CVE-2025-2983 (GCVE-0-2025-2983)

Vulnerability from cvelistv5 – Published: 2025-03-31 08:00 – Updated: 2025-03-31 12:38
VLAI?
Title
Legrand SMS PowerView os command injection
Summary
A vulnerability has been found in Legrand SMS PowerView 1.x and classified as critical. Affected by this vulnerability is an unknown functionality. The manipulation of the argument redirect leads to os command injection. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CWE
Assigner
References
https://vuldb.com/?id.302035 vdb-entrytechnical-description
https://vuldb.com/?ctiid.302035 signaturepermissions-required
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2983",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-31T12:38:31.738934Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-31T12:38:50.834Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SMS PowerView",
          "vendor": "Legrand",
          "versions": [
            {
              "status": "affected",
              "version": "1.x"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Legrand SMS PowerView 1.x and classified as critical. Affected by this vulnerability is an unknown functionality. The manipulation of the argument redirect leads to os command injection. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Legrand SMS PowerView 1.x wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um eine nicht n\u00e4her bekannte Funktion. Durch Manipulieren des Arguments redirect mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.2,
            "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "OS Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-31T08:00:08.861Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-302035 | Legrand SMS PowerView os command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.302035"
        },
        {
          "name": "VDB-302035 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.302035"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-03-30T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-03-30T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-03-30T10:03:45.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Legrand SMS PowerView os command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-2983",
    "datePublished": "2025-03-31T08:00:08.861Z",
    "dateReserved": "2025-03-30T07:58:32.953Z",
    "dateUpdated": "2025-03-31T12:38:50.834Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2982 (GCVE-0-2025-2982)

Vulnerability from cvelistv5 – Published: 2025-03-31 07:31 – Updated: 2025-03-31 12:39
VLAI?
Title
Legrand SMS PowerView file inclusion
Summary
A vulnerability, which was classified as critical, was found in Legrand SMS PowerView 1.x. Affected is an unknown function. The manipulation of the argument redirect leads to file inclusion. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CWE
Assigner
References
https://vuldb.com/?id.302034 vdb-entrytechnical-description
https://vuldb.com/?ctiid.302034 signaturepermissions-required
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2982",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-31T12:39:16.942863Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-31T12:39:27.578Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SMS PowerView",
          "vendor": "Legrand",
          "versions": [
            {
              "status": "affected",
              "version": "1.x"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, was found in Legrand SMS PowerView 1.x. Affected is an unknown function. The manipulation of the argument redirect leads to file inclusion. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Legrand SMS PowerView 1.x gefunden. Sie wurde als kritisch eingestuft. Betroffen hiervon ist ein unbekannter Ablauf. Durch das Manipulieren des Arguments redirect mit unbekannten Daten kann eine file inclusion-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-73",
              "description": "File Inclusion",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-31T07:31:04.028Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-302034 | Legrand SMS PowerView file inclusion",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.302034"
        },
        {
          "name": "VDB-302034 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.302034"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-03-30T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-03-30T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-03-30T10:03:43.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Legrand SMS PowerView file inclusion"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-2982",
    "datePublished": "2025-03-31T07:31:04.028Z",
    "dateReserved": "2025-03-30T07:58:30.516Z",
    "dateUpdated": "2025-03-31T12:39:27.578Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2981 (GCVE-0-2025-2981)

Vulnerability from cvelistv5 – Published: 2025-03-31 07:00 – Updated: 2025-03-31 12:40
VLAI?
Title
Legrand SMS PowerView cross site scripting
Summary
A vulnerability, which was classified as problematic, has been found in Legrand SMS PowerView 1.x. This issue affects some unknown processing. The manipulation of the argument redirect leads to cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CWE
Assigner
References
https://vuldb.com/?id.302033 vdb-entrytechnical-description
https://vuldb.com/?ctiid.302033 signaturepermissions-required
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2981",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-31T12:40:10.543644Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-31T12:40:24.332Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SMS PowerView",
          "vendor": "Legrand",
          "versions": [
            {
              "status": "affected",
              "version": "1.x"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as problematic, has been found in Legrand SMS PowerView 1.x. This issue affects some unknown processing. The manipulation of the argument redirect leads to cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Legrand SMS PowerView 1.x entdeckt. Sie wurde als problematisch eingestuft. Betroffen davon ist ein unbekannter Prozess. Mittels Manipulieren des Arguments redirect mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "Cross Site Scripting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "Code Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-31T07:00:10.188Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-302033 | Legrand SMS PowerView cross site scripting",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.302033"
        },
        {
          "name": "VDB-302033 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.302033"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-03-30T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-03-30T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-03-30T10:03:42.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Legrand SMS PowerView cross site scripting"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-2981",
    "datePublished": "2025-03-31T07:00:10.188Z",
    "dateReserved": "2025-03-30T07:58:27.689Z",
    "dateUpdated": "2025-03-31T12:40:24.332Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2980 (GCVE-0-2025-2980)

Vulnerability from cvelistv5 – Published: 2025-03-31 06:31 – Updated: 2025-03-31 12:48
VLAI?
Title
Legrand SMS PowerView redirect
Summary
A vulnerability classified as problematic was found in Legrand SMS PowerView 1.x. This vulnerability affects unknown code. The manipulation of the argument redirect leads to open redirect. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CWE
Assigner
References
https://vuldb.com/?id.302032 vdb-entrytechnical-description
https://vuldb.com/?ctiid.302032 signaturepermissions-required
https://vuldb.com/?submit.523212 third-party-advisory
Impacted products
Credits
Fr1t0 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2980",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-31T12:48:50.643902Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-31T12:48:54.262Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://vuldb.com/?submit.523212"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SMS PowerView",
          "vendor": "Legrand",
          "versions": [
            {
              "status": "affected",
              "version": "1.x"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Fr1t0 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as problematic was found in Legrand SMS PowerView 1.x. This vulnerability affects unknown code. The manipulation of the argument redirect leads to open redirect. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Legrand SMS PowerView 1.x wurde eine Schwachstelle entdeckt. Sie wurde als problematisch eingestuft. Betroffen ist eine unbekannte Verarbeitung. Mittels dem Manipulieren des Arguments redirect mit unbekannten Daten kann eine open redirect-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 4,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "Open Redirect",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-31T06:31:03.825Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-302032 | Legrand SMS PowerView redirect",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.302032"
        },
        {
          "name": "VDB-302032 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.302032"
        },
        {
          "name": "Submit #523212 | Legrand SMS Power View 1.x.x OS Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.523212"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-03-30T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-03-30T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-03-30T10:03:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Legrand SMS PowerView redirect"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-2980",
    "datePublished": "2025-03-31T06:31:03.825Z",
    "dateReserved": "2025-03-30T07:58:25.420Z",
    "dateUpdated": "2025-03-31T12:48:54.262Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}