var-202002-1038
Vulnerability from variot
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors. Provided by Mitsubishi Electric Corporation MELSEC C Language controller unit and MELIPC series MI5000 In Wind River Company real-time OS Is VxWorks of TCP/IP Network stack (IPnet) The following vulnerabilities discovered in ( Known as " URGENT/11 " ) There are multiple vulnerabilities due to. * Q24DHCCPU-V and Q24DHCCPU-VG Buffer error (CWE-119) - CVE-2019-12255 Buffer error (CWE-119) - CVE-2019-12257 Session fixation (CWE-384) - CVE-2019-12258 NULL Pointer dereferencing (CWE-476) - CVE-2019-12259 Buffer error (CWE-119) - CVE-2019-12261 Improper access control (CWE-284) - CVE-2019-12262 Buffer error (CWE-119) - CVE-2019-12263 Insert or change arguments (CWE-88) - CVE-2019-12264 Resource management issues (CWE-399) - CVE-2019-12265 R12CCPU-V and RD55UP06-V Buffer error (CWE-119) - CVE-2019-12256 Session fixation (CWE-384) - CVE-2019-12258 NULL Pointer dereferencing (CWE-476) - CVE-2019-12259 Buffer error (CWE-119) - CVE-2019-12261 Improper access control (CWE-284) - CVE-2019-12262 Buffer error (CWE-119) - CVE-2019-12263 Insert or change arguments (CWE-88) - CVE-2019-12264 Resource management issues (CWE-399) - CVE-2019-12265 MI5122-VW Buffer error (CWE-119) - CVE-2019-12256 Session fixation (CWE-384) - CVE-2019-12258 NULL Pointer dereferencing (CWE-476) - CVE-2019-12259 Buffer error (CWE-119) - CVE-2019-12260 Buffer error (CWE-119) - CVE-2019-12261 Improper access control (CWE-284) - CVE-2019-12262 Buffer error (CWE-119) - CVE-2019-12263 Insert or change arguments (CWE-88) - CVE-2019-12264 Resource management issues (CWE-399) - CVE-2019-12265Crafted by a remote third party TCP Receiving the packet may cause the product service to stop or the malware to be executed. Mitsubishi Electric MELSEC-Q Series is a programmable logic controller of MELSEC-Q series.
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 TCP / IP functions have security holes. A remote attacker could use this vulnerability to cause a denial of service and / or run malware
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202002-1038",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "q24dhccpu-vg",
"scope": "lte",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "21121"
},
{
"model": "mi5122-vw",
"scope": "lte",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "03"
},
{
"model": "r12ccpu-v",
"scope": "lte",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "11"
},
{
"model": "q24dhccpu-v",
"scope": "lte",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "21121"
},
{
"model": "rd55up06-v",
"scope": "lte",
"trust": 1.0,
"vendor": "mitsubishielectric",
"version": "08"
},
{
"model": "melsec-q \u30b7\u30ea\u30fc\u30ba c\u8a00\u8a9e\u30b3\u30f3\u30c8\u30ed\u30fc\u30e9\u30e6\u30cb\u30c3\u30c8",
"scope": "eq",
"trust": 0.8,
"vendor": "\u4e09\u83f1\u96fb\u6a5f",
"version": "first 5 digits of serial number are 21121 or before"
},
{
"model": "melsec iq-r \u30b7\u30ea\u30fc\u30ba c\u8a00\u8a9e\u30b3\u30f3\u30c8\u30ed\u30fc\u30e9\u30e6\u30cb\u30c3\u30c8",
"scope": "eq",
"trust": 0.8,
"vendor": "\u4e09\u83f1\u96fb\u6a5f",
"version": "first 2 digits of serial number are 08 or before"
},
{
"model": "melsec iq-r \u30b7\u30ea\u30fc\u30ba c\u8a00\u8a9e\u30a4\u30f3\u30c6\u30ea\u30b8\u30a7\u30f3\u30c8\u6a5f\u80fd\u30e6\u30cb\u30c3\u30c8",
"scope": "eq",
"trust": 0.8,
"vendor": "\u4e09\u83f1\u96fb\u6a5f",
"version": "first 2 digits of serial number are 11 or before"
},
{
"model": "melsec iq-r \u30b7\u30ea\u30fc\u30ba c\u8a00\u8a9e\u30a4\u30f3\u30c6\u30ea\u30b8\u30a7\u30f3\u30c8\u6a5f\u80fd\u30e6\u30cb\u30c3\u30c8",
"scope": "eq",
"trust": 0.8,
"vendor": "\u4e09\u83f1\u96fb\u6a5f",
"version": "first 2 digits of serial number are 08 or before"
},
{
"model": "melipc \u30b7\u30ea\u30fc\u30ba mi5000",
"scope": "eq",
"trust": 0.8,
"vendor": "\u4e09\u83f1\u96fb\u6a5f",
"version": "the first two digits of the serial number are \u201c03\u201d or less, or the firmware version is \u201c03\u201d or less"
},
{
"model": "melsec iq-r \u30b7\u30ea\u30fc\u30ba c\u8a00\u8a9e\u30b3\u30f3\u30c8\u30ed\u30fc\u30e9\u30e6\u30cb\u30c3\u30c8",
"scope": "eq",
"trust": 0.8,
"vendor": "\u4e09\u83f1\u96fb\u6a5f",
"version": "first 2 digits of serial number are 11 or before"
},
{
"model": "electric q24dhccpu-v user ethernet port",
"scope": null,
"trust": 0.6,
"vendor": "mitsubishi",
"version": null
},
{
"model": "electric 24dhccpu-vg user ethernet port",
"scope": null,
"trust": 0.6,
"vendor": "mitsubishi",
"version": null
},
{
"model": "electric r12ccpu-v ethernet port",
"scope": null,
"trust": 0.6,
"vendor": "mitsubishi",
"version": null
},
{
"model": "electric rd55up06-v ethernet port",
"scope": null,
"trust": 0.6,
"vendor": "mitsubishi",
"version": null
},
{
"model": "electric mi5122-vw ethernet port",
"scope": null,
"trust": 0.6,
"vendor": "mitsubishi",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "mi5122 vw",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "q24dhccpu v",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "q24dhccpu vg",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "r12ccpu v",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "rd55up06 v",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "b68d141b-8812-49a8-820f-878c70d9f9e5"
},
{
"db": "CNVD",
"id": "CNVD-2020-13174"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-001591"
},
{
"db": "NVD",
"id": "CVE-2020-5531"
}
]
},
"cve": "CVE-2020-5531",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-5531",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-13174",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "b68d141b-8812-49a8-820f-878c70d9f9e5",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2020-5531",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-5531",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2020-13174",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202002-848",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "IVD",
"id": "b68d141b-8812-49a8-820f-878c70d9f9e5",
"trust": 0.2,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "b68d141b-8812-49a8-820f-878c70d9f9e5"
},
{
"db": "CNVD",
"id": "CNVD-2020-13174"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-848"
},
{
"db": "NVD",
"id": "CVE-2020-5531"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors. Provided by Mitsubishi Electric Corporation MELSEC C Language controller unit and MELIPC series MI5000 In Wind River Company real-time OS Is VxWorks of TCP/IP Network stack (IPnet) The following vulnerabilities discovered in ( Known as \" URGENT/11 \" ) There are multiple vulnerabilities due to. * Q24DHCCPU-V and Q24DHCCPU-VG* Buffer error (CWE-119) - CVE-2019-12255* Buffer error (CWE-119) - CVE-2019-12257* Session fixation (CWE-384) - CVE-2019-12258* NULL Pointer dereferencing (CWE-476) - CVE-2019-12259* Buffer error (CWE-119) - CVE-2019-12261* Improper access control (CWE-284) - CVE-2019-12262* Buffer error (CWE-119) - CVE-2019-12263* Insert or change arguments (CWE-88) - CVE-2019-12264* Resource management issues (CWE-399) - CVE-2019-12265* R12CCPU-V and RD55UP06-V* Buffer error (CWE-119) - CVE-2019-12256* Session fixation (CWE-384) - CVE-2019-12258* NULL Pointer dereferencing (CWE-476) - CVE-2019-12259* Buffer error (CWE-119) - CVE-2019-12261* Improper access control (CWE-284) - CVE-2019-12262* Buffer error (CWE-119) - CVE-2019-12263* Insert or change arguments (CWE-88) - CVE-2019-12264* Resource management issues (CWE-399) - CVE-2019-12265* MI5122-VW* Buffer error (CWE-119) - CVE-2019-12256* Session fixation (CWE-384) - CVE-2019-12258* NULL Pointer dereferencing (CWE-476) - CVE-2019-12259* Buffer error (CWE-119) - CVE-2019-12260* Buffer error (CWE-119) - CVE-2019-12261* Improper access control (CWE-284) - CVE-2019-12262* Buffer error (CWE-119) - CVE-2019-12263* Insert or change arguments (CWE-88) - CVE-2019-12264* Resource management issues (CWE-399) - CVE-2019-12265Crafted by a remote third party TCP Receiving the packet may cause the product service to stop or the malware to be executed. Mitsubishi Electric MELSEC-Q Series is a programmable logic controller of MELSEC-Q series. \n\r\n\r\nMitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 TCP / IP functions have security holes. A remote attacker could use this vulnerability to cause a denial of service and / or run malware",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-5531"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-001591"
},
{
"db": "CNVD",
"id": "CNVD-2020-13174"
},
{
"db": "IVD",
"id": "b68d141b-8812-49a8-820f-878c70d9f9e5"
}
],
"trust": 2.34
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-5531",
"trust": 3.2
},
{
"db": "JVN",
"id": "JVNVU95424547",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2020-001591",
"trust": 2.0
},
{
"db": "CNVD",
"id": "CNVD-2020-13174",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202002-848",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-19-274-01",
"trust": 0.8
},
{
"db": "IVD",
"id": "B68D141B-8812-49A8-820F-878C70D9F9E5",
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "b68d141b-8812-49a8-820f-878c70d9f9e5"
},
{
"db": "CNVD",
"id": "CNVD-2020-13174"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-001591"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-848"
},
{
"db": "NVD",
"id": "CVE-2020-5531"
}
]
},
"id": "VAR-202002-1038",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "b68d141b-8812-49a8-820f-878c70d9f9e5"
},
{
"db": "CNVD",
"id": "CNVD-2020-13174"
}
],
"trust": 1.74444445
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
},
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "b68d141b-8812-49a8-820f-878c70d9f9e5"
},
{
"db": "CNVD",
"id": "CNVD-2020-13174"
}
]
},
"last_update_date": "2024-11-23T21:02:43.771000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "MELSEC\u00a0C Language controller unit and MELIPC\u00a0 series MI5000 of TCP/IP Multiple vulnerabilities in features",
"trust": 0.8,
"url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2019-003.pdf"
},
{
"title": "Patch for Unknown vulnerability in Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 TCP / IP functions",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/204581"
},
{
"title": "Multiple Mitsubishi Electric Product security vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=111196"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-13174"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-001591"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-848"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-5531"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2019-003_en.pdf"
},
{
"trust": 1.6,
"url": "https://jvn.jp/en/vu/jvnvu95424547/index.html"
},
{
"trust": 1.2,
"url": "https://jvndb.jvn.jp/en/contents/2020/jvndb-2020-001591.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu95424547/"
},
{
"trust": 0.8,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-274-01"
},
{
"trust": 0.8,
"url": "https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-5531"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-13174"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-001591"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-848"
},
{
"db": "NVD",
"id": "CVE-2020-5531"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "b68d141b-8812-49a8-820f-878c70d9f9e5"
},
{
"db": "CNVD",
"id": "CNVD-2020-13174"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-001591"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-848"
},
{
"db": "NVD",
"id": "CVE-2020-5531"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-02-17T00:00:00",
"db": "IVD",
"id": "b68d141b-8812-49a8-820f-878c70d9f9e5"
},
{
"date": "2020-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-13174"
},
{
"date": "2020-02-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-001591"
},
{
"date": "2020-02-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202002-848"
},
{
"date": "2020-02-17T07:15:16.473000",
"db": "NVD",
"id": "CVE-2020-5531"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-02-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-13174"
},
{
"date": "2020-02-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-001591"
},
{
"date": "2023-05-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202002-848"
},
{
"date": "2024-11-21T05:34:13.560000",
"db": "NVD",
"id": "CVE-2020-5531"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202002-848"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mitsubishi Electric \u00a0MELSEC\u00a0C Language controller unit and \u00a0MELIPC\u00a0 series \u00a0MI5000\u00a0 Multiple vulnerabilities in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-001591"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "IVD",
"id": "b68d141b-8812-49a8-820f-878c70d9f9e5"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-848"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.