CVE-2015-5374 (GCVE-0-2015-5374)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T06:41:09.550Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" }, { "name": "44103", "tags": [ "exploit", "x_refsource_EXPLOIT-DB", "x_transferred" ], "url": "https://www.exploit-db.com/exploits/44103/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "name": "75948", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/75948" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2017-07-04T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-03-22T16:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" }, { "name": "44103", "tags": [ "exploit", "x_refsource_EXPLOIT-DB" ], "url": "https://www.exploit-db.com/exploits/44103/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "name": "75948", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/75948" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "DATE_PUBLIC": "2017-07-04T00:00:00", "ID": "CVE-2015-5374", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf", "refsource": "CONFIRM", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" }, { "name": "44103", "refsource": "EXPLOIT-DB", "url": "https://www.exploit-db.com/exploits/44103/" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "name": "75948", "refsource": "BID", "url": "http://www.securityfocus.com/bid/75948" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2015-5374", "datePublished": "2015-07-18T10:00:00Z", "dateReserved": "2015-07-06T00:00:00", "dateUpdated": "2024-09-17T02:15:53.925Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2015-5374\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2015-07-18T10:59:04.117\",\"lastModified\":\"2025-04-12T10:46:40.837\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02. Los paquetes especialmente manipulados enviados al puerto 50000/UDP podr\u00edan provocar una denegaci\u00f3n de servicio (DoS) en el dispositivo afectado. Podr\u00eda ser necesario el reinicio manual para recuperar el servicio del dispositivo.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:C\",\"baseScore\":7.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-19\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:siprotec_firmware:4.24:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"54A8F628-D8DD-48A1-BC79-802E7573CDA0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_4:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4F0799D8-BFAC-4DC7-B465-9C757923DD94\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_compact:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"24E3447F-6F7D-40B0-9D48-68C07FFA133B\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/75948\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.exploit-db.com/exploits/44103/\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.securityfocus.com/bid/75948\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.exploit-db.com/exploits/44103/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
icsa-15-202-01
Vulnerability from csaf_cisa
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-15-202-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2015/icsa-15-202-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-15-202-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-202-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" } ], "title": "Siemens SIPROTEC Denial-of-Service Vulnerability", "tracking": { "current_release_date": "2025-06-25T22:54:08.041405Z", "generator": { "date": "2025-06-25T22:54:08.041295Z", "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-15-202-01", "initial_release_date": "2015-04-23T06:00:00.000000Z", "revision_history": [ { "date": "2015-04-23T06:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Initial Publication" }, { "date": "2025-06-25T22:54:08.041405Z", "legacy_version": "CSAF Conversion", "number": "2", "summary": "Advisory converted into a CSAF" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Siemens SIPROTEC 4 and SIPROTEC Compact product families: vers:all/*", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIPROTEC 4 and SIPROTEC Compact product families" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=V4.24", "product": { "name": "Siemens EN100 Ethernet module: \u003c=V4.24", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "EN100 Ethernet module" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2015-5374", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "remediations": [ { "category": "mitigation", "details": "Siemens has provided firmware update V4.25 for the EN100 module to fix the vulnerability.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "The firmware update for SIPROTEC 4 can be obtained here: (http://www.siemens.com/downloads/siprotec-4)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/downloads/siprotec-4" }, { "category": "mitigation", "details": "The firmware update for SIPROTEC Compact can be obtained here: (http://www.siemens.com/downloads/siprotec-compact)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/downloads/siprotec-compact" }, { "category": "mitigation", "details": "For more information on this vulnerability and more detailed mitigation instructions, please see Siemens Security Advisory SSA-732541 at the following location: (http://www.siemens.com/cert/advisories)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/cert/advisories" } ], "scores": [ { "cvss_v2": { "baseScore": 7.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }
ICSA-17-187-03F
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reported this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s TXT advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "As a general security measure Siemens strongly recommends to protectnetwork access with appropriate mechanisms (e.g. firewalls,segmentation, VPN). It is advised to configure the environment accordingto our operational guidelines in order to run the devices in a protectedIT environment.", "title": "General Recommendations" }, { "category": "general", "text": "Recommended security guidelines to Secure Substations can be found at:https://www.siemens.com/gridsecurity", "title": "General Recommendations" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions containedin Siemens\u0027 underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter \"License Terms\"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website(https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-323211: Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact Devices", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-323211.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-17-187-03F JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/refs/heads/develop/csaf_files/OT/white/2017/icsa-17-187-03F.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-17-187-03F - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-03F" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "ICSA-17-187-03F Siemens SIPROTEC 4 and SIPROTEC Compact (Update F)", "tracking": { "current_release_date": "2018-06-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-187-03F", "initial_release_date": "2017-07-04T00:00:00.000000Z", "revision_history": [ { "date": "2017-07-04T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2017-07-18T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Added update for DNP3 TCP" }, { "date": "2017-07-25T00:00:00.000000Z", "legacy_version": "1.2", "number": "3", "summary": "Added update for IEC 104" }, { "date": "2017-09-07T00:00:00.000000Z", "legacy_version": "1.3", "number": "4", "summary": "Added update for Modbus TCP" }, { "date": "2017-10-09T00:00:00.000000Z", "legacy_version": "1.4", "number": "5", "summary": "Corrected \"Affected Products\" and added update for SIPROTEC 7SJ686" }, { "date": "2017-11-30T00:00:00.000000Z", "legacy_version": "1.5", "number": "6", "summary": "Added update for 7SD686" }, { "date": "2017-12-22T00:00:00.000000Z", "legacy_version": "1.6", "number": "7", "summary": "Added update for 7UT686" }, { "date": "2018-03-15T00:00:00.000000Z", "legacy_version": "1.7000000000000002", "number": "8", "summary": "Added update for 7SJ66" }, { "date": "2018-06-12T00:00:00.000000Z", "legacy_version": "1.8", "number": "9", "summary": "Clarified update for 7SJ686" } ], "status": "final", "version": "9" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1.04.01", "product": { "name": "Firmware variant PROFINET IO for EN100 Ethernet module", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Firmware variant PROFINET IO for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV1.11.00", "product": { "name": "Firmware variant Modbus TCP for EN100 Ethernet module", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Firmware variant Modbus TCP for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV1.03", "product": { "name": "Firmware variant DNP3 TCP for EN100 Ethernet module", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Firmware variant DNP3 TCP for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV1.21", "product": { "name": "Firmware variant IEC 104 for EN100 Ethernet module", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Firmware variant IEC 104 for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "\u003c1.02.02", "product": { "name": "EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.83", "product": { "name": "SIPROTEC 7SJ686", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "SIPROTEC 7SJ686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.87", "product": { "name": "SIPROTEC 7SJ686", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "SIPROTEC 7SJ686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.01", "product": { "name": "SIPROTEC 7UT686", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "SIPROTEC 7UT686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.02", "product": { "name": "SIPROTEC 7UT686", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "SIPROTEC 7UT686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.03", "product": { "name": "SIPROTEC 7SD686", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "SIPROTEC 7SD686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.05", "product": { "name": "SIPROTEC 7SD686", "product_id": "CSAFPID-00011" } } ], "category": "product_name", "name": "SIPROTEC 7SD686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.20", "product": { "name": "SIPROTEC 7SJ66", "product_id": "CSAFPID-00012" } } ], "category": "product_name", "name": "SIPROTEC 7SJ66" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.30", "product": { "name": "SIPROTEC 7SJ66", "product_id": "CSAFPID-00013" } } ], "category": "product_name", "name": "SIPROTEC 7SJ66" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2015-5374", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2015-5374" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:H/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:H/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-4784", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4784" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Install V 4.83 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51", "product_ids": [ "CSAFPID-0006" ] }, { "category": "mitigation", "details": "Install V 4.01 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68", "product_ids": [ "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Install V 4.03 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64", "product_ids": [ "CSAFPID-00010" ] }, { "category": "vendor_fix", "details": "Install V 4.20 - Download: https://support.industry.siemens.com/cs/gb/en/view/109743555", "product_ids": [ "CSAFPID-00012" ], "url": "https://support.industry.siemens.com/cs/gb/en/view/109743555" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-4785", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (port 80/tcp) of the affected devices could allow remoteattackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4785" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7112", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7112" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7113", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7113" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7114", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7114" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Install V 4.87 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51", "product_ids": [ "CSAFPID-0007" ] }, { "category": "mitigation", "details": "Install V4.02 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68", "product_ids": [ "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Install V4.05 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64", "product_ids": [ "CSAFPID-00011" ] }, { "category": "vendor_fix", "details": "Install V 4.30 - Download: https://support.industry.siemens.com/cs/us/en/view/109743555", "product_ids": [ "CSAFPID-00013" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] } ] }
icsa-17-187-03f
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reported this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s TXT advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "As a general security measure Siemens strongly recommends to protectnetwork access with appropriate mechanisms (e.g. firewalls,segmentation, VPN). It is advised to configure the environment accordingto our operational guidelines in order to run the devices in a protectedIT environment.", "title": "General Recommendations" }, { "category": "general", "text": "Recommended security guidelines to Secure Substations can be found at:https://www.siemens.com/gridsecurity", "title": "General Recommendations" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions containedin Siemens\u0027 underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter \"License Terms\"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website(https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-323211: Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact Devices", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-323211.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-17-187-03F JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/refs/heads/develop/csaf_files/OT/white/2017/icsa-17-187-03F.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-17-187-03F - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-03F" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "ICSA-17-187-03F Siemens SIPROTEC 4 and SIPROTEC Compact (Update F)", "tracking": { "current_release_date": "2018-06-12T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-187-03F", "initial_release_date": "2017-07-04T00:00:00.000000Z", "revision_history": [ { "date": "2017-07-04T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2017-07-18T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Added update for DNP3 TCP" }, { "date": "2017-07-25T00:00:00.000000Z", "legacy_version": "1.2", "number": "3", "summary": "Added update for IEC 104" }, { "date": "2017-09-07T00:00:00.000000Z", "legacy_version": "1.3", "number": "4", "summary": "Added update for Modbus TCP" }, { "date": "2017-10-09T00:00:00.000000Z", "legacy_version": "1.4", "number": "5", "summary": "Corrected \"Affected Products\" and added update for SIPROTEC 7SJ686" }, { "date": "2017-11-30T00:00:00.000000Z", "legacy_version": "1.5", "number": "6", "summary": "Added update for 7SD686" }, { "date": "2017-12-22T00:00:00.000000Z", "legacy_version": "1.6", "number": "7", "summary": "Added update for 7UT686" }, { "date": "2018-03-15T00:00:00.000000Z", "legacy_version": "1.7000000000000002", "number": "8", "summary": "Added update for 7SJ66" }, { "date": "2018-06-12T00:00:00.000000Z", "legacy_version": "1.8", "number": "9", "summary": "Clarified update for 7SJ686" } ], "status": "final", "version": "9" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV1.04.01", "product": { "name": "Firmware variant PROFINET IO for EN100 Ethernet module", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Firmware variant PROFINET IO for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV1.11.00", "product": { "name": "Firmware variant Modbus TCP for EN100 Ethernet module", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Firmware variant Modbus TCP for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV1.03", "product": { "name": "Firmware variant DNP3 TCP for EN100 Ethernet module", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Firmware variant DNP3 TCP for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV1.21", "product": { "name": "Firmware variant IEC 104 for EN100 Ethernet module", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Firmware variant IEC 104 for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "\u003c1.02.02", "product": { "name": "EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.83", "product": { "name": "SIPROTEC 7SJ686", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "SIPROTEC 7SJ686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.87", "product": { "name": "SIPROTEC 7SJ686", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "SIPROTEC 7SJ686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.01", "product": { "name": "SIPROTEC 7UT686", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "SIPROTEC 7UT686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.02", "product": { "name": "SIPROTEC 7UT686", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "SIPROTEC 7UT686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.03", "product": { "name": "SIPROTEC 7SD686", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "SIPROTEC 7SD686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.05", "product": { "name": "SIPROTEC 7SD686", "product_id": "CSAFPID-00011" } } ], "category": "product_name", "name": "SIPROTEC 7SD686" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.20", "product": { "name": "SIPROTEC 7SJ66", "product_id": "CSAFPID-00012" } } ], "category": "product_name", "name": "SIPROTEC 7SJ66" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV_4.30", "product": { "name": "SIPROTEC 7SJ66", "product_id": "CSAFPID-00013" } } ], "category": "product_name", "name": "SIPROTEC 7SJ66" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2015-5374", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2015-5374" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:H/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:H/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-4784", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4784" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Install V 4.83 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51", "product_ids": [ "CSAFPID-0006" ] }, { "category": "mitigation", "details": "Install V 4.01 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68", "product_ids": [ "CSAFPID-0008" ] }, { "category": "mitigation", "details": "Install V 4.03 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64", "product_ids": [ "CSAFPID-00010" ] }, { "category": "vendor_fix", "details": "Install V 4.20 - Download: https://support.industry.siemens.com/cs/gb/en/view/109743555", "product_ids": [ "CSAFPID-00012" ], "url": "https://support.industry.siemens.com/cs/gb/en/view/109743555" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-4785", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (port 80/tcp) of the affected devices could allow remoteattackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4785" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7112", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7112" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7113", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7113" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7114", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7114" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "Install V1.02.02 - Download: Please contact the Siemens hotline at support.energy@siemens.com", "product_ids": [ "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Install V 4.87 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51", "product_ids": [ "CSAFPID-0007" ] }, { "category": "mitigation", "details": "Install V4.02 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68", "product_ids": [ "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Install V4.05 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64", "product_ids": [ "CSAFPID-00011" ] }, { "category": "vendor_fix", "details": "Install V 4.30 - Download: https://support.industry.siemens.com/cs/us/en/view/109743555", "product_ids": [ "CSAFPID-00013" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Apply secure substation concept and Defense-in-Depth (see https://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ], "url": "https://www.siemens.com/gridsecurity" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk: Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] } ] }
var-201507-0039
Vulnerability from variot
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device. Siemens SIPROTEC 4 and SIPROTEC Compact Device EN100 Module firmware has a service disruption (DoS) There are vulnerabilities that are put into a state. Supplementary information : CWE Vulnerability type by CWE-19: Data Handling ( Data processing ) Has been identified. http://cwe.mitre.org/data/definitions/19.htmlBy a third party UDP port 50000 Denial of service via the above crafted packets (DoS) There is a possibility of being put into a state. The SIPROTEC 4 and SIPROTEC devices offer a wide range of integrated protection, control, measurement and power substation automation functions; the EN100 module is used for IEC 61850 communication. The EN100 module for multiple Siemens SIPROTEC products are prone to a denial-of-service vulnerability. Remote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users. Both Siemens SIPROTEC 4 and SIPROTEC Compact are products of Siemens, Germany. Siemens SIPROTEC 4 is a series of multifunctional relays with a friendly man-machine interface. SIPROTEC Compact is a microcomputer protection device. EN100 is one of the multi-format encoder modules
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201507-0039", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "siprotec", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "4.24" }, { "model": "siprotec 4", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "siprotec compact", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "siprotec", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "4.25" }, { "model": "siprotec", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v4.24" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "siprotec", "version": "4.24" }, { "model": "siprotec compact", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7ut686", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7sj686", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7sj66", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7sd686", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "40" }, { "model": "profinet io", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "modbus tcp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "iec", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1040" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.9" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.5" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.4" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.3" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.24" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.23" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.22" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.21" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.20" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.2" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.19" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.18" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.17" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.16" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.15" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.14" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.13" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.12" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.11" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.10" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.1" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.0" }, { "model": "dnp3 tcp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "profinet io", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1.4.1" }, { "model": "en100", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.25" } ], "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "BID", "id": "75948" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/h:siemens:siprotec_4", "vulnerable": true }, { "cpe22Uri": "cpe:/h:siemens:siprotec_compact", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:siprotec_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2015-003890" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "M. Can Kurnaz", "sources": [ { "db": "CNNVD", "id": "CNNVD-201507-644" } ], "trust": 0.6 }, "cve": "CVE-2015-5374", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2015-5374", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2015-04733", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "78fdecc2-a9af-4a66-b218-01a620b751d5", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "820a6b4c-2351-11e6-abef-000c29c66e3d", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-83335", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2015-5374", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2015-5374", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2015-04733", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201507-644", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5", "trust": 0.2, "value": "HIGH" }, { "author": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-83335", "trust": 0.1, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2015-5374", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device. Siemens SIPROTEC 4 and SIPROTEC Compact Device EN100 Module firmware has a service disruption (DoS) There are vulnerabilities that are put into a state. Supplementary information : CWE Vulnerability type by CWE-19: Data Handling ( Data processing ) Has been identified. http://cwe.mitre.org/data/definitions/19.htmlBy a third party UDP port 50000 Denial of service via the above crafted packets (DoS) There is a possibility of being put into a state. The SIPROTEC 4 and SIPROTEC devices offer a wide range of integrated protection, control, measurement and power substation automation functions; the EN100 module is used for IEC 61850 communication. The EN100 module for multiple Siemens SIPROTEC products are prone to a denial-of-service vulnerability. \nRemote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users. Both Siemens SIPROTEC 4 and SIPROTEC Compact are products of Siemens, Germany. Siemens SIPROTEC 4 is a series of multifunctional relays with a friendly man-machine interface. SIPROTEC Compact is a microcomputer protection device. EN100 is one of the multi-format encoder modules", "sources": [ { "db": "NVD", "id": "CVE-2015-5374" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "BID", "id": "75948" }, { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" } ], "trust": 2.97 }, "exploit_availability": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "reference": "https://www.scap.org.cn/vuln/vhn-83335", "trust": 0.1, "type": "unknown" }, { "reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=44103", "trust": 0.1, "type": "exploit" } ], "sources": [ { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" } ] }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2015-5374", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-17-187-03", "trust": 2.3 }, { "db": "ICS CERT", "id": "ICSA-15-202-01", "trust": 2.3 }, { "db": "SIEMENS", "id": "SSA-732541", "trust": 2.1 }, { "db": "BID", "id": "75948", "trust": 2.1 }, { "db": "EXPLOIT-DB", "id": "44103", "trust": 1.2 }, { "db": "SIEMENS", "id": "SSA-323211", "trust": 1.2 }, { "db": "CNNVD", "id": "CNNVD-201507-644", "trust": 1.1 }, { "db": "CNVD", "id": "CNVD-2015-04733", "trust": 1.0 }, { "db": "JVNDB", "id": "JVNDB-2015-003890", "trust": 0.8 }, { "db": "CXSECURITY", "id": "WLB-2018020218", "trust": 0.6 }, { "db": "IVD", "id": "78FDECC2-A9AF-4A66-B218-01A620B751D5", "trust": 0.2 }, { "db": "IVD", "id": "820A6B4C-2351-11E6-ABEF-000C29C66E3D", "trust": 0.2 }, { "db": "PACKETSTORM", "id": "146427", "trust": 0.1 }, { "db": "SEEBUG", "id": "SSVID-89506", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-83335", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2015-5374", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" }, { "db": "BID", "id": "75948" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "id": "VAR-201507-0039", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULHUB", "id": "VHN-83335" } ], "trust": 1.6782828066666666 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.4 } ], "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" } ] }, "last_update_date": "2024-11-23T22:13:28.564000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-73254", "trust": 0.8, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" }, { "title": "SIPROTEC 4 denial of service vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/61054" }, { "title": "Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Fixes for module denial of service vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=160157" }, { "title": "The Register", "trust": 0.2, "url": "https://www.theregister.co.uk/2017/06/12/industroyer_malware/" }, { "title": "IDPS", "trust": 0.1, "url": "https://github.com/g4xyk00/IDPS " }, { "title": "CVE-2015-5374-DoS-PoC", "trust": 0.1, "url": "https://github.com/can/CVE-2015-5374-DoS-PoC " }, { "title": "", "trust": 0.1, "url": "https://github.com/khulnasoft-labs/awesome-security " }, { "title": "welivesecurity", "trust": 0.1, "url": "https://www.welivesecurity.com/2017/06/12/industroyer-biggest-threat-industrial-control-systems-since-stuxnet/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULMON", "id": "CVE-2015-5374" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-19", "trust": 1.1 }, { "problemtype": "CWE-Other", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-83335" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://ics-cert.us-cert.gov/advisories/icsa-15-202-01" }, { "trust": 2.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-187-03" }, { "trust": 2.1, "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" }, { "trust": 1.3, "url": "https://www.exploit-db.com/exploits/44103/" }, { "trust": 1.2, "url": "http://www.securityfocus.com/bid/75948" }, { "trust": 1.2, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-323211.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-5374" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-5374" }, { "trust": 0.6, "url": "https://cxsecurity.com/issue/wlb-2018020218" }, { "trust": 0.3, "url": "http://w3.siemens.com/smartgrid/global/en/products-systems-solutions/protection/siprotec4/pages/overview.aspx" }, { "trust": 0.3, "url": "http://w3.siemens.com/smartgrid/global/en/products-systems-solutions/protection/siprotec-compact/pages/overview.aspx" }, { "trust": 0.3, "url": "http://www.siemens.com/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/19.html" }, { "trust": 0.1, "url": "https://github.com/g4xyk00/idps" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "http://tools.cisco.com/security/center/viewalert.x?alertid=40100" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" }, { "db": "BID", "id": "75948" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" }, { "db": "VULHUB", "id": "VHN-83335" }, { "db": "VULMON", "id": "CVE-2015-5374" }, { "db": "BID", "id": "75948" }, { "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "db": "CNNVD", "id": "CNNVD-201507-644" }, { "db": "NVD", "id": "CVE-2015-5374" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2015-07-23T00:00:00", "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "date": "2015-07-23T00:00:00", "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "date": "2015-07-23T00:00:00", "db": "CNVD", "id": "CNVD-2015-04733" }, { "date": "2015-07-18T00:00:00", "db": "VULHUB", "id": "VHN-83335" }, { "date": "2015-07-18T00:00:00", "db": "VULMON", "id": "CVE-2015-5374" }, { "date": "2015-07-17T00:00:00", "db": "BID", "id": "75948" }, { "date": "2015-07-23T00:00:00", "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "date": "2015-07-20T00:00:00", "db": "CNNVD", "id": "CNNVD-201507-644" }, { "date": "2015-07-18T10:59:04.117000", "db": "NVD", "id": "CVE-2015-5374" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2015-07-25T00:00:00", "db": "CNVD", "id": "CNVD-2015-04733" }, { "date": "2018-03-23T00:00:00", "db": "VULHUB", "id": "VHN-83335" }, { "date": "2018-03-23T00:00:00", "db": "VULMON", "id": "CVE-2015-5374" }, { "date": "2017-07-11T12:06:00", "db": "BID", "id": "75948" }, { "date": "2017-09-11T00:00:00", "db": "JVNDB", "id": "JVNDB-2015-003890" }, { "date": "2021-08-18T00:00:00", "db": "CNNVD", "id": "CNNVD-201507-644" }, { "date": "2024-11-21T02:32:54.457000", "db": "NVD", "id": "CVE-2015-5374" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201507-644" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIPROTEC 4 Denial of service vulnerability", "sources": [ { "db": "IVD", "id": "78fdecc2-a9af-4a66-b218-01a620b751d5" }, { "db": "IVD", "id": "820a6b4c-2351-11e6-abef-000c29c66e3d" }, { "db": "CNVD", "id": "CNVD-2015-04733" } ], "trust": 1.0 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-201507-644" } ], "trust": 0.6 } }
gsd-2015-5374
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2015-5374", "description": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.", "id": "GSD-2015-5374", "references": [ "https://packetstormsecurity.com/files/cve/CVE-2015-5374" ] }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2015-5374" ], "details": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.", "id": "GSD-2015-5374", "modified": "2023-12-13T01:20:06.668750Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "DATE_PUBLIC": "2017-07-04T00:00:00", "ID": "CVE-2015-5374", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf", "refsource": "CONFIRM", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" }, { "name": "44103", "refsource": "EXPLOIT-DB", "url": "https://www.exploit-db.com/exploits/44103/" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "name": "75948", "refsource": "BID", "url": "http://www.securityfocus.com/bid/75948" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:siprotec_firmware:4.24:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:siprotec_4:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:siprotec_compact:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2015-5374" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-19" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf", "refsource": "CONFIRM", "tags": [ "Patch", "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" }, { "name": "75948", "refsource": "BID", "tags": [], "url": "http://www.securityfocus.com/bid/75948" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01", "refsource": "MISC", "tags": [], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01" }, { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf", "refsource": "CONFIRM", "tags": [], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03", "refsource": "MISC", "tags": [], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "name": "44103", "refsource": "EXPLOIT-DB", "tags": [], "url": "https://www.exploit-db.com/exploits/44103/" } ] } }, "impact": { "baseMetricV2": { "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false } }, "lastModifiedDate": "2018-03-23T01:29Z", "publishedDate": "2015-07-18T10:59Z" } } }
cnvd-2015-04733
Vulnerability from cnvd
Title: Siemens SIPROTEC 4拒绝服务漏洞
Description:
SIPROTEC 4和SIPROTEC设备提供范围广泛的集成保护、控制、测量和电力变电站自动化功能,;EN100模块用于实现IEC 61850通信。
SIPROTEC 4被披露存在拒绝服务漏洞,攻击者利用漏洞发送特制的数据包到端口50000 / udp可导致拒绝服务,需要手动重启恢复设备的服务。
Severity: 高
Patch Name: SIPROTEC 4拒绝服务漏洞的补丁
Patch Description:
SIPROTEC 4和SIPROTEC设备提供范围广泛的集成保护、控制、测量和电力变电站自动化功能,;EN100模块用于实现IEC 61850通信。 SIPROTEC 4被披露存在拒绝服务漏洞,攻击者利用漏洞发送特制的数据包到端口50000 / udp可导致拒绝服务,需要手动重启恢复设备的服务。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description:
厂商已提供固件更新V4.25 EN100模块修复漏洞:http://www.siemens.com/downloads/siprotec-4 http://www.siemens.com/downloads/siprotec-compact
Reference: http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf
Name | Siemens SIPROTEC <V4.24 |
---|
{ "bids": { "bid": { "bidNumber": "75948" } }, "cves": { "cve": { "cveNumber": "CVE-2015-5374" } }, "description": "SIPROTEC 4\u548cSIPROTEC\u8bbe\u5907\u63d0\u4f9b\u8303\u56f4\u5e7f\u6cdb\u7684\u96c6\u6210\u4fdd\u62a4\u3001\u63a7\u5236\u3001\u6d4b\u91cf\u548c\u7535\u529b\u53d8\u7535\u7ad9\u81ea\u52a8\u5316\u529f\u80fd\uff0c\uff1bEN100\u6a21\u5757\u7528\u4e8e\u5b9e\u73b0IEC 61850\u901a\u4fe1\u3002\r\n\r\nSIPROTEC 4\u88ab\u62ab\u9732\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u5229\u7528\u6f0f\u6d1e\u53d1\u9001\u7279\u5236\u7684\u6570\u636e\u5305\u5230\u7aef\u53e350000 / udp\u53ef\u5bfc\u81f4\u62d2\u7edd\u670d\u52a1\uff0c\u9700\u8981\u624b\u52a8\u91cd\u542f\u6062\u590d\u8bbe\u5907\u7684\u670d\u52a1\u3002", "discovererName": "Victor Nikitin from i-Grids LLC Russia", "formalWay": "\u5382\u5546\u5df2\u63d0\u4f9b\u56fa\u4ef6\u66f4\u65b0V4.25 EN100\u6a21\u5757\u4fee\u590d\u6f0f\u6d1e\uff1ahttp://www.siemens.com/downloads/siprotec-4\r\nhttp://www.siemens.com/downloads/siprotec-compact", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2015-04733", "openTime": "2015-07-23", "patchDescription": "SIPROTEC 4\u548cSIPROTEC\u8bbe\u5907\u63d0\u4f9b\u8303\u56f4\u5e7f\u6cdb\u7684\u96c6\u6210\u4fdd\u62a4\u3001\u63a7\u5236\u3001\u6d4b\u91cf\u548c\u7535\u529b\u53d8\u7535\u7ad9\u81ea\u52a8\u5316\u529f\u80fd\uff0c\uff1bEN100\u6a21\u5757\u7528\u4e8e\u5b9e\u73b0IEC 61850\u901a\u4fe1\u3002 \r\nSIPROTEC 4\u88ab\u62ab\u9732\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u5229\u7528\u6f0f\u6d1e\u53d1\u9001\u7279\u5236\u7684\u6570\u636e\u5305\u5230\u7aef\u53e350000 / udp\u53ef\u5bfc\u81f4\u62d2\u7edd\u670d\u52a1\uff0c\u9700\u8981\u624b\u52a8\u91cd\u542f\u6062\u590d\u8bbe\u5907\u7684\u670d\u52a1\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "SIPROTEC 4\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": "Siemens SIPROTEC \u003cV4.24" }, "referenceLink": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf", "serverity": "\u9ad8", "submitTime": "2015-07-20", "title": "Siemens SIPROTEC 4\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e" }
fkie_cve-2015-5374
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
siemens | siprotec_firmware | 4.24 | |
siemens | siprotec_4 | * | |
siemens | siprotec_compact | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:siprotec_firmware:4.24:*:*:*:*:*:*:*", "matchCriteriaId": "54A8F628-D8DD-48A1-BC79-802E7573CDA0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:siprotec_4:*:*:*:*:*:*:*:*", "matchCriteriaId": "4F0799D8-BFAC-4DC7-B465-9C757923DD94", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:siprotec_compact:*:*:*:*:*:*:*:*", "matchCriteriaId": "24E3447F-6F7D-40B0-9D48-68C07FFA133B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02. Los paquetes especialmente manipulados enviados al puerto 50000/UDP podr\u00edan provocar una denegaci\u00f3n de servicio (DoS) en el dispositivo afectado. Podr\u00eda ser necesario el reinicio manual para recuperar el servicio del dispositivo." } ], "id": "CVE-2015-5374", "lastModified": "2025-04-12T10:46:40.837", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2015-07-18T10:59:04.117", "references": [ { "source": "cve@mitre.org", "url": "http://www.securityfocus.com/bid/75948" }, { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" }, { "source": "cve@mitre.org", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01" }, { "source": "cve@mitre.org", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "source": "cve@mitre.org", "url": "https://www.exploit-db.com/exploits/44103/" }, { "source": "cve@mitre.org", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.securityfocus.com/bid/75948" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.exploit-db.com/exploits/44103/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-19" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
tid-404
Vulnerability from emb3d
Some devices will have operating modes that put the device in an inoperable state. Devices may also have network parsing or protocol vulnerabilities that can put the device in a deadlocked or otherwise unresponsive state. A threat actor may therefore be able to send a message to a device that causes it to enter one of these deadlocked or unresponsive states, rendering the device non-functional or leaving it in an otherwise degraded state. Additionally, if the device does not have a mechanism to reset or recover from this state, it may remain unavailable until it is reset or rebooted, which may require physical operator presence.
- CWE-833: Deadlock
tid-217
Vulnerability from emb3d
When firmware/software update process is initiated on a device, it may enter a different operational mode where it stops performing key functions, including networking, data collection, or control functions. Therefore, a threat actor could remotely initiate the firmware/software update to cause a denial of service on the device.
- CWE-400: Uncontrolled Resource Consumption
ghsa-26f6-7cv9-7mh6
Vulnerability from github
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.
{ "affected": [], "aliases": [ "CVE-2015-5374" ], "database_specific": { "cwe_ids": [], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2015-07-18T10:59:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.", "id": "GHSA-26f6-7cv9-7mh6", "modified": "2025-04-12T12:50:13Z", "published": "2022-05-14T03:35:57Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2015-5374" }, { "type": "WEB", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01" }, { "type": "WEB", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "type": "WEB", "url": "https://www.exploit-db.com/exploits/44103" }, { "type": "WEB", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/75948" }, { "type": "WEB", "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf" } ], "schema_version": "1.4.0", "severity": [] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.