var-202402-1997
Vulnerability from variot

An issue was discovered in gui/util/qktxhandler.cpp in Qt before 5.15.17, 6.x before 6.2.12, 6.3.x through 6.5.x before 6.5.5, and 6.6.x before 6.6.2. A buffer overflow and application crash can occur via a crafted KTX image file. Tenda AC18 is a router made by the Chinese company Tenda.

There is a buffer overflow vulnerability in Tenda AC18 V15.03.05.05. The vulnerability is caused by the cmdinput parameter of the formexeCommand function in the /goform/execCommand file failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute on the system. Arbitrary code or lead to denial of service attacks. DescriptionA flaw was found in Qt Base. This flaw allows an malicious user to use a specially crafted KTX image file to trigger a buffer overflow in the application reading it, leading to a denial of service.A flaw was found in Qt Base

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202402-1997",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "15.03.05.05"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ]
  },
  "cve": "CVE-2024-25580",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-14308",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "HIGH",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.5,
            "id": "CVE-2024-25580",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-25580",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-14308",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered in gui/util/qktxhandler.cpp in Qt before 5.15.17, 6.x before 6.2.12, 6.3.x through 6.5.x before 6.5.5, and 6.6.x before 6.6.2. A buffer overflow and application crash can occur via a crafted KTX image file. Tenda AC18 is a router made by the Chinese company Tenda. \n\r\n\r\nThere is a buffer overflow vulnerability in Tenda AC18 V15.03.05.05. The vulnerability is caused by the cmdinput parameter of the formexeCommand function in the /goform/execCommand file failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute on the system. Arbitrary code or lead to denial of service attacks. Description\u003c!----\u003eA flaw was found in Qt Base. This flaw allows an malicious user to use a specially crafted KTX image file to trigger a buffer overflow in the application reading it, leading to a denial of service.A flaw was found in Qt Base",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      }
    ],
    "trust": 1.53
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-25580",
        "trust": 1.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "id": "VAR-202402-1997",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ]
  },
  "last_update_date": "2024-10-30T23:19:58.117000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC18 formexeCommand function buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/534891"
      },
      {
        "title": "Debian CVElist Bug Report Logs: qt6-base: CVE-2024-25580",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=debian_cvelist_bugreportlogs\u0026qid=2ebf1524fcece0a7b0c6937e8d2445fe"
      },
      {
        "title": "Red Hat: ",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=red_hat_cve_database\u0026qid=CVE-2024-25580"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "https://www.qt.io/blog/security-advisory-potential-buffer-overflow-when-reading-ktx-images"
      },
      {
        "trust": 0.7,
        "url": "https://access.redhat.com/security/cve/cve-2024-25580"
      },
      {
        "trust": 0.1,
        "url": "https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=1064052"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "date": "2024-03-27T03:15:12.007000",
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "date": "2024-10-29T20:35:17.633000",
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 formexeCommand function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.