Vulnerabilites related to Mennekes - Smart / Premium charging stations
CVE-2025-22368 (GCVE-0-2025-22368)
Vulnerability from cvelistv5
Published
2025-03-11 13:40
Modified
2025-04-01 04:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/CVE-2025-22368 | third-party-advisory | |
https://csirt.divd.nl/DIVD-2025-00003 | vendor-advisory | |
https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf | release-notes |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Mennekes | Smart / Premium charging stations |
Version: * ≤ |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-22368", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-11T15:03:42.139099Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-11T15:03:48.901Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Smart / Premium charging stations", "vendor": "Mennekes", "versions": [ { "lessThan": "2.15", "status": "affected", "version": "*", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink(DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-03-10T14:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e" } ], "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS." } ], "impacts": [ { "capecId": "CAPEC-248", "descriptions": [ { "lang": "en", "value": "CAPEC-248 Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "NEGLIGIBLE", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-04-01T04:47:45.140Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2025-22368" }, { "tags": [ "vendor-advisory" ], "url": "https://csirt.divd.nl/DIVD-2025-00003" }, { "tags": [ "release-notes" ], "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf" } ], "source": { "discovery": "EXTERNAL" }, "title": "Mennekes smart/premium charges systems, Command injection in sCU firmware update", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2025-22368", "datePublished": "2025-03-11T13:40:22.216Z", "dateReserved": "2025-01-03T14:56:05.686Z", "dateUpdated": "2025-04-01T04:47:45.140Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-22369 (GCVE-0-2025-22369)
Vulnerability from cvelistv5
Published
2025-03-11 13:40
Modified
2025-04-01 04:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Summary
The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/CVE-2025-22369 | third-party-advisory | |
https://csirt.divd.nl/DIVD-2025-00003 | vendor-advisory | |
https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf | release-notes |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Mennekes | Smart / Premium charging stations |
Version: * ≤ |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-22369", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-11T14:52:14.627801Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-11T14:52:22.813Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Smart / Premium charging stations", "vendor": "Mennekes", "versions": [ { "lessThan": "2.15", "status": "affected", "version": "*", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink(DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-03-10T14:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e" } ], "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS." } ], "impacts": [ { "capecId": "CAPEC-597", "descriptions": [ { "lang": "en", "value": "CAPEC-597 Absolute Path Traversal" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "NEGLIGIBLE", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 7.1, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-552", "description": "CWE-552 Files or Directories Accessible to External Parties", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-04-01T04:47:47.988Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2025-22369" }, { "tags": [ "vendor-advisory" ], "url": "https://csirt.divd.nl/DIVD-2025-00003" }, { "tags": [ "release-notes" ], "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf" } ], "source": { "discovery": "EXTERNAL" }, "title": "Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2025-22369", "datePublished": "2025-03-11T13:40:24.403Z", "dateReserved": "2025-01-03T14:56:05.686Z", "dateUpdated": "2025-04-01T04:47:47.988Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-22366 (GCVE-0-2025-22366)
Vulnerability from cvelistv5
Published
2025-03-11 13:40
Modified
2025-04-01 04:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/CVE-2025-22366 | third-party-advisory | |
https://csirt.divd.nl/DIVD-2025-00003 | vendor-advisory | |
https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf | release-notes |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Mennekes | Smart / Premium charging stations |
Version: * ≤ |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-22366", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-11T14:53:28.425309Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-11T14:53:56.159Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Smart / Premium charging stations", "vendor": "Mennekes", "versions": [ { "lessThan": "2.15", "status": "affected", "version": "*", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink(DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-03-10T14:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e" } ], "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS." } ], "impacts": [ { "capecId": "CAPEC-248", "descriptions": [ { "lang": "en", "value": "CAPEC-248 Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "NEGLIGIBLE", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-04-01T04:47:47.110Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2025-22366" }, { "tags": [ "vendor-advisory" ], "url": "https://csirt.divd.nl/DIVD-2025-00003" }, { "tags": [ "release-notes" ], "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf" } ], "source": { "discovery": "EXTERNAL" }, "title": "Mennekes smart/premium charges systems, Command injection in firmware upgrade", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2025-22366", "datePublished": "2025-03-11T13:40:23.659Z", "dateReserved": "2025-01-03T14:56:05.685Z", "dateUpdated": "2025-04-01T04:47:47.110Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-22367 (GCVE-0-2025-22367)
Vulnerability from cvelistv5
Published
2025-03-11 13:40
Modified
2025-04-01 04:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/CVE-2025-22367 | third-party-advisory | |
https://csirt.divd.nl/DIVD-2025-00003 | vendor-advisory | |
https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf | release-notes |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Mennekes | Smart / Premium charging stations |
Version: * ≤ |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-22367", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-11T19:23:05.314995Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-11T19:23:24.531Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Smart / Premium charging stations", "vendor": "Mennekes", "versions": [ { "lessThan": "2.15", "status": "affected", "version": "*", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink(DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-03-10T14:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e" } ], "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS." } ], "impacts": [ { "capecId": "CAPEC-248", "descriptions": [ { "lang": "en", "value": "CAPEC-248 Command Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "NEGLIGIBLE", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "LOW", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-250", "description": "CWE-250", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-04-01T04:47:44.127Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2025-22367" }, { "tags": [ "vendor-advisory" ], "url": "https://csirt.divd.nl/DIVD-2025-00003" }, { "tags": [ "release-notes" ], "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf" } ], "source": { "discovery": "EXTERNAL" }, "title": "Mennekes smart/premium charges systems, Command injection in time setting", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2025-22367", "datePublished": "2025-03-11T13:40:21.388Z", "dateReserved": "2025-01-03T14:56:05.686Z", "dateUpdated": "2025-04-01T04:47:44.127Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-22370 (GCVE-0-2025-22370)
Vulnerability from cvelistv5
Published
2025-03-11 13:40
Modified
2025-04-01 04:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
- OWASP-A03
Summary
Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.
References
▼ | URL | Tags |
---|---|---|
https://csirt.divd.nl/CVE-2025-22370 | third-party-advisory | |
https://csirt.divd.nl/DIVD-2025-00003 | vendor-advisory | |
https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf | release-notes |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Mennekes | Smart / Premium charging stations |
Version: * ≤ |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-22370", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-11T15:03:05.010221Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-11T15:03:11.787Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Smart / Premium charging stations", "vendor": "Mennekes", "versions": [ { "lessThan": "2.15", "status": "affected", "version": "*", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Wilco van Beijnum" }, { "lang": "en", "type": "analyst", "value": "Harm van den Brink(DIVD)" }, { "lang": "en", "type": "analyst", "value": "Frank Breedijk (DIVD)" } ], "datePublic": "2025-03-10T14:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e" } ], "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized." } ], "impacts": [ { "capecId": "CAPEC-66", "descriptions": [ { "lang": "en", "value": "CAPEC-66 SQL Injection" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "YES", "Recovery": "NOT_DEFINED", "Safety": "NEGLIGIBLE", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 5.3, "baseSeverity": "MEDIUM", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "LOW", "vulnIntegrityImpact": "LOW", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-89", "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "description": "OWASP-A03", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2025-04-01T04:47:46.281Z", "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "shortName": "DIVD" }, "references": [ { "tags": [ "third-party-advisory" ], "url": "https://csirt.divd.nl/CVE-2025-22370" }, { "tags": [ "vendor-advisory" ], "url": "https://csirt.divd.nl/DIVD-2025-00003" }, { "tags": [ "release-notes" ], "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf" } ], "source": { "discovery": "EXTERNAL" }, "title": "Mennekes smart/premium charges systems, SQL Injection in web configuration interface", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217", "assignerShortName": "DIVD", "cveId": "CVE-2025-22370", "datePublished": "2025-03-11T13:40:22.946Z", "dateReserved": "2025-01-03T14:56:05.686Z", "dateUpdated": "2025-04-01T04:47:46.281Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }