Common Weakness Enumeration

CWE-284

Discouraged

Improper Access Control

Abstraction: Pillar · Status: Incomplete

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

7803 vulnerabilities reference this CWE, most recent first.

CVE-2022-26389 (GCVE-0-2022-26389)

Vulnerability from cvelistv5 – Published: 2025-02-07 17:07 – Updated: 2025-02-07 18:49
VLAI
Title
Improper Access Control Vulnerability in ELI Electrocardiograph Devices
Summary
An improper access control vulnerability may allow privilege escalation.This issue affects:  * ELI 380 Resting Electrocardiograph: Versions 2.6.0 and prior;  * ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: Versions 2.3.1 and prior;  * ELI 250c/BUR 250c Resting Electrocardiograph: Versions 2.1.2 and prior;  * ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: Versions 2.2.0 and prior.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-284 - Improper Access Control
Assigner
Credits
An anonymous user reported these vulnerabilities to Hillrom.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26389",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-07T18:49:13.343999Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-07T18:49:22.506Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ELI 380 Resting  Electrocardiograph",
          "vendor": "Baxter/ Hillrom",
          "versions": [
            {
              "lessThanOrEqual": "2.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph",
          "vendor": "Welch Allyn",
          "versions": [
            {
              "lessThanOrEqual": "2.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ELI 250c/BUR 250c Resting Electrocardiograph",
          "vendor": "Welch Allyn",
          "versions": [
            {
              "lessThanOrEqual": "2.1.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph",
          "vendor": "Welch Allyn",
          "versions": [
            {
              "lessThanOrEqual": "2.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "An anonymous user reported these vulnerabilities to Hillrom."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An improper access control vulnerability may allow privilege escalation.\u003cp\u003eThis issue affects:\u0026nbsp;\u003c/p\u003e\u003cul\u003e\u003cli\u003eELI 380 Resting Electrocardiograph:\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVersions 2.6.0 and prior;\u003c/span\u003e\u0026nbsp;\u003c/li\u003e\u003cli\u003eELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVersions 2.3.1 and prior\u003c/span\u003e;\u0026nbsp;\u003c/li\u003e\u003cli\u003eELI 250c/BUR 250c Resting Electrocardiograph:\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVersions 2.1.2 and prior;\u0026nbsp;\u003c/span\u003e\u003c/li\u003e\u003cli\u003eELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVersions 2.2.0 and prior\u003c/span\u003e.\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "An improper access control vulnerability may allow privilege escalation.This issue affects:\u00a0\n\n  *  ELI 380 Resting Electrocardiograph:\n\nVersions 2.6.0 and prior;\u00a0\n  *  ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:\n\nVersions 2.3.1 and prior;\u00a0\n  *  ELI 250c/BUR 250c Resting Electrocardiograph:\u00a0Versions 2.1.2 and prior;\u00a0\n  *  ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: \n\nVersions 2.2.0 and prior."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-07T17:07:27.929Z",
        "orgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
        "shortName": "Baxter"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-167-01"
        },
        {
          "url": "https://hillrom.com/en/responsible-disclosures/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eHillrom has released software updates for all impacted devices to \naddress these vulnerabilities. New product versions that mitigate these \nvulnerabilities are available as follows:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003eWelch Allyn ELI 380 Resting Electrocardiograph: available Q4 2023\u003c/li\u003e\n\u003cli\u003eWelch Allyn ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: available May 2022\u003c/li\u003e\n\u003cli\u003eWelch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: available Q4 2023\u003c/li\u003e\n\u003c/ul\u003e\n\u003cp\u003eHillrom recommends users upgrade to the latest product versions. \nInformation on how to update these products can be found on the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://hillrom.com/en/responsible-disclosures/\"\u003eHillrom disclosure page\u003c/a\u003e\u003c/p\u003e.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Hillrom has released software updates for all impacted devices to \naddress these vulnerabilities. New product versions that mitigate these \nvulnerabilities are available as follows:\n\n\n\n  *  Welch Allyn ELI 380 Resting Electrocardiograph: available Q4 2023\n\n  *  Welch Allyn ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph: available May 2022\n\n  *  Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: available Q4 2023\n\n\n\n\nHillrom recommends users upgrade to the latest product versions. \nInformation on how to update these products can be found on the  Hillrom disclosure page https://hillrom.com/en/responsible-disclosures/ \n\n."
        }
      ],
      "source": {
        "advisory": "ICSMA-22-167-01",
        "discovery": "EXTERNAL"
      },
      "title": "Improper Access Control Vulnerability in ELI Electrocardiograph Devices",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eHillrom recommends the following workarounds to help reduce risk:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003eApply proper network and physical security controls.\u003c/li\u003e\n\u003cli\u003eEnsure a unique encryption key is configured for ELI Link and Cardiograph.\u003c/li\u003e\n\u003cli\u003eWhere possible, use a firewall to prevent communication on Port 21 \nFTP service, Port 22 SSH (Secure Shell Connection), and Port 23 Telnet \nservice.\u003c/li\u003e\n\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Hillrom recommends the following workarounds to help reduce risk:\n\n\n\n  *  Apply proper network and physical security controls.\n\n  *  Ensure a unique encryption key is configured for ELI Link and Cardiograph.\n\n  *  Where possible, use a firewall to prevent communication on Port 21 \nFTP service, Port 22 SSH (Secure Shell Connection), and Port 23 Telnet \nservice."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dba971b9-eb30-4121-91e1-3b45611354aa",
    "assignerShortName": "Baxter",
    "cveId": "CVE-2022-26389",
    "datePublished": "2025-02-07T17:07:27.929Z",
    "dateReserved": "2022-03-03T22:04:24.534Z",
    "dateUpdated": "2025-02-07T18:49:22.506Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26346 (GCVE-0-2022-26346)

Vulnerability from cvelistv5 – Published: 2022-08-05 21:18 – Updated: 2025-04-15 18:54
VLAI
Summary
A denial of service vulnerability exists in the ucloud_del_node functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted network packet can lead to denial of service. An attacker can send packets to trigger this vulnerability.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
TCL LinkHub Mesh Wifi Affected: MS1G_00_01.00_14
Create a notification for this product.
Date Public
2022-08-01 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.881Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1507"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-26346",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T18:18:55.519475Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T18:54:01.879Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LinkHub Mesh Wifi",
          "vendor": "TCL",
          "versions": [
            {
              "status": "affected",
              "version": "MS1G_00_01.00_14"
            }
          ]
        }
      ],
      "datePublic": "2022-08-01T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A denial of service vulnerability exists in the ucloud_del_node functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted network packet can lead to denial of service. An attacker can send packets to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-05T21:18:33.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1507"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "DATE_PUBLIC": "2022-08-01",
          "ID": "CVE-2022-26346",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LinkHub Mesh Wifi",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "MS1G_00_01.00_14"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "TCL"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A denial of service vulnerability exists in the ucloud_del_node functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. A specially-crafted network packet can lead to denial of service. An attacker can send packets to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.6,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1507",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1507"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-26346",
    "datePublished": "2022-08-05T21:18:33.440Z",
    "dateReserved": "2022-03-23T00:00:00.000Z",
    "dateUpdated": "2025-04-15T18:54:01.879Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26317 (GCVE-0-2022-26317)

Vulnerability from cvelistv5 – Published: 2022-03-08 11:31 – Updated: 2024-08-03 05:03
VLAI
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.29). When returning the result of a completed Microflow execution call the affected framework does not correctly verify, if the request was initially made by the user requesting the result. Together with predictable identifiers for Microflow execution calls, this could allow a malicious attacker to retrieve information about arbitrary Microflow execution calls made by users within the affected system.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Siemens Mendix Applications using Mendix 7 Affected: All versions < V7.23.29
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.443Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Applications using Mendix 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.23.29"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.29). When returning the result of a completed Microflow execution call the affected framework does not correctly verify, if the request was initially made by the user requesting the result. Together with predictable identifiers for Microflow execution calls, this could allow a malicious attacker to retrieve information about arbitrary Microflow execution calls made by users within the affected system."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-08T11:31:37.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-26317",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Applications using Mendix 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.23.29"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.29). When returning the result of a completed Microflow execution call the affected framework does not correctly verify, if the request was initially made by the user requesting the result. Together with predictable identifiers for Microflow execution calls, this could allow a malicious attacker to retrieve information about arbitrary Microflow execution calls made by users within the affected system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-415938.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-26317",
    "datePublished": "2022-03-08T11:31:37.000Z",
    "dateReserved": "2022-02-28T00:00:00.000Z",
    "dateUpdated": "2024-08-03T05:03:32.443Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26313 (GCVE-0-2022-26313)

Vulnerability from cvelistv5 – Published: 2022-03-08 11:31 – Updated: 2024-08-03 05:03
VLAI
Summary
A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions >= V3.3.0 < V3.5.1). In certain configurations of the affected product, a threat actor could use the sign up flow to hijack arbitrary user accounts.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Siemens Mendix Forgot Password Appstore module Affected: All versions >= V3.3.0 < V3.5.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:31.844Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-134279.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mendix Forgot Password Appstore module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.3.0 \u003c V3.5.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions \u003e= V3.3.0 \u003c V3.5.1). In certain configurations of the affected product, a threat actor could use the sign up flow to hijack arbitrary user accounts."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-08T11:31:34.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-134279.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-26313",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mendix Forgot Password Appstore module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V3.3.0 \u003c V3.5.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions \u003e= V3.3.0 \u003c V3.5.1). In certain configurations of the affected product, a threat actor could use the sign up flow to hijack arbitrary user accounts."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-134279.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-134279.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-26313",
    "datePublished": "2022-03-08T11:31:34.000Z",
    "dateReserved": "2022-02-28T00:00:00.000Z",
    "dateUpdated": "2024-08-03T05:03:31.844Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26308 (GCVE-0-2022-26308)

Vulnerability from cvelistv5 – Published: 2022-08-01 12:44 – Updated: 2024-09-17 02:31
VLAI
Title
Improper Access Control in Configuration (Credential store)
Summary
Pandora FMS v7.0NG.760 and below allows an improper access control in Configuration (Credential store) where a user with the role of Operator (Write) could create, delete, view existing keys which are outside the intended role.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Artica PFMS Pandora FMS Affected: v760 , ≤ v760 (custom)
Create a notification for this product.
Date Public
2022-05-13 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:31.844Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://pandorafms.com/en/security/common-vulnerabilities-and-exposures/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.incibe.es/en/cve-assignment-publication/coordinated-cves"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "all"
          ],
          "product": "Pandora FMS",
          "vendor": "Artica PFMS",
          "versions": [
            {
              "lessThanOrEqual": "v760",
              "status": "affected",
              "version": "v760",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-05-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Pandora FMS v7.0NG.760 and below allows an improper access control in Configuration (Credential store) where a user with the role of Operator (Write) could create, delete, view existing keys which are outside the intended role."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-01T12:44:04.000Z",
        "orgId": "63375d6c-d89a-45ed-8ecc-c8c361b0e04c",
        "shortName": "ARTICA"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://pandorafms.com/en/security/common-vulnerabilities-and-exposures/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.incibe.es/en/cve-assignment-publication/coordinated-cves"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Fixed in v761"
        }
      ],
      "source": {
        "defect": [
          "4844"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Improper Access Control in Configuration (Credential store)",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@pandorafms.com",
          "DATE_PUBLIC": "2022-05-13T08:00:00.000Z",
          "ID": "CVE-2022-26308",
          "STATE": "PUBLIC",
          "TITLE": "Improper Access Control in Configuration (Credential store)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Pandora FMS",
                      "version": {
                        "version_data": [
                          {
                            "platform": "all",
                            "version_affected": "\u003c=",
                            "version_name": "v760",
                            "version_value": "v760"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Artica PFMS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Pandora FMS v7.0NG.760 and below allows an improper access control in Configuration (Credential store) where a user with the role of Operator (Write) could create, delete, view existing keys which are outside the intended role."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://pandorafms.com/en/security/common-vulnerabilities-and-exposures/",
              "refsource": "CONFIRM",
              "url": "https://pandorafms.com/en/security/common-vulnerabilities-and-exposures/"
            },
            {
              "name": "https://www.incibe.es/en/cve-assignment-publication/coordinated-cves",
              "refsource": "CONFIRM",
              "url": "https://www.incibe.es/en/cve-assignment-publication/coordinated-cves"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Fixed in v761"
          }
        ],
        "source": {
          "defect": [
            "4844"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "63375d6c-d89a-45ed-8ecc-c8c361b0e04c",
    "assignerShortName": "ARTICA",
    "cveId": "CVE-2022-26308",
    "datePublished": "2022-08-01T12:44:04.444Z",
    "dateReserved": "2022-02-28T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:31:29.597Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26091 (GCVE-0-2022-26091)

Vulnerability from cvelistv5 – Published: 2022-04-11 19:37 – Updated: 2024-08-03 04:56
VLAI
Summary
Improper access control vulnerability in Knox Manage prior to SMR Apr-2022 Release 1 allows that physical attackers can bypass Knox Manage using a function key of hardware keyboard.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Samsung Mobile Samsung Mobile Devices Affected: Q(10), R(11), S(12) , < SMR Apr-2022 Release 1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:56:37.781Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=4"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Samsung Mobile Devices",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "SMR Apr-2022 Release 1",
              "status": "affected",
              "version": "Q(10), R(11), S(12)",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper access control vulnerability in Knox Manage prior to SMR Apr-2022 Release 1 allows that physical attackers can bypass Knox Manage using a function key of hardware keyboard."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-11T19:37:01.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=4"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2022-26091",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Samsung Mobile Devices",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Q(10), R(11), S(12)",
                            "version_value": "SMR Apr-2022 Release 1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper access control vulnerability in Knox Manage prior to SMR Apr-2022 Release 1 allows that physical attackers can bypass Knox Manage using a function key of hardware keyboard."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=4",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=4"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2022-26091",
    "datePublished": "2022-04-11T19:37:01.000Z",
    "dateReserved": "2022-02-24T00:00:00.000Z",
    "dateUpdated": "2024-08-03T04:56:37.781Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25932 (GCVE-0-2022-25932)

Vulnerability from cvelistv5 – Published: 2022-11-09 17:35 – Updated: 2025-04-15 18:41
VLAI
Summary
The firmware of InHand Networks InRouter302 V3.5.45 introduces fixes for TALOS-2022-1472 and TALOS-2022-1474. The fixes are incomplete. An attacker can still perform, respectively, a privilege escalation and an information disclosure vulnerability.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-284 - Improper Access Control
Assigner
Impacted products
Date Public
2022-10-27 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:44.462Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1523"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://inhandnetworks.com/upload/attachment/202210/25/InHand-PSA-2022-02.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-25932",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T18:12:42.558681Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T18:41:18.033Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "InRouter302",
          "vendor": "InHand Networks",
          "versions": [
            {
              "status": "affected",
              "version": "V3.5.45"
            }
          ]
        }
      ],
      "datePublic": "2022-10-27T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The firmware of InHand Networks InRouter302 V3.5.45 introduces fixes for TALOS-2022-1472 and TALOS-2022-1474. The fixes are incomplete. An attacker can still perform, respectively, a privilege escalation and an information disclosure vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-09T00:00:00.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1523"
        },
        {
          "url": "https://inhandnetworks.com/upload/attachment/202210/25/InHand-PSA-2022-02.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-25932",
    "datePublished": "2022-11-09T17:35:34.920Z",
    "dateReserved": "2022-05-16T00:00:00.000Z",
    "dateUpdated": "2025-04-15T18:41:18.033Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25831 (GCVE-0-2022-25831)

Vulnerability from cvelistv5 – Published: 2022-04-11 19:36 – Updated: 2024-08-03 04:49
VLAI
Summary
Improper access control vulnerability in S Secure prior to SMR Apr-2022 Release 1 allows physical attackers to access secured data in certain conditions.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Samsung Mobile Samsung Mobile Devices Affected: Select Q(10), R(11), S(12) devices , < SMR Apr-2022 Release 1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.766Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=4"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Samsung Mobile Devices",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "SMR Apr-2022 Release 1",
              "status": "affected",
              "version": "Select Q(10), R(11), S(12) devices",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper access control vulnerability in S Secure prior to SMR Apr-2022 Release 1 allows physical attackers to access secured data in certain conditions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "NONE",
            "baseScore": 2,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-11T19:36:57.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=4"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2022-25831",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Samsung Mobile Devices",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Select Q(10), R(11), S(12) devices",
                            "version_value": "SMR Apr-2022 Release 1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper access control vulnerability in S Secure prior to SMR Apr-2022 Release 1 allows physical attackers to access secured data in certain conditions."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "NONE",
            "baseScore": 2,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=4",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=4"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2022-25831",
    "datePublished": "2022-04-11T19:36:57.000Z",
    "dateReserved": "2022-02-23T00:00:00.000Z",
    "dateUpdated": "2024-08-03T04:49:43.766Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25824 (GCVE-0-2022-25824)

Vulnerability from cvelistv5 – Published: 2022-03-08 13:47 – Updated: 2024-08-03 04:49
VLAI
Summary
Improper access control vulnerability in BixbyTouch prior to version 2.2.00.6 in China models allows untrusted applications to load arbitrary URL and local files in webview.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Samsung Mobile BixbyTouch Affected: - , < 2.2.00.6 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.776Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2022\u0026month=3"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BixbyTouch",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "2.2.00.6",
              "status": "affected",
              "version": "-",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper access control vulnerability in BixbyTouch prior to version 2.2.00.6 in China models allows untrusted applications to load arbitrary URL and local files in webview."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-08T13:47:40.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2022\u0026month=3"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2022-25824",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BixbyTouch",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "-",
                            "version_value": "2.2.00.6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper access control vulnerability in BixbyTouch prior to version 2.2.00.6 in China models allows untrusted applications to load arbitrary URL and local files in webview."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/serviceWeb.smsb?year=2022\u0026month=3",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2022\u0026month=3"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2022-25824",
    "datePublished": "2022-03-08T13:47:40.000Z",
    "dateReserved": "2022-02-23T00:00:00.000Z",
    "dateUpdated": "2024-08-03T04:49:43.776Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25755 (GCVE-0-2022-25755)

Vulnerability from cvelistv5 – Published: 2022-04-12 09:07 – Updated: 2024-08-03 04:49
VLAI
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Siemens SCALANCE X302-7 EEC (230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X304-2FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X306-1LD FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-3 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-3LD Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LD Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LH Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LH+ Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M PoE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M TS Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X310 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X310FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X320-1 FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X320-1-2LD FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X408-2 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (230V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (230V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M TS (24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (230V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (230V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SIPLUS NET SCALANCE X308-2 Affected: All versions < V4.1.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.216Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:50.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-25755",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-25755",
    "datePublished": "2022-04-12T09:07:50.000Z",
    "dateReserved": "2022-02-22T00:00:00.000Z",
    "dateUpdated": "2024-08-03T04:49:43.216Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation MIT-1
Architecture and Design Operation

Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.

Mitigation MIT-46
Architecture and Design

Strategy: Separation of Privilege

  • Compartmentalize the system to have "safe" areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area.
  • Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
CAPEC-19: Embedding Scripts within Scripts

An adversary leverages the capability to execute their own script by embedding it within other scripts that the target software is likely to execute due to programs' vulnerabilities that are brought on by allowing remote hosts to execute scripts.

CAPEC-441: Malicious Logic Insertion

An adversary installs or adds malicious logic (also known as malware) into a seemingly benign component of a fielded system. This logic is often hidden from the user of the system and works behind the scenes to achieve negative impacts. With the proliferation of mass digital storage and inexpensive multimedia devices, Bluetooth and 802.11 support, new attack vectors for spreading malware are emerging for things we once thought of as innocuous greeting cards, picture frames, or digital projectors. This pattern of attack focuses on systems already fielded and used in operation as opposed to systems and their components that are still under development and part of the supply chain.

CAPEC-478: Modification of Windows Service Configuration

An adversary exploits a weakness in access control to modify the execution parameters of a Windows service. The goal of this attack is to execute a malicious binary in place of an existing service.

CAPEC-479: Malicious Root Certificate

An adversary exploits a weakness in authorization and installs a new root certificate on a compromised system. Certificates are commonly used for establishing secure TLS/SSL communications within a web browser. When a user attempts to browse a website that presents a certificate that is not trusted an error message will be displayed to warn the user of the security risk. Depending on the security settings, the browser may not allow the user to establish a connection to the website. Adversaries have used this technique to avoid security warnings prompting users when compromised systems connect over HTTPS to adversary controlled web servers that spoof legitimate websites in order to collect login credentials.

CAPEC-502: Intent Spoof

An adversary, through a previously installed malicious application, issues an intent directed toward a specific trusted application's component in an attempt to achieve a variety of different objectives including modification of data, information disclosure, and data injection. Components that have been unintentionally exported and made public are subject to this type of an attack. If the component trusts the intent's action without verififcation, then the target application performs the functionality at the adversary's request, helping the adversary achieve the desired negative technical impact.

CAPEC-503: WebView Exposure

An adversary, through a malicious web page, accesses application specific functionality by leveraging interfaces registered through WebView's addJavascriptInterface API. Once an interface is registered to WebView through addJavascriptInterface, it becomes global and all pages loaded in the WebView can call this interface.

CAPEC-536: Data Injected During Configuration

An attacker with access to data files and processes on a victim's system injects malicious data into critical operational data during configuration or recalibration, causing the victim's system to perform in a suboptimal manner that benefits the adversary.

CAPEC-546: Incomplete Data Deletion in a Multi-Tenant Environment

An adversary obtains unauthorized information due to insecure or incomplete data deletion in a multi-tenant environment. If a cloud provider fails to completely delete storage and data from former cloud tenants' systems/resources, once these resources are allocated to new, potentially malicious tenants, the latter can probe the provided resources for sensitive information still there.

CAPEC-550: Install New Service

When an operating system starts, it also starts programs called services or daemons. Adversaries may install a new service which will be executed at startup (on a Windows system, by modifying the registry). The service name may be disguised by using a name from a related operating system or benign software. Services are usually run with elevated privileges.

CAPEC-551: Modify Existing Service

When an operating system starts, it also starts programs called services or daemons. Modifying existing services may break existing services or may enable services that are disabled/not commonly used.

CAPEC-552: Install Rootkit

An adversary exploits a weakness in authentication to install malware that alters the functionality and information provide by targeted operating system API calls. Often referred to as rootkits, it is often used to hide the presence of programs, files, network connections, services, drivers, and other system components.

CAPEC-556: Replace File Extension Handlers

When a file is opened, its file handler is checked to determine which program opens the file. File handlers are configuration properties of many operating systems. Applications can modify the file handler for a given file extension to call an arbitrary program when a file with the given extension is opened.

CAPEC-558: Replace Trusted Executable

An adversary exploits weaknesses in privilege management or access control to replace a trusted executable with a malicious version and enable the execution of malware when that trusted executable is called.

CAPEC-562: Modify Shared File

An adversary manipulates the files in a shared location by adding malicious programs, scripts, or exploit code to valid content. Once a user opens the shared content, the tainted content is executed.

CAPEC-563: Add Malicious File to Shared Webroot

An adversaries may add malicious content to a website through the open file share and then browse to that content with a web browser to cause the server to execute the content. The malicious content will typically run under the context and permissions of the web server process, often resulting in local system or administrative privileges depending on how the web server is configured.

CAPEC-564: Run Software at Logon

Operating system allows logon scripts to be run whenever a specific user or users logon to a system. If adversaries can access these scripts, they may insert additional code into the logon script. This code can allow them to maintain persistence or move laterally within an enclave because it is executed every time the affected user or users logon to a computer. Modifying logon scripts can effectively bypass workstation and enclave firewalls. Depending on the access configuration of the logon scripts, either local credentials or a remote administrative account may be necessary.

CAPEC-578: Disable Security Software

An adversary exploits a weakness in access control to disable security tools so that detection does not occur. This can take the form of killing processes, deleting registry keys so that tools do not start at run time, deleting log files, or other methods.