Siemens | N/A | SIPROTEC 5 relays with CPU variants CP300 versions antérieures à V8.80 | ||
Siemens | N/A | SCALANCE X308-2LD toutes versions | ||
Siemens | N/A | SCALANCE X212-2 (incl. SIPLUS NET variant) versions antérieures à V5.2.5 | ||
Siemens | N/A | RUGGEDCOM ROX RX1524 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE XR324-4M PoE toutes versions | ||
Siemens | N/A | Desigo CC toutes versions with OIS Extension Module | ||
Siemens | N/A | Teamcenter Active Workspace V4.3 versions antérieures à V4.3.10 | ||
Siemens | N/A | SCALANCE X310 toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX RX5000 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE X308-2LH+ toutes versions | ||
Siemens | N/A | NX 1980 Series versions antérieures à V1984 | ||
Siemens | N/A | Simcenter STAR-CCM+ Viewer versions antérieures à V2021.2.1 | ||
Siemens | N/A | SCALANCE X204 IRT PRO toutes versions | ||
Siemens | N/A | SCALANCE XR324-12M toutes versions | ||
Siemens | N/A | Teamcenter Active Workspace V5.2 versions antérieures à V5.2.1 | ||
Siemens | N/A | SCALANCE X308-2M toutes versions | ||
Siemens | N/A | Siveillance Control toutes versions with OIS running on Debian 9 or earlier | ||
Siemens | N/A | RUGGEDCOM ROX RX1400 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE X408-2 toutes versions | ||
Siemens | N/A | APOGEE PXC Compact (P2 Ethernet) toutes versions >= V2.8 | ||
Siemens | N/A | SCALANCE X308-2M TS toutes versions | ||
Siemens | N/A | Operation Scheduler toutes versions with OIS running on Debian 9 or earlier | ||
Siemens | N/A | SCALANCE XR324-4M PoE TS toutes versions | ||
Siemens | N/A | Desigo CC V4.1 toutes versions | ||
Siemens | N/A | Desigo CC Compact V4.0 toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX RX1512 versions antérieures à V2.14.1 | ||
Siemens | N/A | Simcenter Femap V2020.2 toutes versions | ||
Siemens | N/A | SCALANCE XF204 IRT toutes versions | ||
Siemens | N/A | Desigo CC V4.2 toutes versions | ||
Siemens | N/A | Teamcenter V13.0 versions antérieures à V13.0.0.7 | ||
Siemens | N/A | SCALANCE X201-3P IRT toutes versions | ||
Siemens | N/A | SCALANCE XF202-2P IRT toutes versions | ||
Siemens | N/A | SCALANCE XF204-2BA IRT toutes versions | ||
Siemens | N/A | SCALANCE XF206-1 versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE XF201-3P IRT toutes versions | ||
Siemens | N/A | SCALANCE X307-3LD toutes versions | ||
Siemens | N/A | Simcenter Femap V2021.1 toutes versions | ||
Siemens | N/A | SCALANCE X307-3 toutes versions | ||
Siemens | N/A | SIPROTEC 5 relays with CPU variants CP200 toutes versions | ||
Siemens | N/A | SIMATIC RF650M toutes versions | ||
Siemens | N/A | Siveillance Control Pro toutes versions | ||
Siemens | N/A | SCALANCE X310FE toutes versions | ||
Siemens | N/A | Cerberus DMS V5.0 versions antérieures à v5.0 QU1 | ||
Siemens | N/A | SINEMA Server versions antérieures à V14 SP3 | ||
Siemens | N/A | TALON TC Compact (BACnet) versions antérieures à V3.5.3 | ||
Siemens | N/A | SCALANCE X202-2P IRT (incl. SIPLUS NET variant) toutes versions | ||
Siemens | N/A | APOGEE PXC Compact (BACnet) versions antérieures à V3.5.3 | ||
Siemens | N/A | SCALANCE X224 versions antérieures à V5.2.5 | ||
Siemens | N/A | SIMATIC CP 343-1 Lean (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | SIMATIC CP 343-1 (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | SCALANCE XR324-12M TS toutes versions | ||
Siemens | N/A | Cerberus DMS V4.2 toutes versions | ||
Siemens | N/A | SCALANCE X320-1-2LD FE toutes versions | ||
Siemens | N/A | SIMATIC RTU 3000 family toutes versions | ||
Siemens | N/A | SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX MX5000 versions antérieures à V2.14.1 | ||
Siemens | N/A | Teamcenter V13.1 versions antérieures à V13.1.0.5 | ||
Siemens | N/A | SIMATIC CP 1545-1 toutes versions | ||
Siemens | N/A | Desigo CC Compact V5.0 versions antérieures à V5.0 QU1 | ||
Siemens | N/A | SCALANCE XF208 versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X308-2LH toutes versions | ||
Siemens | N/A | SCALANCE X204-2 (incl. SIPLUS NET variant) versions antérieures à V5.2.5 | ||
Siemens | N/A | RUGGEDCOM ROX RX1511 versions antérieures à V2.14.1 | ||
Siemens | N/A | RUGGEDCOM ROX RX1500 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE X200-4P IRT toutes versions | ||
Siemens | N/A | Teamcenter V13.2 versions antérieures à 13.2.0.2 | ||
Siemens | N/A | SCALANCE XR324-4M EEC toutes versions | ||
Siemens | N/A | SCALANCE XF204 versions antérieures à V5.2.5 | ||
Siemens | N/A | Desigo CC V5.0 versions antérieures à V5.0 QU1 | ||
Siemens | N/A | SCALANCE X307-2 EEC toutes versions | ||
Siemens | N/A | SCALANCE X320-1 FE toutes versions | ||
Siemens | N/A | SCALANCE X204-2FM versions antérieures à V5.2.5 | ||
Siemens | N/A | GMA-Manager toutes versions with OIS running on Debian 9 or earlier | ||
Siemens | N/A | SIMATIC CP 443-1 (incl. SIPLUS variants) toutes versions | ||
Siemens | N/A | SCALANCE X202-2P IRT PRO toutes versions | ||
Siemens | N/A | Cerberus DMS V4.0 toutes versions | ||
Siemens | N/A | SINEMA Remote Connect Server versions antérieures à V3.0 SP2 | ||
Siemens | N/A | LOGO! CMR2020 versions antérieures à V2.2 | ||
Siemens | N/A | Desigo CC Compact V4.1 toutes versions | ||
Siemens | N/A | APOGEE PXC Modular (BACnet) versions antérieures à V3.5.3 | ||
Siemens | N/A | SCALANCE XF204-2 (incl. SIPLUS NET variant) versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X204 IRT toutes versions | ||
Siemens | N/A | SIMATIC CP 343-1 ERPC toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX RX1510 versions antérieures à V2.14.1 | ||
Siemens | N/A | Cerberus DMS V4.1 toutes versions | ||
Siemens | N/A | Teamcenter Active Workspace V5.0 versions antérieures à V5.0.8 | ||
Siemens | N/A | SCALANCE X204-2LD TS versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X204-2LD (incl. SIPLUS NET variant) versions antérieures à V5.2.5 | ||
Siemens | N/A | SIPROTEC 5 relays with CPU variants CP100 versions antérieures à V8.80 | ||
Siemens | N/A | LOGO! CMR2040 versions antérieures à V2.2 | ||
Siemens | N/A | Desigo CC Compact V4.2 toutes versions | ||
Siemens | N/A | RUGGEDCOM ROX RX1536 versions antérieures à V2.14.1 | ||
Siemens | N/A | SCALANCE X208PRO versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X308-2M PoE toutes versions | ||
Siemens | N/A | SCALANCE X206-1LD versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X208 (incl. SIPLUS NET variant) versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X216 versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X206-1 versions antérieures à V5.2.5 | ||
Siemens | N/A | SCALANCE X212-2LD versions antérieures à V5.2.5 | ||
Siemens | N/A | Teamcenter Active Workspace V5.1 versions antérieures à V5.1.5 | ||
Siemens | N/A | SCALANCE X308-2 (incl. SIPLUS NET variant) toutes versions |
Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Industrial Edge Management versions ant\u00e9rieures \u00e0 V1.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC RF350M toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPROTEC 5 relays with CPU variants CP050 versions ant\u00e9rieures \u00e0 V8.80", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204-2TS versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X306-1LD FE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TALON TC Modular (BACnet) versions ant\u00e9rieures \u00e0 V3.5.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1501 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X201-3P IRT PRO toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MBC (PPC) (P2 Ethernet) toutes versions \u003e= V2.6.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V12.4 versions ant\u00e9rieures \u00e0 V12.4.0.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X302-7 EEC toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC V4.0 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X304-2FE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Modular (P2 Ethernet) toutes versions \u003e= V2.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MEC (PPC) (P2 Ethernet) toutes versions \u003e= V2.6.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEC NMS versions ant\u00e9rieures \u00e0 V1.0 SP1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2 IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 1543-1 (incl. SIPLUS variants) versions ant\u00e9rieures \u00e0 V3.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPROTEC 5 relays with CPU variants CP300 versions ant\u00e9rieures \u00e0 V8.80", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2LD toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X212-2 (incl. SIPLUS NET variant) versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1524 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324-4M PoE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC toutes versions with OIS Extension Module", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Active Workspace V4.3 versions ant\u00e9rieures \u00e0 V4.3.10", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X310 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX5000 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2LH+ toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "NX 1980 Series versions ant\u00e9rieures \u00e0 V1984", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter STAR-CCM+ Viewer versions ant\u00e9rieures \u00e0 V2021.2.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204 IRT PRO toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324-12M toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Active Workspace V5.2 versions ant\u00e9rieures \u00e0 V5.2.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2M toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siveillance Control toutes versions with OIS running on Debian 9 or earlier", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1400 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X408-2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Compact (P2 Ethernet) toutes versions \u003e= V2.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2M TS toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Operation Scheduler toutes versions with OIS running on Debian 9 or earlier", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324-4M PoE TS toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC V4.1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC Compact V4.0 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1512 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter Femap V2020.2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204 IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC V4.2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V13.0 versions ant\u00e9rieures \u00e0 V13.0.0.7", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X201-3P IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF202-2P IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204-2BA IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF206-1 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF201-3P IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X307-3LD toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter Femap V2021.1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X307-3 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPROTEC 5 relays with CPU variants CP200 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC RF650M toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siveillance Control Pro toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X310FE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Cerberus DMS V5.0 versions ant\u00e9rieures \u00e0 v5.0 QU1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEMA Server versions ant\u00e9rieures \u00e0 V14 SP3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TALON TC Compact (BACnet) versions ant\u00e9rieures \u00e0 V3.5.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2P IRT (incl. SIPLUS NET variant) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Compact (BACnet) versions ant\u00e9rieures \u00e0 V3.5.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X224 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 343-1 (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324-12M TS toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Cerberus DMS V4.2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X320-1-2LD FE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC RTU 3000 family toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX MX5000 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V13.1 versions ant\u00e9rieures \u00e0 V13.1.0.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 1545-1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC Compact V5.0 versions ant\u00e9rieures \u00e0 V5.0 QU1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF208 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2LH toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204-2 (incl. SIPLUS NET variant) versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1511 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1500 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X200-4P IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V13.2 versions ant\u00e9rieures \u00e0 13.2.0.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR324-4M EEC toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC V5.0 versions ant\u00e9rieures \u00e0 V5.0 QU1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X307-2 EEC toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X320-1 FE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204-2FM versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "GMA-Manager toutes versions with OIS running on Debian 9 or earlier", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 443-1 (incl. SIPLUS variants) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X202-2P IRT PRO toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Cerberus DMS V4.0 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEMA Remote Connect Server versions ant\u00e9rieures \u00e0 V3.0 SP2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "LOGO! CMR2020 versions ant\u00e9rieures \u00e0 V2.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC Compact V4.1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Modular (BACnet) versions ant\u00e9rieures \u00e0 V3.5.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF204-2 (incl. SIPLUS NET variant) versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204 IRT toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC CP 343-1 ERPC toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1510 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Cerberus DMS V4.1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Active Workspace V5.0 versions ant\u00e9rieures \u00e0 V5.0.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204-2LD TS versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X204-2LD (incl. SIPLUS NET variant) versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIPROTEC 5 relays with CPU variants CP100 versions ant\u00e9rieures \u00e0 V8.80", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "LOGO! CMR2040 versions ant\u00e9rieures \u00e0 V2.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Desigo CC Compact V4.2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RUGGEDCOM ROX RX1536 versions ant\u00e9rieures \u00e0 V2.14.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X208PRO versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2M PoE toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X206-1LD versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X208 (incl. SIPLUS NET variant) versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X216 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X206-1 versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X212-2LD versions ant\u00e9rieures \u00e0 V5.2.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter Active Workspace V5.1 versions ant\u00e9rieures \u00e0 V5.1.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE X308-2 (incl. SIPLUS NET variant) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2021-37186", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37186" }, { "name": "CVE-2021-37190", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37190" }, { "name": "CVE-2021-40356", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40356" }, { "name": "CVE-2021-33716", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33716" }, { "name": "CVE-2021-37191", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37191" }, { "name": "CVE-2020-36478", "url": "https://www.cve.org/CVERecord?id=CVE-2020-36478" }, { "name": "CVE-2021-37193", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37193" }, { "name": "CVE-2020-7461", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7461" }, { "name": "CVE-2021-40354", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40354" }, { "name": "CVE-2021-40355", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40355" }, { "name": "CVE-2016-10011", "url": "https://www.cve.org/CVERecord?id=CVE-2016-10011" }, { "name": "CVE-2021-37201", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37201" }, { "name": "CVE-2021-25665", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25665" }, { "name": "CVE-2021-37202", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37202" }, { "name": "CVE-2021-33737", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33737" }, { "name": "CVE-2020-36475", "url": "https://www.cve.org/CVERecord?id=CVE-2020-36475" }, { "name": "CVE-2016-10708", "url": "https://www.cve.org/CVERecord?id=CVE-2016-10708" }, { "name": "CVE-2021-37175", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37175" }, { "name": "CVE-2021-37174", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37174" }, { "name": "CVE-2021-40357", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40357" }, { "name": "CVE-2021-33720", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33720" }, { "name": "CVE-2021-37203", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37203" }, { "name": "CVE-2021-37183", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37183" }, { "name": "CVE-2021-37184", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37184" }, { "name": "CVE-2021-37177", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37177" }, { "name": "CVE-2021-37173", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37173" }, { "name": "CVE-2021-37200", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37200" }, { "name": "CVE-2021-33719", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33719" }, { "name": "CVE-2021-37181", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37181" }, { "name": "CVE-2021-31891", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31891" }, { "name": "CVE-2021-37192", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37192" }, { "name": "CVE-2021-37206", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37206" }, { "name": "CVE-2021-37176", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37176" }, { "name": "CVE-2021-27391", "url": "https://www.cve.org/CVERecord?id=CVE-2021-27391" }, { "name": "CVE-2019-10941", "url": "https://www.cve.org/CVERecord?id=CVE-2019-10941" } ], "initial_release_date": "2021-09-15T00:00:00", "last_revision_date": "2021-09-15T00:00:00", "links": [], "reference": "CERTFR-2021-AVI-706", "revisions": [ { "description": "Version initiale", "revision_date": "2021-09-15T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" }, { "description": "\u00c9l\u00e9vation de privil\u00e8ges" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-847986 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-847986.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-549234 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549234.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-208530 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-288459 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-987403 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-987403.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-535380 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-535380.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-334944 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-334944.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-676336 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-676336.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-997732 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-997732.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-835377 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-835377.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-109294 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-109294.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-453715 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-453715.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-692317 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-692317.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-756638 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-316383 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-316383.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-330339 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-330339.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-500748 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-500748.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-535997 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-535997.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-150692 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-150692.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-413407 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413407.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-944498 du 14 septembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf" } ] }
gsd-2020-7461
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2020-7461", "description": "In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit.", "id": "GSD-2020-7461" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-7461" ], "details": "In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit.", "id": "GSD-2020-7461", "modified": "2023-12-13T01:21:51.383617Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "secteam@freebsd.org", "ID": "CVE-2020-7461", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "FreeBSD", "version": { "version_data": [ { "version_value": "FreeBSD 12.1-RELEASE before p9, 11.4-RELEASE before p3, 11.3-RELEASE before p13" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Heap-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc", "refsource": "MISC", "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p10:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p11:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p12:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p4:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p5:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p6:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p7:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p8:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.3:p9:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.4:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.4:p1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:11.4:p2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:12.1:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:12.1:p1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:12.1:p2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:12.1:p3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:12.1:p4:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:12.1:p5:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:12.1:p6:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:12.1:p7:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:freebsd:freebsd:12.1:p8:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf350m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf350m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf650m_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf650m:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "secteam@freebsd.org", "ID": "CVE-2020-7461" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-787" } ] } ] }, "references": { "reference_data": [ { "name": "https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.4 } }, "lastModifiedDate": "2021-09-16T16:03Z", "publishedDate": "2021-03-26T21:15Z" } } }
fkie_cve-2020-7461
Vulnerability from fkie_nvd
URL | Tags | ||
---|---|---|---|
secteam@freebsd.org | https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf | Third Party Advisory | |
secteam@freebsd.org | https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc | Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.3 | |
freebsd | freebsd | 11.4 | |
freebsd | freebsd | 11.4 | |
freebsd | freebsd | 11.4 | |
freebsd | freebsd | 12.1 | |
freebsd | freebsd | 12.1 | |
freebsd | freebsd | 12.1 | |
freebsd | freebsd | 12.1 | |
freebsd | freebsd | 12.1 | |
freebsd | freebsd | 12.1 | |
freebsd | freebsd | 12.1 | |
freebsd | freebsd | 12.1 | |
freebsd | freebsd | 12.1 | |
siemens | simatic_rf350m_firmware | * | |
siemens | simatic_rf350m | - | |
siemens | simatic_rf650m_firmware | * | |
siemens | simatic_rf650m | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:-:*:*:*:*:*:*", "matchCriteriaId": "F35957CE-AF9F-40CA-BDD1-FA6A0E73783F", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p1:*:*:*:*:*:*", "matchCriteriaId": "EA929713-B797-494A-853D-C121D9D69519", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p10:*:*:*:*:*:*", "matchCriteriaId": "B87AF171-95AC-4DDA-8D94-694F85638B46", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p11:*:*:*:*:*:*", "matchCriteriaId": "1CC8B031-41BB-4846-B092-7E4BC6F35D6B", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p12:*:*:*:*:*:*", "matchCriteriaId": "83E34012-BC9D-4F0C-AAE1-FE5767B4EED6", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p2:*:*:*:*:*:*", "matchCriteriaId": "3C3D8EDC-91D3-45B2-AC1D-EF4346D4A714", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p3:*:*:*:*:*:*", "matchCriteriaId": "EA5006FF-06A5-4D95-BF5B-29F26248D11F", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p4:*:*:*:*:*:*", "matchCriteriaId": "A705031B-FD63-4076-B92E-E826E11D7111", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p5:*:*:*:*:*:*", "matchCriteriaId": "11C1EFB1-68E5-45F4-A7E1-744574F290D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p6:*:*:*:*:*:*", "matchCriteriaId": "25F649A7-9265-4552-8934-BCE083363982", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p7:*:*:*:*:*:*", "matchCriteriaId": "F202C856-5B95-4796-AC4A-1F210E7BAB8F", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p8:*:*:*:*:*:*", "matchCriteriaId": "9419C866-C478-4CDE-A9A1-E592D8FF0933", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.3:p9:*:*:*:*:*:*", "matchCriteriaId": "2B6DFC23-A7A1-431A-9AD9-A820579F95F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.4:-:*:*:*:*:*:*", "matchCriteriaId": "4A865EA1-01D7-4E5A-9D13-80780F8A9D7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.4:p1:*:*:*:*:*:*", "matchCriteriaId": "9FCA6A72-2A72-45FD-A43D-B5BF7C329121", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:11.4:p2:*:*:*:*:*:*", "matchCriteriaId": "90F9B3CB-3B60-4AA8-9EAF-4F0BE7D27691", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.1:-:*:*:*:*:*:*", "matchCriteriaId": "BD730B6A-F123-4685-ACB3-4F20AAAB77F3", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.1:p1:*:*:*:*:*:*", "matchCriteriaId": "508150E3-2C0C-4EEB-BFC9-BB5CEB404C06", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.1:p2:*:*:*:*:*:*", "matchCriteriaId": "B5D692EF-A5D7-430E-91BA-4CD137343B66", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.1:p3:*:*:*:*:*:*", "matchCriteriaId": "D50C60A7-4C9F-4636-92E9-9F5B8B01BE5B", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.1:p4:*:*:*:*:*:*", "matchCriteriaId": "6C49F6C7-A740-42F4-93BB-512CBF334516", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.1:p5:*:*:*:*:*:*", "matchCriteriaId": "402740C4-5B55-423F-BAD2-F742E1E21ADC", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.1:p6:*:*:*:*:*:*", "matchCriteriaId": "9DCAA10A-C612-45E0-84B7-55897F49D65E", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.1:p7:*:*:*:*:*:*", "matchCriteriaId": "CB6258A5-8066-48B8-A417-09A1547DD57A", "vulnerable": true }, { "criteria": "cpe:2.3:o:freebsd:freebsd:12.1:p8:*:*:*:*:*:*", "matchCriteriaId": "6601C7C4-EC36-4EAA-90AC-D3156A2BF330", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf350m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B60EA5E-219D-44E8-800B-97AB739B5895", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf350m:-:*:*:*:*:*:*:*", "matchCriteriaId": "E4B5DF0A-2850-4BFA-B110-36F2BE323A28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf650m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0B1DF7FC-EE60-48EE-8301-B8BDED3FD33E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf650m:-:*:*:*:*:*:*:*", "matchCriteriaId": "7DAE6641-16B6-4B41-B170-DAB51DF5AEC2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In FreeBSD 12.1-STABLE before r365010, 11.4-STABLE before r365011, 12.1-RELEASE before p9, 11.4-RELEASE before p3, and 11.3-RELEASE before p13, dhclient(8) fails to handle certain malformed input related to handling of DHCP option 119 resulting a heap overflow. The heap overflow could in principle be exploited to achieve remote code execution. The affected process runs with reduced privileges in a Capsicum sandbox, limiting the immediate impact of an exploit." }, { "lang": "es", "value": "En FreeBSD versiones 12.1-STABLE anteriores a r365010, 11.4-STABLE anteriores a r365011, 12.1-RELEASE anteriores a p9, 11.4-RELEASE anteriores a p3 y 11.3-RELEASE anteriores a p13, dhclient(8) no puede manejar determinadas entradas malformadas relacionadas con el manejo de la opci\u00f3n 119 de DHCP resultando en un desbordamiento de la pila.\u0026#xa0;En principio, el desbordamiento de la pila podr\u00eda explotarse para lograr una ejecuci\u00f3n de c\u00f3digo remota.\u0026#xa0;El proceso afectado se ejecuta con privilegios reducidos en un sandbox Capsicum, limitando el impacto inmediato de una explotaci\u00f3n." } ], "id": "CVE-2020-7461", "lastModified": "2024-11-21T05:37:11.450", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-26T21:15:13.053", "references": [ { "source": "secteam@freebsd.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" }, { "source": "secteam@freebsd.org", "tags": [ "Vendor Advisory" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-288459.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-20:26.dhclient.asc" } ], "sourceIdentifier": "secteam@freebsd.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cnvd-2021-29082
Vulnerability from cnvd
厂商已发布了漏洞修复程序,请及时关注更新: https://www.cybersecurity-help.cz/vdb/SB2020090303
Name | ['FreeBSD Freebsd 12.1-STABLE,<r365010', 'FreeBSD Freebsd 11.4-STABLE,<r365011', 'FreeBSD Freebsd 12.1-RELEASE,<p9', 'FreeBSD Freebsd 11.4-RELEASE,<p3', 'FreeBSD Freebsd 11.3-RELEASE,<p13'] |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2020-7461", "cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2020-7461" } }, "description": "FreeBSD\u662fFreeBSD\u57fa\u91d1\u4f1a\u7684\u4e00\u5957\u7c7bUnix\u64cd\u4f5c\u7cfb\u7edf\u3002\n\nFreeBSD\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u901a\u8fc7Dhclient Option 119\u89e6\u53d1\u62d2\u7edd\u670d\u52a1\u5e76\u4ee3\u7801\u6267\u884c\u3002", "formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://www.cybersecurity-help.cz/vdb/SB2020090303", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2021-29082", "openTime": "2021-04-18", "patchDescription": "FreeBSD\u662fFreeBSD\u57fa\u91d1\u4f1a\u7684\u4e00\u5957\u7c7bUnix\u64cd\u4f5c\u7cfb\u7edf\u3002\r\n\r\nFreeBSD\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u901a\u8fc7Dhclient Option 119\u89e6\u53d1\u62d2\u7edd\u670d\u52a1\u5e76\u4ee3\u7801\u6267\u884c\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "FreeBSD\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2021-29082\uff09\u7684\u8865\u4e01", "products": { "product": [ "FreeBSD Freebsd 12.1-STABLE\uff0c\u003cr365010", "FreeBSD Freebsd 11.4-STABLE\uff0c\u003cr365011", "FreeBSD Freebsd 12.1-RELEASE\uff0c\u003cp9", "FreeBSD Freebsd 11.4-RELEASE\uff0c\u003cp3", "FreeBSD Freebsd 11.3-RELEASE\uff0c\u003cp13" ] }, "referenceLink": "https://vigilance.fr/vulnerability/FreeBSD-buffer-overflow-via-Dhclient-Option-119-33238", "serverity": "\u9ad8", "submitTime": "2020-09-04", "title": "FreeBSD\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2021-29082\uff09" }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.