CVE-2020-11643 (GCVE-0-2020-11643)

Vulnerability from cvelistv5 – Published: 2020-10-15 14:57 – Updated: 2024-09-17 02:41
VLAI
Title
GateManager Information Disclosure Vulnerability
Summary
An information disclosure vulnerability in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to view information of devices belonging to foreign domains.
CWE
  • CWE-532 - Information Exposure Through Log Files
Impacted products
Vendor Product Version CPE status
B&R GateManager Affected: 4260 , < 9.0.20262 (custom)
Affected: 9250 , < 9.0.20262 (custom)
Affected: 8250 , < 9.2.620236042 (custom)
guessed Create a notification for this product.
Date Public
2020-09-29 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:35:13.611Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GateManager",
          "vendor": "B\u0026R",
          "versions": [
            {
              "lessThan": "9.0.20262",
              "status": "affected",
              "version": "4260",
              "versionType": "custom"
            },
            {
              "lessThan": "9.0.20262",
              "status": "affected",
              "version": "9250",
              "versionType": "custom"
            },
            {
              "lessThan": "9.2.620236042",
              "status": "affected",
              "version": "8250",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-09-29T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An information disclosure vulnerability in B\u0026R GateManager 4260 and 9250 versions \u003c9.0.20262 and GateManager 8250 versions \u003c9.2.620236042 allows authenticated users to view information of devices belonging to foreign domains."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Information Exposure Through Log Files",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-11-17T01:34:39.000Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "GateManager Information Disclosure Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "DATE_PUBLIC": "2020-09-29T00:00:00.000Z",
          "ID": "CVE-2020-11643",
          "STATE": "PUBLIC",
          "TITLE": "GateManager Information Disclosure Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "GateManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "4260",
                            "version_value": "9.0.20262"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "9250",
                            "version_value": "9.0.20262"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "8250",
                            "version_value": "9.2.620236042"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "B\u0026R"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An information disclosure vulnerability in B\u0026R GateManager 4260 and 9250 versions \u003c9.0.20262 and GateManager 8250 versions \u003c9.2.620236042 allows authenticated users to view information of devices belonging to foreign domains."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-532 Information Exposure Through Log Files"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf",
              "refsource": "MISC",
              "url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf"
            },
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2020-11643",
    "datePublished": "2020-10-15T14:57:22.323Z",
    "dateReserved": "2020-04-08T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:41:20.734Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-11643",
      "date": "2026-09-28",
      "epss": "0.01285",
      "percentile": "0.68974"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:br-automation:gatemanager_9250_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CA294ABA-2C18-4EC7-95B2-E0BC4EAA4D5C",
                  "versionEndExcluding": "9.0.20262",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:br-automation:gatemanager_9250:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0B280165-5A6D-481E-A491-D16749CD45FA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:br-automation:gatemanager_4260_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "72CD9ABC-BCA3-453D-A26F-3C61237C9C1C",
                  "versionEndExcluding": "9.0.20262",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:br-automation:gatemanager_4260:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "58B4D4A1-54AB-4849-A1F5-3CDB42FF0712",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:br-automation:gatemanager_8250_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "06AB955E-3951-4B3E-8B9D-E5A987FDFBCE",
                  "versionEndExcluding": "9.2.620236042",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:br-automation:gatemanager_8250:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FBA1D46A-4C8F-4A1B-8708-A8F488287643",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An information disclosure vulnerability in B\u0026R GateManager 4260 and 9250 versions \u003c9.0.20262 and GateManager 8250 versions \u003c9.2.620236042 allows authenticated users to view information of devices belonging to foreign domains."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en B\u0026amp;R GateManager 4260 y 9250 versiones anteriores a 9.0.20262 y GateManager 8250 versiones anteriores a 9.2.620236042, permite a usuarios autenticados visualizar informaci\u00f3n de dispositivos que pertenecen a dominios externos"
        }
      ],
      "id": "CVE-2020-11643",
      "lastModified": "2024-11-21T04:58:18.660",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "cybersecurity@ch.abb.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-10-15T15:15:10.953",
      "references": [
        {
          "source": "cybersecurity@ch.abb.com",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03"
        },
        {
          "source": "cybersecurity@ch.abb.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf"
        }
      ],
      "sourceIdentifier": "cybersecurity@ch.abb.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-532"
            }
          ],
          "source": "cybersecurity@ch.abb.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-532"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:br-automation:gatemanager_9250_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CA294ABA-2C18-4EC7-95B2-E0BC4EAA4D5C",
                    "versionEndExcluding": "9.0.20262",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:br-automation:gatemanager_9250:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0B280165-5A6D-481E-A491-D16749CD45FA",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:br-automation:gatemanager_4260_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "72CD9ABC-BCA3-453D-A26F-3C61237C9C1C",
                    "versionEndExcluding": "9.0.20262",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:br-automation:gatemanager_4260:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "58B4D4A1-54AB-4849-A1F5-3CDB42FF0712",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:br-automation:gatemanager_8250_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "06AB955E-3951-4B3E-8B9D-E5A987FDFBCE",
                    "versionEndExcluding": "9.2.620236042",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:br-automation:gatemanager_8250:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FBA1D46A-4C8F-4A1B-8708-A8F488287643",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An information disclosure vulnerability in B\u0026R GateManager 4260 and 9250 versions \u003c9.0.20262 and GateManager 8250 versions \u003c9.2.620236042 allows authenticated users to view information of devices belonging to foreign domains."
          },
          {
            "lang": "es",
            "value": "Una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en B\u0026amp;R GateManager 4260 y 9250 versiones anteriores a 9.0.20262 y GateManager 8250 versiones anteriores a 9.2.620236042, permite a usuarios autenticados visualizar informaci\u00f3n de dispositivos que pertenecen a dominios externos"
          }
        ],
        "id": "CVE-2020-11643",
        "lastModified": "2024-11-21T04:58:18.660",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "NONE",
                "baseScore": 4.0,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 3.6,
              "source": "cybersecurity@ch.abb.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2020-10-15T15:15:10.953",
        "references": [
          {
            "source": "cybersecurity@ch.abb.com",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03"
          },
          {
            "source": "cybersecurity@ch.abb.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf"
          }
        ],
        "sourceIdentifier": "cybersecurity@ch.abb.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-532"
              }
            ],
            "source": "cybersecurity@ch.abb.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-532"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…