Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2019-10925 (GCVE-0-2019-10925)
Vulnerability from cvelistv5
- CWE-284 - Improper Access Control
| URL | Tags | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | SIMATIC MV400 family |
Version: All Versions < V7.0.6 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.426Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "108725",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108725"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC MV400 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V7.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-15T17:03:29",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "108725",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108725"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10925",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC MV400 family",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c V7.0.6"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "108725",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108725"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10925",
"datePublished": "2019-06-12T13:47:56",
"dateReserved": "2019-04-08T00:00:00",
"dateUpdated": "2024-08-04T22:40:15.426Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2019-10925\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-06-12T14:29:04.477\",\"lastModified\":\"2024-11-21T04:20:09.977\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad ha sido identificada en la familia SIMATIC MV400 family (Todas las versiones anteriores a V7.0.6). Un atacante identificado podr\u00eda escalar sus privilegios mediante el env\u00edo de peticiones especialmente creadas al servidor web integrado. La vulnerabilidad de la seguridad puede ser aprovechada por un atacante con acceso de red al dispositivo. Credenciales de usuario v\u00e1lidas, pero no se requiere la interacci\u00f3n del usuario. La operaci\u00f3n con \u00e9xito compromete la integridad y la disponibilidad del dispositivo. En el momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":4.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:N/I:P/A:P\",\"baseScore\":5.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv420_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C802EF05-03DD-4BE0-ACDA-8BDA11EA6D25\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv420:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"79B15C1B-2510-434B-A589-5903CA0C00EE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv440_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0B53B628-F96C-40B1-A952-659406759472\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv440:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6408042E-7E06-4AED-9853-29B176EDFE9F\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/108725\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.securityfocus.com/bid/108725\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
fkie_cve-2019-10925
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | http://www.securityfocus.com/bid/108725 | Third Party Advisory, VDB Entry | |
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf | Mitigation, Vendor Advisory | |
| productcert@siemens.com | https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/108725 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02 | Third Party Advisory, US Government Resource |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | simatic_mv420_firmware | * | |
| siemens | simatic_mv420 | - | |
| siemens | simatic_mv440_firmware | * | |
| siemens | simatic_mv440 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_mv420_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C802EF05-03DD-4BE0-ACDA-8BDA11EA6D25",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_mv420:-:*:*:*:*:*:*:*",
"matchCriteriaId": "79B15C1B-2510-434B-A589-5903CA0C00EE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_mv440_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0B53B628-F96C-40B1-A952-659406759472",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_mv440:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6408042E-7E06-4AED-9853-29B176EDFE9F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
},
{
"lang": "es",
"value": "Una vulnerabilidad ha sido identificada en la familia SIMATIC MV400 family (Todas las versiones anteriores a V7.0.6). Un atacante identificado podr\u00eda escalar sus privilegios mediante el env\u00edo de peticiones especialmente creadas al servidor web integrado. La vulnerabilidad de la seguridad puede ser aprovechada por un atacante con acceso de red al dispositivo. Credenciales de usuario v\u00e1lidas, pero no se requiere la interacci\u00f3n del usuario. La operaci\u00f3n con \u00e9xito compromete la integridad y la disponibilidad del dispositivo. En el momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad"
}
],
"id": "CVE-2019-10925",
"lastModified": "2024-11-21T04:20:09.977",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 4.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-06-12T14:29:04.477",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/108725"
},
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/108725"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-284"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
ICSA-19-162-02
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from a Siemens ProductCERT\u0027s advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-816980: Multiple Web Vulnerabilities in SIMATIC MV400 Family - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-816980.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-162-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-162-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-162-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-162-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC Ident MV440 Family (Update A)",
"tracking": {
"current_release_date": "2021-03-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-19-162-02",
"initial_release_date": "2019-06-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-06-11T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2021-03-09T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added update information for MV400"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV7.0.6",
"product": {
"name": "Siemens SIMATIC MV400 family: All Versions \u003c V7.0.6",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC MV400 family"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-10925",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "By setting the DISA bit, changes to the project by logged-in users can be prevented. Please refer to the Operating Instructions for more details: https://support.industry.siemens.com/cs/ww/en/view/84553392",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Protect network access to affected devices.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V7.0.6 https://support.industry.siemens.com/cs/ww/en/view/109793481/",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2019-10925"
},
{
"cve": "CVE-2019-10926",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "By setting the DISA bit, changes to the project by logged-in users can be prevented. Please refer to the Operating Instructions for more details: https://support.industry.siemens.com/cs/ww/en/view/84553392",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Protect network access to affected devices.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V7.0.6 https://support.industry.siemens.com/cs/ww/en/view/109793481/",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2019-10926"
}
]
}
icsa-19-162-02
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from a Siemens ProductCERT\u0027s advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-816980: Multiple Web Vulnerabilities in SIMATIC MV400 Family - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-816980.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-162-02 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-162-02.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-162-02 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-162-02"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC Ident MV440 Family (Update A)",
"tracking": {
"current_release_date": "2021-03-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-19-162-02",
"initial_release_date": "2019-06-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-06-11T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2021-03-09T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added update information for MV400"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV7.0.6",
"product": {
"name": "Siemens SIMATIC MV400 family: All Versions \u003c V7.0.6",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC MV400 family"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-10925",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "By setting the DISA bit, changes to the project by logged-in users can be prevented. Please refer to the Operating Instructions for more details: https://support.industry.siemens.com/cs/ww/en/view/84553392",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Protect network access to affected devices.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V7.0.6 https://support.industry.siemens.com/cs/ww/en/view/109793481/",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2019-10925"
},
{
"cve": "CVE-2019-10926",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "By setting the DISA bit, changes to the project by logged-in users can be prevented. Please refer to the Operating Instructions for more details: https://support.industry.siemens.com/cs/ww/en/view/84553392",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Protect network access to affected devices.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V7.0.6 https://support.industry.siemens.com/cs/ww/en/view/109793481/",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2019-10926"
}
]
}
CERTFR-2021-AVI-176
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SENTRON PAC3200 versions antérieures à 2.4.7 | ||
| Siemens | N/A | SENTRON 3VA COM100/800, 3VA DSP800, PAC2200 toutes versions | ||
| Siemens | N/A | SCALANCE XM400 et XR500 versions antérieures à 6.2 | ||
| Siemens | N/A | SIMATIC S7-PLCSIM version 5.4 | ||
| Siemens | N/A | RUGGEDCOM RM1224, SCALANCE M-800 et Scalance S615 versions 4.3 et ultérieures | ||
| Siemens | N/A | SENTRON PAC3220 versions antérieures à 3.2.0 | ||
| Siemens | N/A | module Mendix Forgot Password versions antérieures à 3.2.1 | ||
| Siemens | N/A | SIMATIC NET CM 1542-1 toutes versions | ||
| Siemens | N/A | Solid Edge SE2020 versions antérieures à SE2020MP13 | ||
| Siemens | N/A | SINEMA remote connect server versions antérieures à 3.0 | ||
| Siemens | N/A | SCALANCE SC-600 versions antérieures à 2.1.3 | ||
| Siemens | N/A | LOGO! 8 BM toutes versions (y compris les versions SIPLUS) | ||
| Siemens | N/A | PLUSCONTROL 1st Gen toutes versions | ||
| Siemens | N/A | SENTRON PAC4200 versions antérieures à 2.3.0 | ||
| Siemens | N/A | Luxion KeyShot versions antérieures à 10.1 | ||
| Siemens | N/A | SCALANCE X300WG et Xx200 versions antérieures à 4.1 | ||
| Siemens | N/A | SIMATIC MV400 versions antérieures à 7.0.6 | ||
| Siemens | N/A | Solid Edge SE2021 versions antérieures à SE2021MP3 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SENTRON PAC3200 versions ant\u00e9rieures \u00e0 2.4.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON 3VA COM100/800, 3VA DSP800, PAC2200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM400 et XR500 versions ant\u00e9rieures \u00e0 6.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-PLCSIM version 5.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RM1224, SCALANCE M-800 et Scalance S615 versions 4.3 et ult\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON PAC3220 versions ant\u00e9rieures \u00e0 3.2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "module Mendix Forgot Password versions ant\u00e9rieures \u00e0 3.2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CM 1542-1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2020 versions ant\u00e9rieures \u00e0 SE2020MP13",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA remote connect server versions ant\u00e9rieures \u00e0 3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC-600 versions ant\u00e9rieures \u00e0 2.1.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO! 8 BM toutes versions (y compris les versions SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PLUSCONTROL 1st Gen toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON PAC4200 versions ant\u00e9rieures \u00e0 2.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Luxion KeyShot versions ant\u00e9rieures \u00e0 10.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X300WG et Xx200 versions ant\u00e9rieures \u00e0 4.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV400 versions ant\u00e9rieures \u00e0 7.0.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2021 versions ant\u00e9rieures \u00e0 SE2021MP3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-25667",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25667"
},
{
"name": "CVE-2020-28388",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28388"
},
{
"name": "CVE-2021-27381",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27381"
},
{
"name": "CVE-2021-25673",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25673"
},
{
"name": "CVE-2020-28387",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28387"
},
{
"name": "CVE-2020-25241",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25241"
},
{
"name": "CVE-2021-22647",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22647"
},
{
"name": "CVE-2021-22643",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22643"
},
{
"name": "CVE-2021-25672",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25672"
},
{
"name": "CVE-2021-27380",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27380"
},
{
"name": "CVE-2021-22649",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22649"
},
{
"name": "CVE-2021-22651",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22651"
},
{
"name": "CVE-2021-25676",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25676"
},
{
"name": "CVE-2021-25674",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25674"
},
{
"name": "CVE-2021-22645",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22645"
},
{
"name": "CVE-2019-3823",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-3823"
},
{
"name": "CVE-2020-28385",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28385"
},
{
"name": "CVE-2019-10926",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10926"
},
{
"name": "CVE-2020-13987",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13987"
},
{
"name": "CVE-2020-27632",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27632"
},
{
"name": "CVE-2020-25239",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25239"
},
{
"name": "CVE-2020-25236",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25236"
},
{
"name": "CVE-2021-25675",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25675"
},
{
"name": "CVE-2020-25240",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25240"
},
{
"name": "CVE-2019-10925",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10925"
},
{
"name": "CVE-2020-17437",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-17437"
}
],
"initial_release_date": "2021-03-10T00:00:00",
"last_revision_date": "2021-03-10T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-176",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-03-10T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-599268 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599268.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-979775 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-541018 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-715184 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-936080 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-936080.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-231216 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-231216.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-783481 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-296266 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-296266.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-731317 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731317.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-256092 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-344238 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-917115 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917115.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-816980 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
}
]
}
CERTFR-2019-AVI-256
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC Ident MV420 | ||
| Siemens | N/A | SIEMENS LOGO!8 versions antérieures à V1.82.02 | ||
| Siemens | N/A | SCALANCE X-200IRT | ||
| Siemens | N/A | SCALANCE X-200 versions antérieures à V5.2.4 | ||
| Siemens | N/A | SCALANCE X-200RNA versions antérieures à V3.2.6 | ||
| Siemens | N/A | SIMATIC Ident MV440 | ||
| Siemens | N/A | SCALANCE X-300 | ||
| Siemens | N/A | Siveillance VMS 2018 R2 versions antérieures à V12.2a | ||
| Siemens | N/A | Siveillance VMS 2018 R1 versions antérieures à V12.1a | ||
| Siemens | N/A | Siveillance VMS 2019 R1 versions antérieures à V13.1a | ||
| Siemens | N/A | Siveillance VMS 2017 R2 versions antérieures à V11.2a | ||
| Siemens | N/A | SCALANCE X-414-3E | ||
| Siemens | N/A | Siveillance VMS 2018 R3 versions antérieures à V12.3a |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC Ident MV420",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIEMENS LOGO!8 versions ant\u00e9rieures \u00e0 V1.82.02",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-200IRT",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-200 versions ant\u00e9rieures \u00e0 V5.2.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-200RNA versions ant\u00e9rieures \u00e0 V3.2.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Ident MV440",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-300",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance VMS 2018 R2 versions ant\u00e9rieures \u00e0 V12.2a",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance VMS 2018 R1 versions ant\u00e9rieures \u00e0 V12.1a",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance VMS 2019 R1 versions ant\u00e9rieures \u00e0 V13.1a",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance VMS 2017 R2 versions ant\u00e9rieures \u00e0 V11.2a",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-414-3E",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance VMS 2018 R3 versions ant\u00e9rieures \u00e0 V12.3a",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2019-6584",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6584"
},
{
"name": "CVE-2019-6567",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6567"
},
{
"name": "CVE-2019-6580",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6580"
},
{
"name": "CVE-2018-4833",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-4833"
},
{
"name": "CVE-2019-10926",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10926"
},
{
"name": "CVE-2019-6571",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6571"
},
{
"name": "CVE-2019-10925",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10925"
},
{
"name": "CVE-2019-6581",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6581"
},
{
"name": "CVE-2019-6582",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6582"
}
],
"initial_release_date": "2019-06-11T00:00:00",
"last_revision_date": "2019-06-11T00:00:00",
"links": [],
"reference": "CERTFR-2019-AVI-256",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-06-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-774850 du 11 juin 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-774850.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-816980 du 11 juin 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-646841 du 11 juin 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-181018 du 11 juin 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-181018.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-212009 du 11 juin 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf"
}
]
}
var-201906-1032
Vulnerability from variot
A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. SIMATIC Ident MV420 family and MV440 family Contains vulnerabilities related to authorization, permissions, and access control.Tampering with information and disrupting service operations (DoS) There is a possibility of being put into a state. The Siemens SIMATIC Ident MV 420 and the Siemens SIMATIC Ident MV 440 are both a code reading system from Siemens AG, Germany. Permissions and access control issues vulnerabilities exist in SiemensSIMATICIdentMV420 and SiemensSIMATICIdentMV440, which can be exploited by attackers to increase privileges. Siemens SIMATIC Ident MV420 and MV440 Families are prone to multiple security vulnerabilities
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201906-1032",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic mv420",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic mv440",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic ident mv420 family",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic ident mv440 family",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic ident mv440",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic ident mv420",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic ident mv440",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic ident mv420",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic mv420",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic mv440",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "76ec1ef8-02cf-4201-b562-6337ce2affb0"
},
{
"db": "CNVD",
"id": "CNVD-2019-21108"
},
{
"db": "BID",
"id": "108725"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005573"
},
{
"db": "NVD",
"id": "CVE-2019-10925"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:siemens:simatic_mv420_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:siemens:simatic_mv440_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-005573"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The vendor reported these issues.,Siemens PSIRT reported these vulnerabilities to NCCIC.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201906-523"
}
],
"trust": 0.6
},
"cve": "CVE-2019-10925",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CVE-2019-10925",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CNVD-2019-21108",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "76ec1ef8-02cf-4201-b562-6337ce2affb0",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "VHN-142520",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:N/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "LOW",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2019-10925",
"impactScore": 4.2,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "Low",
"baseScore": 7.1,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2019-10925",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-10925",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2019-10925",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2019-21108",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201906-523",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "76ec1ef8-02cf-4201-b562-6337ce2affb0",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-142520",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "76ec1ef8-02cf-4201-b562-6337ce2affb0"
},
{
"db": "CNVD",
"id": "CNVD-2019-21108"
},
{
"db": "VULHUB",
"id": "VHN-142520"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005573"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-523"
},
{
"db": "NVD",
"id": "CVE-2019-10925"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. SIMATIC Ident MV420 family and MV440 family Contains vulnerabilities related to authorization, permissions, and access control.Tampering with information and disrupting service operations (DoS) There is a possibility of being put into a state. The Siemens SIMATIC Ident MV 420 and the Siemens SIMATIC Ident MV 440 are both a code reading system from Siemens AG, Germany. Permissions and access control issues vulnerabilities exist in SiemensSIMATICIdentMV420 and SiemensSIMATICIdentMV440, which can be exploited by attackers to increase privileges. Siemens SIMATIC Ident MV420 and MV440 Families are prone to multiple security vulnerabilities",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-10925"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005573"
},
{
"db": "CNVD",
"id": "CNVD-2019-21108"
},
{
"db": "BID",
"id": "108725"
},
{
"db": "IVD",
"id": "76ec1ef8-02cf-4201-b562-6337ce2affb0"
},
{
"db": "VULHUB",
"id": "VHN-142520"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-10925",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-19-162-02",
"trust": 3.4
},
{
"db": "SIEMENS",
"id": "SSA-816980",
"trust": 2.0
},
{
"db": "BID",
"id": "108725",
"trust": 2.0
},
{
"db": "CNNVD",
"id": "CNNVD-201906-523",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2019-21108",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005573",
"trust": 0.8
},
{
"db": "IVD",
"id": "76EC1EF8-02CF-4201-B562-6337CE2AFFB0",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-142520",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "76ec1ef8-02cf-4201-b562-6337ce2affb0"
},
{
"db": "CNVD",
"id": "CNVD-2019-21108"
},
{
"db": "VULHUB",
"id": "VHN-142520"
},
{
"db": "BID",
"id": "108725"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005573"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-523"
},
{
"db": "NVD",
"id": "CVE-2019-10925"
}
]
},
"id": "VAR-201906-1032",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "76ec1ef8-02cf-4201-b562-6337ce2affb0"
},
{
"db": "CNVD",
"id": "CNVD-2019-21108"
},
{
"db": "VULHUB",
"id": "VHN-142520"
}
],
"trust": 1.5666666999999999
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "76ec1ef8-02cf-4201-b562-6337ce2affb0"
},
{
"db": "CNVD",
"id": "CNVD-2019-21108"
}
]
},
"last_update_date": "2024-11-23T22:41:28.891000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-816980",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-005573"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-284",
"trust": 1.0
},
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "CWE-264",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-142520"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005573"
},
{
"db": "NVD",
"id": "CVE-2019-10925"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.4,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-19-162-02"
},
{
"trust": 2.3,
"url": "http://www.securityfocus.com/bid/108725"
},
{
"trust": 2.0,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"trust": 0.9,
"url": "http://www.siemens.com/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10925"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-10925"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-162-02"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/simatic-ident-information-disclosure-via-web-session-29519"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-21108"
},
{
"db": "VULHUB",
"id": "VHN-142520"
},
{
"db": "BID",
"id": "108725"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005573"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-523"
},
{
"db": "NVD",
"id": "CVE-2019-10925"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "76ec1ef8-02cf-4201-b562-6337ce2affb0"
},
{
"db": "CNVD",
"id": "CNVD-2019-21108"
},
{
"db": "VULHUB",
"id": "VHN-142520"
},
{
"db": "BID",
"id": "108725"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005573"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-523"
},
{
"db": "NVD",
"id": "CVE-2019-10925"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-04T00:00:00",
"db": "IVD",
"id": "76ec1ef8-02cf-4201-b562-6337ce2affb0"
},
{
"date": "2019-07-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-21108"
},
{
"date": "2019-06-12T00:00:00",
"db": "VULHUB",
"id": "VHN-142520"
},
{
"date": "2019-06-11T00:00:00",
"db": "BID",
"id": "108725"
},
{
"date": "2019-06-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-005573"
},
{
"date": "2019-06-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201906-523"
},
{
"date": "2019-06-12T14:29:04.477000",
"db": "NVD",
"id": "CVE-2019-10925"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-21108"
},
{
"date": "2020-10-02T00:00:00",
"db": "VULHUB",
"id": "VHN-142520"
},
{
"date": "2019-06-11T00:00:00",
"db": "BID",
"id": "108725"
},
{
"date": "2019-06-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-005573"
},
{
"date": "2021-08-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201906-523"
},
{
"date": "2024-11-21T04:20:09.977000",
"db": "NVD",
"id": "CVE-2019-10925"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201906-523"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SIMATIC Ident MV420 family and MV440 family Vulnerabilities related to authorization, permissions, and access control",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-005573"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "access control error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201906-523"
}
],
"trust": 0.6
}
}
gsd-2019-10925
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2019-10925",
"description": "A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"id": "GSD-2019-10925"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2019-10925"
],
"details": "A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"id": "GSD-2019-10925",
"modified": "2023-12-13T01:23:57.248629Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10925",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC MV400 family",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c V7.0.6"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "108725",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108725"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_mv420_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_mv420:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_mv440_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_mv440:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10925"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf",
"refsource": "MISC",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02"
},
{
"name": "108725",
"refsource": "BID",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/108725"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 4.2
}
},
"lastModifiedDate": "2021-03-15T18:15Z",
"publishedDate": "2019-06-12T14:29Z"
}
}
}
cnvd-2019-21108
Vulnerability from cnvd
厂商尚未提供漏洞修复方案,请关注厂商主页更新: https://www.siemens.com/
| Name | ['Siemens SIMATIC Ident MV440', 'Siemens SIMATIC Ident MV420'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2019-10925"
}
},
"description": "Siemens SIMATIC Ident MV420\u548cSiemens SIMATIC Ident MV440\u90fd\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u5957\u4ee3\u7801\u8bfb\u53d6\u7cfb\u7edf\u3002\n\nSiemens SIMATIC Ident MV420\u548cSiemens SIMATIC Ident MV440\u4e2d\u5b58\u5728\u6743\u9650\u8bb8\u53ef\u548c\u8bbf\u95ee\u63a7\u5236\u95ee\u9898\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u63d0\u5347\u6743\u9650\u3002",
"discovererName": "Siemens",
"formalWay": "\u5382\u5546\u5c1a\u672a\u63d0\u4f9b\u6f0f\u6d1e\u4fee\u590d\u65b9\u6848\uff0c\u8bf7\u5173\u6ce8\u5382\u5546\u4e3b\u9875\u66f4\u65b0\uff1a\r\nhttps://www.siemens.com/",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2019-21108",
"openTime": "2019-07-04",
"products": {
"product": [
"Siemens SIMATIC Ident MV440",
"Siemens SIMATIC Ident MV420"
]
},
"referenceLink": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02",
"serverity": "\u4e2d",
"submitTime": "2019-06-12",
"title": "Siemens SIMATIC Ident MV420\u548cSiemens SIMATIC Ident MV440\u6743\u9650\u8bb8\u53ef\u548c\u8bbf\u95ee\u63a7\u5236\u95ee\u9898\u6f0f\u6d1e"
}
ghsa-978q-hc83-rf9p
Vulnerability from github
A vulnerability has been identified in SIMATIC Ident MV420 family (All versions), SIMATIC Ident MV440 family (All versions). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
{
"affected": [],
"aliases": [
"CVE-2019-10925"
],
"database_specific": {
"cwe_ids": [
"CWE-284"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2019-06-12T14:29:00Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in SIMATIC Ident MV420 family (All versions), SIMATIC Ident MV440 family (All versions). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device. Valid user credentials, but no user interaction are required. Successful exploitation compromises integrity and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.",
"id": "GHSA-978q-hc83-rf9p",
"modified": "2022-05-24T16:47:55Z",
"published": "2022-05-24T16:47:55Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-10925"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"type": "WEB",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02"
},
{
"type": "WEB",
"url": "http://www.securityfocus.com/bid/108725"
}
],
"schema_version": "1.4.0",
"severity": []
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.