Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2016-7113
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T01:50:47.436Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "92748", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/92748" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf" }, { "name": "99471", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/99471" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2017-07-04T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-03-22T17:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "name": "92748", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/92748" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf" }, { "name": "99471", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/99471" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "DATE_PUBLIC": "2017-07-04T00:00:00", "ID": "CVE-2016-7113", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "92748", "refsource": "BID", "url": "http://www.securityfocus.com/bid/92748" }, { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf", "refsource": "CONFIRM", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf" }, { "name": "99471", "refsource": "BID", "url": "http://www.securityfocus.com/bid/99471" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2016-7113", "datePublished": "2016-09-06T00:00:00Z", "dateReserved": "2016-08-30T00:00:00", "dateUpdated": "2024-09-16T16:19:06.371Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2016-7113\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2016-09-06T00:59:01.883\",\"lastModified\":\"2024-11-21T02:57:29.400\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02. El env\u00edo de paquetes especialmente manipulados al puerto 80/tcp podr\u00edan provocar que el dispositivo afectado entre en modo defect.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:C\",\"baseScore\":7.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.9,\"acInsufInfo\":true,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-399\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:en100_ethernet_module_firmware:4.28:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"862476A4-6C97-4E00-9EC1-5EEA8A27EE73\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:en100_ethernet_module:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DAC429FD-7148-4A68-AA81-8FBADA588F4E\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/92748\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.securityfocus.com/bid/99471\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.securityfocus.com/bid/92748\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.securityfocus.com/bid/99471\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
var-201609-0492
Vulnerability from variot
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode. Siemens SIPROTEC 4 and SIPROTEC Compact For devices EN100 Ethernet Module contains service disruption ( Transition to defect mode (defect-mode transition)) There are vulnerabilities that are put into a state.Skillfully crafted by a third party HTTP Service disruption via packets ( Transition to defect mode (defect-mode transition)) There is a possibility of being put into a state. SIPROTEC 4 and SIPROTEC Compact devices offer a wide range of centralized protection, control and automation functions for substations and other applications. Siemens SIPROTEC 4, SIPROTEC Compact, a denial of service vulnerability exists in versions prior to EN100 Ethernet 4.29. A remote attacker can cause a denial of service by constructing an HTTP packet. An attacker can exploit this issue to cause denial-of-service conditions. EN100 Ethernet Modules for Reyrolle is prone to the following security vulnerabilities: : 1. Multiple information-disclosure vulnerabilities 2. A denial-of-service vulnerability 3. Multiple authentication-bypass vulnerabilities An attacker may leverage these issues to disclose sensitive information, perform certain unauthorized actions actions, gain unauthorized access, or bypass certain security restrictions and cause a denial-of-service condition. Both Siemens SIPROTEC 4 and SIPROTEC Compact are products of Siemens, Germany. Siemens SIPROTEC 4 is a series of multifunctional relays with a friendly man-machine interface. SIPROTEC Compact is a microcomputer protection device
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201609-0492", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "en100 ethernet module", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "4.28" }, { "model": "en100 module", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "en100 module", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "4.29" }, { "model": "siprotec compact \u003cen100 ethernet", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "4.29" }, { "model": "siprotec \u003cen100 ethernet", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "44.29" }, { "model": "reyrolle", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "0" }, { "model": "softnet profinet io", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec compact", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7ut686", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7sj686", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7sj66", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec 7sd686", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "siprotec", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "40" }, { "model": "modbus tcp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "iec", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1040" }, { "model": "en100 ethernet module", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.20" }, { "model": "dnp3 tcp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "profinet io", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1.4.1" }, { "model": "en100", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.29.1" }, { "model": "en100", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.29" }, { "model": "en100 ethernet module", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.29" }, { "model": "en100 ethernet module", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.20" }, { "model": "en100 ethernet module", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.29.1" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "en100 ethernet module", "version": "4.28" } ], "sources": [ { "db": "IVD", "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17" }, { "db": "CNVD", "id": "CNVD-2016-07253" }, { "db": "BID", "id": "92748" }, { "db": "BID", "id": "99471" }, { "db": "JVNDB", "id": "JVNDB-2016-004538" }, { "db": "CNNVD", "id": "CNNVD-201609-041" }, { "db": "NVD", "id": "CVE-2016-7113" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/h:siemens:en100_ethernet_module", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:en100_ethernet_module_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2016-004538" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The vendor reported this issue.", "sources": [ { "db": "BID", "id": "92748" } ], "trust": 0.3 }, "cve": "CVE-2016-7113", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2016-7113", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2016-07253", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-95933", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2016-7113", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.8, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2016-7113", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2016-7113", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2016-07253", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201609-041", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-95933", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17" }, { "db": "CNVD", "id": "CNVD-2016-07253" }, { "db": "VULHUB", "id": "VHN-95933" }, { "db": "JVNDB", "id": "JVNDB-2016-004538" }, { "db": "CNNVD", "id": "CNNVD-201609-041" }, { "db": "NVD", "id": "CVE-2016-7113" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode. Siemens SIPROTEC 4 and SIPROTEC Compact For devices EN100 Ethernet Module contains service disruption ( Transition to defect mode (defect-mode transition)) There are vulnerabilities that are put into a state.Skillfully crafted by a third party HTTP Service disruption via packets ( Transition to defect mode (defect-mode transition)) There is a possibility of being put into a state. SIPROTEC 4 and SIPROTEC Compact devices offer a wide range of centralized protection, control and automation functions for substations and other applications. Siemens SIPROTEC 4, SIPROTEC Compact, a denial of service vulnerability exists in versions prior to EN100 Ethernet 4.29. A remote attacker can cause a denial of service by constructing an HTTP packet. \nAn attacker can exploit this issue to cause denial-of-service conditions. EN100 Ethernet Modules for Reyrolle is prone to the following security vulnerabilities: :\n1. Multiple information-disclosure vulnerabilities\n2. A denial-of-service vulnerability\n3. Multiple authentication-bypass vulnerabilities\nAn attacker may leverage these issues to disclose sensitive information, perform certain unauthorized actions actions, gain unauthorized access, or bypass certain security restrictions and cause a denial-of-service condition. Both Siemens SIPROTEC 4 and SIPROTEC Compact are products of Siemens, Germany. Siemens SIPROTEC 4 is a series of multifunctional relays with a friendly man-machine interface. SIPROTEC Compact is a microcomputer protection device", "sources": [ { "db": "NVD", "id": "CVE-2016-7113" }, { "db": "JVNDB", "id": "JVNDB-2016-004538" }, { "db": "CNVD", "id": "CNVD-2016-07253" }, { "db": "BID", "id": "92748" }, { "db": "BID", "id": "99471" }, { "db": "IVD", "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17" }, { "db": "VULHUB", "id": "VHN-95933" } ], "trust": 2.97 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2016-7113", "trust": 3.9 }, { "db": "SIEMENS", "id": "SSA-630413", "trust": 2.6 }, { "db": "ICS CERT", "id": "ICSA-17-187-03", "trust": 2.2 }, { "db": "BID", "id": "92748", "trust": 2.0 }, { "db": "BID", "id": "99471", "trust": 1.4 }, { "db": "SIEMENS", "id": "SSA-323211", "trust": 1.1 }, { "db": "ICS CERT", "id": "ICSA-16-250-01", "trust": 1.1 }, { "db": "CNNVD", "id": "CNNVD-201609-041", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2016-07253", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-17-334-01", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2016-004538", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-17-187-02", "trust": 0.6 }, { "db": "NSFOCUS", "id": "34719", "trust": 0.6 }, { "db": "IVD", "id": "8829001C-06EF-4F0D-A415-C3CC2278FA17", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-95933", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17" }, { "db": "CNVD", "id": "CNVD-2016-07253" }, { "db": "VULHUB", "id": "VHN-95933" }, { "db": "BID", "id": "92748" }, { "db": "BID", "id": "99471" }, { "db": "JVNDB", "id": "JVNDB-2016-004538" }, { "db": "CNNVD", "id": "CNNVD-201609-041" }, { "db": "NVD", "id": "CVE-2016-7113" } ] }, "id": "VAR-201609-0492", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17" }, { "db": "CNVD", "id": "CNVD-2016-07253" }, { "db": "VULHUB", "id": "VHN-95933" } ], "trust": 1.646969684 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17" }, { "db": "CNVD", "id": "CNVD-2016-07253" } ] }, "last_update_date": "2024-11-23T22:13:28.517000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-630413", "trust": 0.8, "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf" }, { "title": "Siemens SIPROTEC 4/SIPROTEC Compact denial of service vulnerability patch", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/81147" }, { "title": "Siemens SIPROTEC 4 and SIPROTEC Compact EN100 Ethernet Repair measures for module security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=63878" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2016-07253" }, { "db": "JVNDB", "id": "JVNDB-2016-004538" }, { "db": "CNNVD", "id": "CNNVD-201609-041" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-399", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-95933" }, { "db": "JVNDB", "id": "JVNDB-2016-004538" }, { "db": "NVD", "id": "CVE-2016-7113" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf" }, { "trust": 2.2, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-187-03" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/92748" }, { "trust": 1.1, "url": "http://www.securityfocus.com/bid/99471" }, { "trust": 1.1, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-323211.pdf" }, { "trust": 1.1, "url": "https://ics-cert.us-cert.gov/advisories/icsa-16-250-01" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-7113" }, { "trust": 0.8, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-334-01" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-7113" }, { "trust": 0.6, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-187-02" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/34719" }, { "trust": 0.3, "url": "http://www.siemens.com/" }, { "trust": 0.3, "url": "http://subscriber.communications.siemens.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2016-07253" }, { "db": "VULHUB", "id": "VHN-95933" }, { "db": "BID", "id": "92748" }, { "db": "BID", "id": "99471" }, { "db": "JVNDB", "id": "JVNDB-2016-004538" }, { "db": "CNNVD", "id": "CNNVD-201609-041" }, { "db": "NVD", "id": "CVE-2016-7113" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17" }, { "db": "CNVD", "id": "CNVD-2016-07253" }, { "db": "VULHUB", "id": "VHN-95933" }, { "db": "BID", "id": "92748" }, { "db": "BID", "id": "99471" }, { "db": "JVNDB", "id": "JVNDB-2016-004538" }, { "db": "CNNVD", "id": "CNNVD-201609-041" }, { "db": "NVD", "id": "CVE-2016-7113" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-09-06T00:00:00", "db": "IVD", "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17" }, { "date": "2016-09-06T00:00:00", "db": "CNVD", "id": "CNVD-2016-07253" }, { "date": "2016-09-06T00:00:00", "db": "VULHUB", "id": "VHN-95933" }, { "date": "2016-09-05T00:00:00", "db": "BID", "id": "92748" }, { "date": "2017-07-06T00:00:00", "db": "BID", "id": "99471" }, { "date": "2016-09-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2016-004538" }, { "date": "2016-09-06T00:00:00", "db": "CNNVD", "id": "CNNVD-201609-041" }, { "date": "2016-09-06T00:59:01.883000", "db": "NVD", "id": "CVE-2016-7113" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2016-09-07T00:00:00", "db": "CNVD", "id": "CNVD-2016-07253" }, { "date": "2018-03-23T00:00:00", "db": "VULHUB", "id": "VHN-95933" }, { "date": "2017-07-11T12:06:00", "db": "BID", "id": "92748" }, { "date": "2017-07-06T00:00:00", "db": "BID", "id": "99471" }, { "date": "2017-12-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2016-004538" }, { "date": "2016-09-06T00:00:00", "db": "CNNVD", "id": "CNNVD-201609-041" }, { "date": "2024-11-21T02:57:29.400000", "db": "NVD", "id": "CVE-2016-7113" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "network", "sources": [ { "db": "BID", "id": "92748" }, { "db": "BID", "id": "99471" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIPROTEC 4/SIPROTEC Compact Denial of service vulnerability", "sources": [ { "db": "IVD", "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17" }, { "db": "CNVD", "id": "CNVD-2016-07253" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Resource management error", "sources": [ { "db": "IVD", "id": "8829001c-06ef-4f0d-a415-c3cc2278fa17" }, { "db": "CNNVD", "id": "CNNVD-201609-041" } ], "trust": 0.8 } }
gsd-2016-7113
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2016-7113", "description": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.", "id": "GSD-2016-7113" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2016-7113" ], "details": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.", "id": "GSD-2016-7113", "modified": "2023-12-13T01:21:20.862984Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "DATE_PUBLIC": "2017-07-04T00:00:00", "ID": "CVE-2016-7113", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "92748", "refsource": "BID", "url": "http://www.securityfocus.com/bid/92748" }, { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf", "refsource": "CONFIRM", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf" }, { "name": "99471", "refsource": "BID", "url": "http://www.securityfocus.com/bid/99471" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:en100_ethernet_module_firmware:4.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:en100_ethernet_module:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2016-7113" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-399" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf" }, { "name": "92748", "refsource": "BID", "tags": [], "url": "http://www.securityfocus.com/bid/92748" }, { "name": "99471", "refsource": "BID", "tags": [], "url": "http://www.securityfocus.com/bid/99471" }, { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf", "refsource": "CONFIRM", "tags": [], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03", "refsource": "MISC", "tags": [], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": true, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2018-03-23T01:29Z", "publishedDate": "2016-09-06T00:59Z" } } }
icsa-17-187-03f
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to NCCIC when they made firmware available to fix them" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Remotely exploitable/low skill level to exploit.", "title": "Risk evaluation" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the NCCIC Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT website.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "In addition, NCCIC recommends that users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on vulnerabilities in Siemens products and solutions,\nplease contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "general", "text": "For further inquiries on vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-187-03F JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-187-03f.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-187-03F Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-03f" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-03f" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/" }, { "category": "external", "summary": "SSA-496604: SSA-323211: Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact Devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/SSA-323211.txt" } ], "title": "Siemens SIPROTEC 4 and SIPROTEC Compact (Update F)", "tracking": { "current_release_date": "2018-03-20T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-187-03F", "initial_release_date": "2017-07-06T00:00:00.000000Z", "revision_history": [ { "date": "2017-07-06T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-187-03 Siemens SIPROTEC 4 and SIPROTEC Compact Devices" }, { "date": "2017-07-18T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-17-187-03A Siemens SIPROTEC 4 and SIPROTEC Compact (Update A)" }, { "date": "2017-07-27T00:00:00.000000Z", "legacy_version": "B", "number": "3", "summary": "ICSA-17-187-03B Siemens SIPROTEC 4 and SIPROTEC Compact (Update B)" }, { "date": "2017-10-10T00:00:00.000000Z", "legacy_version": "C", "number": "4", "summary": "ICSA-17-187-03C Siemens SIPROTEC 4 and SIPROTEC Compact (Update C)" }, { "date": "2017-11-30T00:00:00.000000Z", "legacy_version": "D", "number": "5", "summary": "ICSA-17-187-03D Siemens SIPROTEC 4 and SIPROTEC Compact (Update D)" }, { "date": "2018-01-04T00:00:00.000000Z", "legacy_version": "E", "number": "6", "summary": "ICSA-17-187-03E Siemens SIPROTEC 4 and SIPROTEC Compact (Update E)" }, { "date": "2018-03-20T00:00:00.000000Z", "legacy_version": "F", "number": "7", "summary": "ICSA-17-187-03F Siemens SIPROTEC 4 and SIPROTEC Compact (Update F)" } ], "status": "final", "version": "7" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.04.01", "product": { "name": "Firmware variant PROFINET IO for EN100 Ethernet module: All versions \u003c V1.04.01", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Firmware variant PROFINET IO for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.11.00", "product": { "name": "Firmware variant Modbus TCP for EN100 Ethernet module: All versions \u003c V1.11.00", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Firmware variant Modbus TCP for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.03", "product": { "name": "Firmware variant DNP3 TCP for EN100 Ethernet module: All versions \u003c V1.03", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Firmware variant DNP3 TCP for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.21", "product": { "name": "Firmware variant IEC 104 for EN100 Ethernet module: All versions \u003c V1.21", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Firmware variant IEC 104 for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c 1.02.02", "product": { "name": "EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80: All versions \u003c 1.02.02", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.83", "product": { "name": "SIPROTEC 7SJ686: All versions \u003c V 4.83", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "SIPROTEC 7SJ686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.87", "product": { "name": "SIPROTEC 7SJ686: All versions \u003c V 4.87", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "SIPROTEC 7SJ686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.01", "product": { "name": "SIPROTEC 7UT686: All versions \u003c V 4.01", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "SIPROTEC 7UT686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.02", "product": { "name": "SIPROTEC 7UT686: All versions \u003c V 4.02", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "SIPROTEC 7UT686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.03", "product": { "name": "SIPROTEC 7SD686: All versions \u003c V 4.03", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "SIPROTEC 7SD686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.05", "product": { "name": "SIPROTEC 7SD686: All versions \u003c V 4.05", "product_id": "CSAFPID-00011" } } ], "category": "product_name", "name": "SIPROTEC 7SD686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.20", "product": { "name": "SIPROTEC 7SJ66: All versions \u003c V 4.20", "product_id": "CSAFPID-00012" } } ], "category": "product_name", "name": "SIPROTEC 7SJ66" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.30", "product": { "name": "SIPROTEC 7SJ66: All versions \u003c V 4.30", "product_id": "CSAFPID-00013" } } ], "category": "product_name", "name": "SIPROTEC 7SJ66" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2015-5374", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2015-5374" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:H/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-4784", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4784" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V 4.83 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51 ", "product_ids": [ "CSAFPID-0006" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51" }, { "category": "vendor_fix", "details": "Install V 4.01 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68 ", "product_ids": [ "CSAFPID-0008" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68" }, { "category": "vendor_fix", "details": "Install V 4.03 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64 ", "product_ids": [ "CSAFPID-00010" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64" }, { "category": "vendor_fix", "details": "Install V 4.20 - Download: https://support.industry.siemens.com/cs/gb/en/view/109743555 ", "product_ids": [ "CSAFPID-00012" ], "url": "https://support.industry.siemens.com/cs/gb/en/view/109743555" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-4785", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (port 80/tcp) of the affected devices could allow remoteattackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4785" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7112", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7112" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7113", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7113" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7114", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7114" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V 4.87 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51 ", "product_ids": [ "CSAFPID-0007" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51" }, { "category": "vendor_fix", "details": "Install V4.02 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68 ", "product_ids": [ "CSAFPID-0009" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68" }, { "category": "vendor_fix", "details": "Install V4.05 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64 ", "product_ids": [ "CSAFPID-00011" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64" }, { "category": "vendor_fix", "details": "Install V 4.30 - Download: https://support.industry.siemens.com/cs/us/en/view/109743555 ", "product_ids": [ "CSAFPID-00013" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] } ] }
ICSA-17-187-03F
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to NCCIC when they made firmware available to fix them" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Remotely exploitable/low skill level to exploit.", "title": "Risk evaluation" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the NCCIC Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT website.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "In addition, NCCIC recommends that users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on vulnerabilities in Siemens products and solutions,\nplease contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "general", "text": "For further inquiries on vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-187-03F JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-187-03f.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-187-03F Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-03f" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-03f" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/" }, { "category": "external", "summary": "SSA-496604: SSA-323211: Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact Devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/SSA-323211.txt" } ], "title": "Siemens SIPROTEC 4 and SIPROTEC Compact (Update F)", "tracking": { "current_release_date": "2018-03-20T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-187-03F", "initial_release_date": "2017-07-06T00:00:00.000000Z", "revision_history": [ { "date": "2017-07-06T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-187-03 Siemens SIPROTEC 4 and SIPROTEC Compact Devices" }, { "date": "2017-07-18T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-17-187-03A Siemens SIPROTEC 4 and SIPROTEC Compact (Update A)" }, { "date": "2017-07-27T00:00:00.000000Z", "legacy_version": "B", "number": "3", "summary": "ICSA-17-187-03B Siemens SIPROTEC 4 and SIPROTEC Compact (Update B)" }, { "date": "2017-10-10T00:00:00.000000Z", "legacy_version": "C", "number": "4", "summary": "ICSA-17-187-03C Siemens SIPROTEC 4 and SIPROTEC Compact (Update C)" }, { "date": "2017-11-30T00:00:00.000000Z", "legacy_version": "D", "number": "5", "summary": "ICSA-17-187-03D Siemens SIPROTEC 4 and SIPROTEC Compact (Update D)" }, { "date": "2018-01-04T00:00:00.000000Z", "legacy_version": "E", "number": "6", "summary": "ICSA-17-187-03E Siemens SIPROTEC 4 and SIPROTEC Compact (Update E)" }, { "date": "2018-03-20T00:00:00.000000Z", "legacy_version": "F", "number": "7", "summary": "ICSA-17-187-03F Siemens SIPROTEC 4 and SIPROTEC Compact (Update F)" } ], "status": "final", "version": "7" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.04.01", "product": { "name": "Firmware variant PROFINET IO for EN100 Ethernet module: All versions \u003c V1.04.01", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Firmware variant PROFINET IO for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.11.00", "product": { "name": "Firmware variant Modbus TCP for EN100 Ethernet module: All versions \u003c V1.11.00", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Firmware variant Modbus TCP for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.03", "product": { "name": "Firmware variant DNP3 TCP for EN100 Ethernet module: All versions \u003c V1.03", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Firmware variant DNP3 TCP for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V1.21", "product": { "name": "Firmware variant IEC 104 for EN100 Ethernet module: All versions \u003c V1.21", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Firmware variant IEC 104 for EN100 Ethernet module" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c 1.02.02", "product": { "name": "EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80: All versions \u003c 1.02.02", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.83", "product": { "name": "SIPROTEC 7SJ686: All versions \u003c V 4.83", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "SIPROTEC 7SJ686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.87", "product": { "name": "SIPROTEC 7SJ686: All versions \u003c V 4.87", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "SIPROTEC 7SJ686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.01", "product": { "name": "SIPROTEC 7UT686: All versions \u003c V 4.01", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "SIPROTEC 7UT686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.02", "product": { "name": "SIPROTEC 7UT686: All versions \u003c V 4.02", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "SIPROTEC 7UT686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.03", "product": { "name": "SIPROTEC 7SD686: All versions \u003c V 4.03", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "SIPROTEC 7SD686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.05", "product": { "name": "SIPROTEC 7SD686: All versions \u003c V 4.05", "product_id": "CSAFPID-00011" } } ], "category": "product_name", "name": "SIPROTEC 7SD686" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.20", "product": { "name": "SIPROTEC 7SJ66: All versions \u003c V 4.20", "product_id": "CSAFPID-00012" } } ], "category": "product_name", "name": "SIPROTEC 7SJ66" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V 4.30", "product": { "name": "SIPROTEC 7SJ66: All versions \u003c V 4.30", "product_id": "CSAFPID-00013" } } ], "category": "product_name", "name": "SIPROTEC 7SJ66" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2015-5374", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2015-5374" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:H/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-4784", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4784" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V 4.83 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51 ", "product_ids": [ "CSAFPID-0006" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51" }, { "category": "vendor_fix", "details": "Install V 4.01 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68 ", "product_ids": [ "CSAFPID-0008" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68" }, { "category": "vendor_fix", "details": "Install V 4.03 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64 ", "product_ids": [ "CSAFPID-00010" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64" }, { "category": "vendor_fix", "details": "Install V 4.20 - Download: https://support.industry.siemens.com/cs/gb/en/view/109743555 ", "product_ids": [ "CSAFPID-00012" ], "url": "https://support.industry.siemens.com/cs/gb/en/view/109743555" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-4785", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (port 80/tcp) of the affected devices could allow remoteattackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4785" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7112", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7112" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7113", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7113" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] }, { "cve": "CVE-2016-7114", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device\u0027s web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, "references": [ { "category": "external", "summary": "https://support.industry.siemens.com/cs/us/en/view/109743555", "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7114" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Apply secure substation concept and Defense-in-Depth (see\nhttps://www.siemens.com/gridsecurity)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Restrict network access to port 80/TCP and port 50000/UDP", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] }, { "category": "vendor_fix", "details": "Install V1.04.01 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.11.00 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0002" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.03 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V1.21 - Download: https://support.industry.siemens.com/cs/us/en/view/109745821 ", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109745821" }, { "category": "vendor_fix", "details": "Install V 4.87 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51 ", "product_ids": [ "CSAFPID-0007" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=51" }, { "category": "vendor_fix", "details": "Install V4.02 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68 ", "product_ids": [ "CSAFPID-0009" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=68" }, { "category": "vendor_fix", "details": "Install V4.05 - Download: http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64 ", "product_ids": [ "CSAFPID-00011" ], "url": "http://www.siemensenergysector.com/ProductRelatedDown.aspx?ProductId=64" }, { "category": "vendor_fix", "details": "Install V 4.30 - Download: https://support.industry.siemens.com/cs/us/en/view/109743555 ", "product_ids": [ "CSAFPID-00013" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109743555" }, { "category": "mitigation", "details": "As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Secure Substations can be found at: https://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010", "CSAFPID-00011", "CSAFPID-00012", "CSAFPID-00013" ] } ] } ] }
icsa-17-187-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to ICS-CERT when they made firmware available to fix them" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Remotely exploitable/low skill level to exploit.", "title": "Risk evaluation" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-187-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-187-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-187-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-02" } ], "title": "Siemens Reyrolle", "tracking": { "current_release_date": "2017-07-06T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-187-02", "initial_release_date": "2017-07-06T00:00:00.000000Z", "revision_history": [ { "date": "2017-07-06T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-187-02 Siemens Reyrolle" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 4.29.01", "product": { "name": "EN100 Ethernet modules as optional for Reyrolle: All versions prior to V4.29.01", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "EN100 Ethernet modules as optional for Reyrolle" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-4784", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (Port 80/TCP) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.CVE-2016-4784 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4784" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released a new firmware version (V4.29.01) to address these vulnerabilities. It can be found at the SIPROTEC 4 downloads area at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/downloads/siprotec-4", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/downloads/siprotec-4" }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms such as firewalls, segmentation, and VPN. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security. Please see the specific product manual for more information. Manuals can be obtained from the downloads menu at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/gridsecurity" }, { "category": "vendor_fix", "details": "For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-452237 at the following location:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2016-4785", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (Port 80/TCP) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained.CVE-2016-4785 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4785" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released a new firmware version (V4.29.01) to address these vulnerabilities. It can be found at the SIPROTEC 4 downloads area at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/downloads/siprotec-4", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/downloads/siprotec-4" }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms such as firewalls, segmentation, and VPN. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security. Please see the specific product manual for more information. Manuals can be obtained from the downloads menu at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/gridsecurity" }, { "category": "vendor_fix", "details": "For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-452237 at the following location:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2016-7112", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device \u0027s web interface (Port 80/TCP) could possibly circumvent authentication and perform certain administrative operations.CVE-2016-7112 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7112" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released a new firmware version (V4.29.01) to address these vulnerabilities. It can be found at the SIPROTEC 4 downloads area at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/downloads/siprotec-4", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/downloads/siprotec-4" }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms such as firewalls, segmentation, and VPN. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security. Please see the specific product manual for more information. Manuals can be obtained from the downloads menu at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/gridsecurity" }, { "category": "vendor_fix", "details": "For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-452237 at the following location:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2016-7113", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to Port 80/TCP could cause the affected device to go into defect mode.CVE-2016-7113 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7113" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released a new firmware version (V4.29.01) to address these vulnerabilities. It can be found at the SIPROTEC 4 downloads area at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/downloads/siprotec-4", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/downloads/siprotec-4" }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms such as firewalls, segmentation, and VPN. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security. Please see the specific product manual for more information. Manuals can be obtained from the downloads menu at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/gridsecurity" }, { "category": "vendor_fix", "details": "For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-452237 at the following location:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2016-7114", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device \u0027s web interface (Port 80/TCP) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.CVE-2016-7114 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7114" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released a new firmware version (V4.29.01) to address these vulnerabilities. It can be found at the SIPROTEC 4 downloads area at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/downloads/siprotec-4", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/downloads/siprotec-4" }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms such as firewalls, segmentation, and VPN. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security. Please see the specific product manual for more information. Manuals can be obtained from the downloads menu at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/gridsecurity" }, { "category": "vendor_fix", "details": "For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-452237 at the following location:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
icsa-17-334-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to ICS-CERT" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Remotely exploitable/low skill level to exploit.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-334-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-334-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-334-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-334-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-334-01" } ], "title": "Siemens SWT3000", "tracking": { "current_release_date": "2017-11-30T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-334-01", "initial_release_date": "2017-11-30T00:00:00.000000Z", "revision_history": [ { "date": "2017-11-30T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-334-01 Siemens SWT3000" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 01.01.00", "product": { "name": "TPOP firmware: All versions prior to V01.01.00", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "TPOP firmware" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 4.29.01", "product": { "name": "IEC 61850 firmware: All versions prior to V4.29.01", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "IEC 61850 firmware" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-4784", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "The integrated web server (Port 80/TCP) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained. SWT3000 with TPOP is not affected by this vulnerability.CVE-2016-4784 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4784" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has provided updated firmware that fixes the vulnerabilities for the following affected products and recommends users update to the newest version:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "To obtain the firmware please contact the Customer Support Center:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "support.energy@siemens.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Please note that not all of the devices above are affected by all vulnerabilities. For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-350846 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-4785", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "The integrated web server (Port 80/TCP) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. SWT3000 with TPOP is not affected by this vulnerability.CVE-2016-4785 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4785" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has provided updated firmware that fixes the vulnerabilities for the following affected products and recommends users update to the newest version:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "To obtain the firmware please contact the Customer Support Center:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "support.energy@siemens.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Please note that not all of the devices above are affected by all vulnerabilities. For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-350846 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-7112", "cwe": { "id": "CWE-288", "name": "Authentication Bypass Using an Alternate Path or Channel" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device \u0027s web interface (Port 80/TCP) could possibly circumvent authentication and perform certain administrative operations.CVE-2016-7112 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7112" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has provided updated firmware that fixes the vulnerabilities for the following affected products and recommends users update to the newest version:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "To obtain the firmware please contact the Customer Support Center:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "support.energy@siemens.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Please note that not all of the devices above are affected by all vulnerabilities. For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-350846 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-7113", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to Port 80/TCP could cause the affected EN100 module of the SWT3000 to go into defect mode.CVE-2016-7113 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7113" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has provided updated firmware that fixes the vulnerabilities for the following affected products and recommends users update to the newest version:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "To obtain the firmware please contact the Customer Support Center:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "support.energy@siemens.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Please note that not all of the devices above are affected by all vulnerabilities. For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-350846 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-7114", "cwe": { "id": "CWE-288", "name": "Authentication Bypass Using an Alternate Path or Channel" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device \u0027s web interface (Port 80/TCP) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.CVE-2016-7114 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7114" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has provided updated firmware that fixes the vulnerabilities for the following affected products and recommends users update to the newest version:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "To obtain the firmware please contact the Customer Support Center:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "support.energy@siemens.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Please note that not all of the devices above are affected by all vulnerabilities. For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-350846 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }
ICSA-17-187-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to ICS-CERT when they made firmware available to fix them" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Remotely exploitable/low skill level to exploit.", "title": "Risk evaluation" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-187-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-187-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-187-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-187-02" } ], "title": "Siemens Reyrolle", "tracking": { "current_release_date": "2017-07-06T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-187-02", "initial_release_date": "2017-07-06T00:00:00.000000Z", "revision_history": [ { "date": "2017-07-06T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-187-02 Siemens Reyrolle" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 4.29.01", "product": { "name": "EN100 Ethernet modules as optional for Reyrolle: All versions prior to V4.29.01", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "EN100 Ethernet modules as optional for Reyrolle" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-4784", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (Port 80/TCP) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.CVE-2016-4784 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4784" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released a new firmware version (V4.29.01) to address these vulnerabilities. It can be found at the SIPROTEC 4 downloads area at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/downloads/siprotec-4", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/downloads/siprotec-4" }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms such as firewalls, segmentation, and VPN. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security. Please see the specific product manual for more information. Manuals can be obtained from the downloads menu at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/gridsecurity" }, { "category": "vendor_fix", "details": "For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-452237 at the following location:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2016-4785", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "The integrated web server (Port 80/TCP) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained.CVE-2016-4785 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4785" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released a new firmware version (V4.29.01) to address these vulnerabilities. It can be found at the SIPROTEC 4 downloads area at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/downloads/siprotec-4", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/downloads/siprotec-4" }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms such as firewalls, segmentation, and VPN. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security. Please see the specific product manual for more information. Manuals can be obtained from the downloads menu at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/gridsecurity" }, { "category": "vendor_fix", "details": "For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-452237 at the following location:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2016-7112", "cwe": { "id": "CWE-862", "name": "Missing Authorization" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device \u0027s web interface (Port 80/TCP) could possibly circumvent authentication and perform certain administrative operations.CVE-2016-7112 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7112" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released a new firmware version (V4.29.01) to address these vulnerabilities. It can be found at the SIPROTEC 4 downloads area at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/downloads/siprotec-4", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/downloads/siprotec-4" }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms such as firewalls, segmentation, and VPN. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security. Please see the specific product manual for more information. Manuals can be obtained from the downloads menu at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/gridsecurity" }, { "category": "vendor_fix", "details": "For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-452237 at the following location:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2016-7113", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to Port 80/TCP could cause the affected device to go into defect mode.CVE-2016-7113 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7113" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released a new firmware version (V4.29.01) to address these vulnerabilities. It can be found at the SIPROTEC 4 downloads area at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/downloads/siprotec-4", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/downloads/siprotec-4" }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms such as firewalls, segmentation, and VPN. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security. Please see the specific product manual for more information. Manuals can be obtained from the downloads menu at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/gridsecurity" }, { "category": "vendor_fix", "details": "For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-452237 at the following location:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2016-7114", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device \u0027s web interface (Port 80/TCP) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.CVE-2016-7114 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7114" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has released a new firmware version (V4.29.01) to address these vulnerabilities. It can be found at the SIPROTEC 4 downloads area at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/downloads/siprotec-4", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/downloads/siprotec-4" }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms such as firewalls, segmentation, and VPN. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security. Please see the specific product manual for more information. Manuals can be obtained from the downloads menu at the following Siemens web site:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/gridsecurity", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/gridsecurity" }, { "category": "vendor_fix", "details": "For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-452237 at the following location:", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ICSA-17-334-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to ICS-CERT" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "ATTENTION: Remotely exploitable/low skill level to exploit.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "NCCIC/ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available in the ICS -CERT Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-17-334-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2017/icsa-17-334-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-17-334-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-334-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-17-334-01" } ], "title": "Siemens SWT3000", "tracking": { "current_release_date": "2017-11-30T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-17-334-01", "initial_release_date": "2017-11-30T00:00:00.000000Z", "revision_history": [ { "date": "2017-11-30T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-17-334-01 Siemens SWT3000" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 01.01.00", "product": { "name": "TPOP firmware: All versions prior to V01.01.00", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "TPOP firmware" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 4.29.01", "product": { "name": "IEC 61850 firmware: All versions prior to V4.29.01", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "IEC 61850 firmware" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2016-4784", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "The integrated web server (Port 80/TCP) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained. SWT3000 with TPOP is not affected by this vulnerability.CVE-2016-4784 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4784" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has provided updated firmware that fixes the vulnerabilities for the following affected products and recommends users update to the newest version:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "To obtain the firmware please contact the Customer Support Center:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "support.energy@siemens.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Please note that not all of the devices above are affected by all vulnerabilities. For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-350846 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-4785", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "The integrated web server (Port 80/TCP) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. SWT3000 with TPOP is not affected by this vulnerability.CVE-2016-4785 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-4785" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has provided updated firmware that fixes the vulnerabilities for the following affected products and recommends users update to the newest version:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "To obtain the firmware please contact the Customer Support Center:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "support.energy@siemens.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Please note that not all of the devices above are affected by all vulnerabilities. For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-350846 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-7112", "cwe": { "id": "CWE-288", "name": "Authentication Bypass Using an Alternate Path or Channel" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device \u0027s web interface (Port 80/TCP) could possibly circumvent authentication and perform certain administrative operations.CVE-2016-7112 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7112" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has provided updated firmware that fixes the vulnerabilities for the following affected products and recommends users update to the newest version:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "To obtain the firmware please contact the Customer Support Center:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "support.energy@siemens.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Please note that not all of the devices above are affected by all vulnerabilities. For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-350846 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-7113", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "Specially crafted packets sent to Port 80/TCP could cause the affected EN100 module of the SWT3000 to go into defect mode.CVE-2016-7113 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7113" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has provided updated firmware that fixes the vulnerabilities for the following affected products and recommends users update to the newest version:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "To obtain the firmware please contact the Customer Support Center:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "support.energy@siemens.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Please note that not all of the devices above are affected by all vulnerabilities. For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-350846 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] }, { "cve": "CVE-2016-7114", "cwe": { "id": "CWE-288", "name": "Authentication Bypass Using an Alternate Path or Channel" }, "notes": [ { "category": "summary", "text": "Attackers with network access to the device \u0027s web interface (Port 80/TCP) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful.CVE-2016-7114 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2016-7114" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Siemens has provided updated firmware that fixes the vulnerabilities for the following affected products and recommends users update to the newest version:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "To obtain the firmware please contact the Customer Support Center:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "support.energy@siemens.com", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Siemens recommends users protect network access with appropriate mechanisms. Siemens also advises that users configure the operational environment according to Siemens \u0027 Operational Guidelines for Industrial Security:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "https://www.siemens.com/cert/operational-guidelines-industrial-security", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.siemens.com/cert/operational-guidelines-industrial-security" }, { "category": "vendor_fix", "details": "Please note that not all of the devices above are affected by all vulnerabilities. For more information on these vulnerabilities and more detailed mitigation instructions, please see Siemens Security Advisory SSA-350846 at the following location:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "http://www.siemens.com/cert/advisories", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "http://www.siemens.com/cert/advisories" }, { "category": "vendor_fix", "details": "In addition, ICS-CERT recommends that users take the following measures to protect themselves from social engineering attacks:", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ] } ] }
ghsa-86wf-q4pv-q73v
Vulnerability from github
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.
{ "affected": [], "aliases": [ "CVE-2016-7113" ], "database_specific": { "cwe_ids": [], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2016-09-06T00:59:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 80/tcp could cause the affected device to go into defect mode.", "id": "GHSA-86wf-q4pv-q73v", "modified": "2022-05-14T03:35:57Z", "published": "2022-05-14T03:35:57Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2016-7113" }, { "type": "WEB", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03" }, { "type": "WEB", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/92748" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/99471" }, { "type": "WEB", "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "type": "CVSS_V3" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.