Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    3 vulnerabilities by enbra

    CVE-2021-34573 (GCVE-0-2021-34573)

    Vulnerability from cvelistv5 – Published: 2021-09-16 12:20 – Updated: 2024-09-17 02:21
    VLAI
    Title
    Incorrect calculation in Enbra EWM does not report backflows or no flow events
    Summary
    In Enbra EWM in Version 1.7.29 together with several tested wireless M-Bus Sensors the events backflow and "no flow" are not reconized or misinterpreted. This may lead to wrong values and missing events.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Enbra AT-WMBUS-16-2 Affected: all
    Create a notification for this product.
    Enbra ER-AM DN 15 Affected: ER-AM DN 15/SV all
    Affected: ER-AM DN 15/TV all
    Create a notification for this product.
    Enbra EWM 1.7.29 Affected: 03.11.2019
    Create a notification for this product.
    Date Public
    2021-08-31 00:00
    Credits
    Libor POLČÁK reported to CERT@VDE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:19:46.616Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34573.en"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AT-WMBUS-16-2",
              "vendor": "Enbra",
              "versions": [
                {
                  "status": "affected",
                  "version": "all"
                }
              ]
            },
            {
              "product": "ER-AM DN 15",
              "vendor": "Enbra",
              "versions": [
                {
                  "status": "affected",
                  "version": "ER-AM DN 15/SV all"
                },
                {
                  "status": "affected",
                  "version": "ER-AM DN 15/TV all"
                }
              ]
            },
            {
              "product": "EWM 1.7.29",
              "vendor": "Enbra",
              "versions": [
                {
                  "status": "affected",
                  "version": "03.11.2019"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Libor POL\u010c\u00c1K reported to CERT@VDE"
            }
          ],
          "datePublic": "2021-08-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "In Enbra EWM in Version 1.7.29 together with several tested wireless M-Bus Sensors the events backflow and \"no flow\" are not reconized or misinterpreted. This may lead to wrong values and missing events."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-682",
                  "description": "CWE-682 Incorrect Calculation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-09-16T12:20:18.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34573.en"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Incorrect calculation in Enbra EWM does not report backflows or no flow events",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2021-08-31T22:00:00.000Z",
              "ID": "CVE-2021-34573",
              "STATE": "PUBLIC",
              "TITLE": "Incorrect calculation in Enbra EWM does not report backflows or no flow events"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "AT-WMBUS-16-2",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "all"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "ER-AM DN 15",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "ER-AM DN 15/SV",
                                "version_value": "all"
                              },
                              {
                                "version_name": "ER-AM DN 15/TV",
                                "version_value": "all"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "EWM 1.7.29",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "03.11.2019"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Enbra"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Libor POL\u010c\u00c1K reported to CERT@VDE"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In Enbra EWM in Version 1.7.29 together with several tested wireless M-Bus Sensors the events backflow and \"no flow\" are not reconized or misinterpreted. This may lead to wrong values and missing events."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-682 Incorrect Calculation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34573.en",
                  "refsource": "CONFIRM",
                  "url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34573.en"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34573",
        "datePublished": "2021-09-16T12:20:18.226Z",
        "dateReserved": "2021-06-10T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:21:48.549Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34572 (GCVE-0-2021-34572)

    Vulnerability from cvelistv5 – Published: 2021-09-16 12:20 – Updated: 2024-09-16 17:23
    VLAI
    Title
    Insufficient Verification of Data Authenticity in Enbra EWM (replay attack)
    Summary
    Enbra EWM 1.7.29 does not check for or detect replay attacks sent by wireless M-Bus Security mode 5 devices. Instead timestamps of the sensor are replaced by the time of the readout even if the data is a replay of earlier data.
    CWE
    • CWE-345 - Insufficient Verification of Data Authenticity
    Assigner
    References
    Impacted products
    Vendor Product Version
    Enbra EWM 1.7.29 Affected: 03.11.2019
    Create a notification for this product.
    Date Public
    2021-08-31 00:00
    Credits
    Libor POLČÁK reported to CERT@VDE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:19:47.009Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34572.en"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EWM 1.7.29",
              "vendor": "Enbra",
              "versions": [
                {
                  "status": "affected",
                  "version": "03.11.2019"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Libor POL\u010c\u00c1K reported to CERT@VDE"
            }
          ],
          "datePublic": "2021-08-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Enbra EWM 1.7.29 does not check for or detect replay attacks sent by wireless M-Bus Security mode 5 devices. Instead timestamps of the sensor are replaced by the time of the readout even if the data is a replay of earlier data."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "CWE-345 Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-09-16T12:20:16.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34572.en"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Insufficient Verification of Data Authenticity in Enbra EWM (replay attack)",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2021-08-31T22:00:00.000Z",
              "ID": "CVE-2021-34572",
              "STATE": "PUBLIC",
              "TITLE": "Insufficient Verification of Data Authenticity in Enbra EWM (replay attack)"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "EWM 1.7.29",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "03.11.2019"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Enbra"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Libor POL\u010c\u00c1K reported to CERT@VDE"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Enbra EWM 1.7.29 does not check for or detect replay attacks sent by wireless M-Bus Security mode 5 devices. Instead timestamps of the sensor are replaced by the time of the readout even if the data is a replay of earlier data."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-345 Insufficient Verification of Data Authenticity"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34572.en",
                  "refsource": "CONFIRM",
                  "url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34572.en"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34572",
        "datePublished": "2021-09-16T12:20:16.725Z",
        "dateReserved": "2021-06-10T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:23:17.590Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34571 (GCVE-0-2021-34571)

    Vulnerability from cvelistv5 – Published: 2021-09-16 12:20 – Updated: 2024-09-16 16:13
    VLAI
    Title
    Hard-coded Credentials in Enbra Wireless M-Bus devices
    Summary
    Multiple Wireless M-Bus devices by Enbra use Hard-coded Credentials in Security mode 5 without an option to change the encryption key. An adversary can learn all information that is available in Enbra EWM.
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    References
    Impacted products
    Vendor Product Version
    Enbra AT-WMBUS-16-2 Unknown: all
    Create a notification for this product.
    Enbra ER-AM DN 15 Unknown: ER-AM DN 15/SV all
    Unknown: ER-AM DN 15/TV all
    Create a notification for this product.
    Enbra EWM 1.7.29 Affected: 03.11.2019
    Create a notification for this product.
    Date Public
    2021-08-31 00:00
    Credits
    Libor POLČÁK reported to CERT@VDE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.369Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34571.en"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AT-WMBUS-16-2",
              "vendor": "Enbra",
              "versions": [
                {
                  "status": "unknown",
                  "version": "all"
                }
              ]
            },
            {
              "product": "ER-AM DN 15",
              "vendor": "Enbra",
              "versions": [
                {
                  "status": "unknown",
                  "version": "ER-AM DN 15/SV all"
                },
                {
                  "status": "unknown",
                  "version": "ER-AM DN 15/TV all"
                }
              ]
            },
            {
              "product": "EWM 1.7.29",
              "vendor": "Enbra",
              "versions": [
                {
                  "status": "affected",
                  "version": "03.11.2019"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Libor POL\u010c\u00c1K reported to CERT@VDE"
            }
          ],
          "datePublic": "2021-08-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple Wireless M-Bus devices by Enbra use Hard-coded Credentials in Security mode 5 without an option to change the encryption key. An adversary can learn all information that is available in Enbra EWM."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-09-16T12:20:15.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34571.en"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Hard-coded Credentials in Enbra Wireless M-Bus devices",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2021-08-31T22:00:00.000Z",
              "ID": "CVE-2021-34571",
              "STATE": "PUBLIC",
              "TITLE": "Hard-coded Credentials in Enbra Wireless M-Bus devices"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "AT-WMBUS-16-2",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "?",
                                "version_value": "all"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "ER-AM DN 15",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "?",
                                "version_name": "ER-AM DN 15/SV",
                                "version_value": "all"
                              },
                              {
                                "version_affected": "?",
                                "version_name": "ER-AM DN 15/TV",
                                "version_value": "all"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "EWM 1.7.29",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "03.11.2019"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Enbra"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Libor POL\u010c\u00c1K reported to CERT@VDE"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple Wireless M-Bus devices by Enbra use Hard-coded Credentials in Security mode 5 without an option to change the encryption key. An adversary can learn all information that is available in Enbra EWM."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-798 Use of Hard-coded Credentials"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34571.en",
                  "refsource": "CONFIRM",
                  "url": "https://www.fit.vutbr.cz/~polcak/CVE-2021-34571.en"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34571",
        "datePublished": "2021-09-16T12:20:15.225Z",
        "dateReserved": "2021-06-10T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:13:55.210Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }