- Denial-of-service (DoS) and malware execution
Summary
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors.
References
| URL | Tags | ||
|---|---|---|---|
|
|
|||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Mitsubishi Electric Corporation | Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 |
Version: MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:30:24.566Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2019-003_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95424547/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Denial-of-service (DoS) and malware execution",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-17T06:55:15",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2019-003_en.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95424547/index.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2020-5531",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000",
"version": {
"version_data": [
{
"version_value": "MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before)"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Denial-of-service (DoS) and malware execution"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2019-003_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2019-003_en.pdf"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95424547/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95424547/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2020-5531",
"datePublished": "2020-02-17T06:55:15",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:30:24.566Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2020-5531\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2020-02-17T07:15:16.473\",\"lastModified\":\"2024-11-21T05:34:13.560\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors.\"},{\"lang\":\"es\",\"value\":\"Mitsubishi Electric MELSEC C Controller Module y MELIPC Series MI5000 MELSEC-Q Series C Controller Module (Q24DHCCPU-V, Q24DHCCPU-VG puerto User Ethernet (CH1, CH2): Primeros 5 d\u00edgitos del n\u00famero de serial 21121 o anterior), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module (R12CCPU-V puerto Ethernet (CH1, CH2): Primeros 2 d\u00edgitos del n\u00famero de serial 11 o anterior, y RD55UP06-V puerto Ethernet: Primeros 2 d\u00edgitos del n\u00famero de serial 08 o anterior), y MELIPC Series MI5000 (MI5122-VW puerto Ethernet (CH1): Primeros 2 d\u00edgitos del n\u00famero de serial 03 o anterior, o la versi\u00f3n de firmware 03 o anterior), permite a atacantes remotos causar una denegaci\u00f3n de servicio (DoS) y/o un malware que se ejecuta por medio de vectores no especificados.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:mi5122-vw_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"03\",\"matchCriteriaId\":\"66A9D45E-95CE-42C0-B7BA-00A2402DE65C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:mi5122-vw:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2054E9BB-9DC6-49DA-A215-D63A93B8160C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:q24dhccpu-v_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"21121\",\"matchCriteriaId\":\"E2ED90B7-7987-4C00-8D17-1F8C277A1CBA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:q24dhccpu-v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"210A2E8A-BF20-43F5-BA07-CB662833DE1D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:q24dhccpu-vg_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"21121\",\"matchCriteriaId\":\"3C71A2CB-E456-4BA5-A845-5B1D036E3D50\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:q24dhccpu-vg:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D9DF6F77-EEB5-4CB3-B041-7BA43F16E2E3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:r12ccpu-v_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"11\",\"matchCriteriaId\":\"3BF5934E-7FAD-410F-AB75-FA7BACB345DC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:r12ccpu-v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B938943-DDD5-43DC-98A3-29D0E6AFBF85\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:rd55up06-v_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"08\",\"matchCriteriaId\":\"29ED1F7F-AC02-418F-A380-6FFF2C0FB6A3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:rd55up06-v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F1F5EF13-A273-459E-815B-F21C57D44204\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/en/vu/JVNVU95424547/index.html\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2019-003_en.pdf\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://jvn.jp/en/vu/JVNVU95424547/index.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2019-003_en.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…