CVE-2018-19944
Vulnerability from cvelistv5
Published
2020-12-31 16:33
Modified
2024-09-17 02:11
Severity ?
EPSS score ?
Summary
Cleartext Transmission of Sensitive Information in SNMP
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | QNAP Systems Inc. | QTS |
Version: unspecified < 4.4.3.1354 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:51:17.673Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "platforms": [ "build 20200702" ], "product": "QTS", "vendor": "QNAP Systems Inc.", "versions": [ { "lessThan": "4.4.3.1354", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Independent Security Evaluators" } ], "datePublic": "2020-12-30T00:00:00", "descriptions": [ { "lang": "en", "value": "A cleartext transmission of sensitive information vulnerability has been reported to affect certain QTS devices. If exploited, this vulnerability allows a remote attacker to gain access to sensitive information. QNAP have already fixed this vulnerability in the following versions: QTS 4.4.3.1354 build 20200702 (and later)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-311", "description": "CWE-311 Missing Encryption of Sensitive Data", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319 Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-31T16:33:27", "orgId": "2fd009eb-170a-4625-932b-17a53af1051f", "shortName": "qnap" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22" } ], "solutions": [ { "lang": "en", "value": "QNAP have already fixed this vulnerability in the following versions:\nQTS 4.4.3.1354 build 20200702 (and later)" } ], "source": { "advisory": "QSA-20-22", "discovery": "EXTERNAL" }, "title": "Cleartext Transmission of Sensitive Information in SNMP", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "security@qnap.com", "DATE_PUBLIC": "2020-12-30T02:55:00.000Z", "ID": "CVE-2018-19944", "STATE": "PUBLIC", "TITLE": "Cleartext Transmission of Sensitive Information in SNMP" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "QTS", "version": { "version_data": [ { "platform": "build 20200702", "version_affected": "\u003c", "version_value": "4.4.3.1354" } ] } } ] }, "vendor_name": "QNAP Systems Inc." } ] } }, "credit": [ { "lang": "eng", "value": "Independent Security Evaluators" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A cleartext transmission of sensitive information vulnerability has been reported to affect certain QTS devices. If exploited, this vulnerability allows a remote attacker to gain access to sensitive information. QNAP have already fixed this vulnerability in the following versions: QTS 4.4.3.1354 build 20200702 (and later)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-311 Missing Encryption of Sensitive Data" } ] }, { "description": [ { "lang": "eng", "value": "CWE-319 Cleartext Transmission of Sensitive Information" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22", "refsource": "MISC", "url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22" } ] }, "solution": [ { "lang": "en", "value": "QNAP have already fixed this vulnerability in the following versions:\nQTS 4.4.3.1354 build 20200702 (and later)" } ], "source": { "advisory": "QSA-20-22", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "2fd009eb-170a-4625-932b-17a53af1051f", "assignerShortName": "qnap", "cveId": "CVE-2018-19944", "datePublished": "2020-12-31T16:33:27.820049Z", "dateReserved": "2018-12-07T00:00:00", "dateUpdated": "2024-09-17T02:11:00.534Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-19944\",\"sourceIdentifier\":\"security@qnapsecurity.com.tw\",\"published\":\"2020-12-31T17:15:12.430\",\"lastModified\":\"2024-11-21T03:58:51.597\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A cleartext transmission of sensitive information vulnerability has been reported to affect certain QTS devices. If exploited, this vulnerability allows a remote attacker to gain access to sensitive information. QNAP have already fixed this vulnerability in the following versions: QTS 4.4.3.1354 build 20200702 (and later)\"},{\"lang\":\"es\",\"value\":\"Se ha reportado una vulnerabilidad de transmisi\u00f3n de texto sin cifrar de informaci\u00f3n confidencial que afecta a determinados dispositivos QTS.\u0026#xa0;Si se explota, esta vulnerabilidad permite a un atacante remoto obtener acceso a informaci\u00f3n confidencial.\u0026#xa0;QNAP ya ha corregido esta vulnerabilidad en las siguientes versiones: QTS versi\u00f3n 4.4.3.1354 build 20200702 (y posteriores)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"security@qnapsecurity.com.tw\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-311\"},{\"lang\":\"en\",\"value\":\"CWE-319\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:qnap:qts:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.4.3.1354\",\"matchCriteriaId\":\"5C993531-A910-4F15-ABD3-31261D560C76\"}]}]}],\"references\":[{\"url\":\"https://www.qnap.com/zh-tw/security-advisory/qsa-20-22\",\"source\":\"security@qnapsecurity.com.tw\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.qnap.com/zh-tw/security-advisory/qsa-20-22\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.