Vulnerabilites related to Mennekes - Smart / Premium charging stations
CVE-2025-22368 (GCVE-0-2025-22368)
Vulnerability from cvelistv5
Published
2025-03-11 13:40
Modified
2025-04-01 04:47
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • CWE-250
  • OWASP-A03
Summary
The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22368",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-11T15:03:42.139099Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-11T15:03:48.901Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Smart / Premium charging stations",
          "vendor": "Mennekes",
          "versions": [
            {
              "lessThan": "2.15",
              "status": "affected",
              "version": "*",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Wilco van Beijnum"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Harm van den Brink(DIVD)"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Frank Breedijk (DIVD)"
        }
      ],
      "datePublic": "2025-03-10T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248 Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "NOT_DEFINED",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-250",
              "description": "CWE-250",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "description": "OWASP-A03",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-01T04:47:45.140Z",
        "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "shortName": "DIVD"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://csirt.divd.nl/CVE-2025-22368"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://csirt.divd.nl/DIVD-2025-00003"
        },
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Mennekes smart/premium charges systems, Command injection in sCU firmware update",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
    "assignerShortName": "DIVD",
    "cveId": "CVE-2025-22368",
    "datePublished": "2025-03-11T13:40:22.216Z",
    "dateReserved": "2025-01-03T14:56:05.686Z",
    "dateUpdated": "2025-04-01T04:47:45.140Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-22369 (GCVE-0-2025-22369)
Vulnerability from cvelistv5
Published
2025-03-11 13:40
Modified
2025-04-01 04:47
CWE
  • CWE-552 - Files or Directories Accessible to External Parties
Summary
The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22369",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-11T14:52:14.627801Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-11T14:52:22.813Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Smart / Premium charging stations",
          "vendor": "Mennekes",
          "versions": [
            {
              "lessThan": "2.15",
              "status": "affected",
              "version": "*",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Wilco van Beijnum"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Harm van den Brink(DIVD)"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Frank Breedijk (DIVD)"
        }
      ],
      "datePublic": "2025-03-10T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-597",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-597 Absolute Path Traversal"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "NOT_DEFINED",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-552",
              "description": "CWE-552 Files or Directories Accessible to External Parties",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-01T04:47:47.988Z",
        "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "shortName": "DIVD"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://csirt.divd.nl/CVE-2025-22369"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://csirt.divd.nl/DIVD-2025-00003"
        },
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Mennekes smart/premium charges systems, Arbitrary file download using ReadFile endpoint",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
    "assignerShortName": "DIVD",
    "cveId": "CVE-2025-22369",
    "datePublished": "2025-03-11T13:40:24.403Z",
    "dateReserved": "2025-01-03T14:56:05.686Z",
    "dateUpdated": "2025-04-01T04:47:47.988Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-22366 (GCVE-0-2025-22366)
Vulnerability from cvelistv5
Published
2025-03-11 13:40
Modified
2025-04-01 04:47
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • CWE-250
  • OWASP-A03
Summary
The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22366",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-11T14:53:28.425309Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-11T14:53:56.159Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Smart / Premium charging stations",
          "vendor": "Mennekes",
          "versions": [
            {
              "lessThan": "2.15",
              "status": "affected",
              "version": "*",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Wilco van Beijnum"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Harm van den Brink(DIVD)"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Frank Breedijk (DIVD)"
        }
      ],
      "datePublic": "2025-03-10T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248 Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "NOT_DEFINED",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-250",
              "description": "CWE-250",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "description": "OWASP-A03",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-01T04:47:47.110Z",
        "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "shortName": "DIVD"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://csirt.divd.nl/CVE-2025-22366"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://csirt.divd.nl/DIVD-2025-00003"
        },
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Mennekes smart/premium charges systems, Command injection in firmware upgrade",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
    "assignerShortName": "DIVD",
    "cveId": "CVE-2025-22366",
    "datePublished": "2025-03-11T13:40:23.659Z",
    "dateReserved": "2025-01-03T14:56:05.685Z",
    "dateUpdated": "2025-04-01T04:47:47.110Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-22367 (GCVE-0-2025-22367)
Vulnerability from cvelistv5
Published
2025-03-11 13:40
Modified
2025-04-01 04:47
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • CWE-250
  • OWASP-A03
Summary
The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22367",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-11T19:23:05.314995Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-11T19:23:24.531Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Smart / Premium charging stations",
          "vendor": "Mennekes",
          "versions": [
            {
              "lessThan": "2.15",
              "status": "affected",
              "version": "*",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Wilco van Beijnum"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Harm van den Brink(DIVD)"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Frank Breedijk (DIVD)"
        }
      ],
      "datePublic": "2025-03-10T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248 Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "NOT_DEFINED",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:N/SA:N/S:N/AU:Y",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-250",
              "description": "CWE-250",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "description": "OWASP-A03",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-01T04:47:44.127Z",
        "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "shortName": "DIVD"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://csirt.divd.nl/CVE-2025-22367"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://csirt.divd.nl/DIVD-2025-00003"
        },
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Mennekes smart/premium charges systems, Command injection in time setting",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
    "assignerShortName": "DIVD",
    "cveId": "CVE-2025-22367",
    "datePublished": "2025-03-11T13:40:21.388Z",
    "dateReserved": "2025-01-03T14:56:05.686Z",
    "dateUpdated": "2025-04-01T04:47:44.127Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-22370 (GCVE-0-2025-22370)
Vulnerability from cvelistv5
Published
2025-03-11 13:40
Modified
2025-04-01 04:47
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
  • OWASP-A03
Summary
Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22370",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-11T15:03:05.010221Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-11T15:03:11.787Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Smart / Premium charging stations",
          "vendor": "Mennekes",
          "versions": [
            {
              "lessThan": "2.15",
              "status": "affected",
              "version": "*",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Wilco van Beijnum"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Harm van den Brink(DIVD)"
        },
        {
          "lang": "en",
          "type": "analyst",
          "value": "Frank Breedijk (DIVD)"
        }
      ],
      "datePublic": "2025-03-10T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Many fields for the web configuration interface of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to execute arbitrary SQL commands because the values are insufficiently neutralized."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-66",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-66 SQL Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "YES",
            "Recovery": "NOT_DEFINED",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/S:N/AU:Y",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "description": "OWASP-A03",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-01T04:47:46.281Z",
        "orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
        "shortName": "DIVD"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://csirt.divd.nl/CVE-2025-22370"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://csirt.divd.nl/DIVD-2025-00003"
        },
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://www.mennekes.nl/fileadmin/MEN-Deutschland/emobility/04_software/06_smart_premium/Release_Notes_for_2.15_06.03.2025.pdf"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Mennekes smart/premium charges systems, SQL Injection in web configuration interface",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
    "assignerShortName": "DIVD",
    "cveId": "CVE-2025-22370",
    "datePublished": "2025-03-11T13:40:22.946Z",
    "dateReserved": "2025-01-03T14:56:05.686Z",
    "dateUpdated": "2025-04-01T04:47:46.281Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}