var-202207-0555
Vulnerability from variot
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions. Siemens SCALANCE X Switches is an industrial Ethernet switch product from Siemens (Siemens) in Germany
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202207-0555", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance x204-2fm", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ld ts", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204-2ts", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x206-1ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x212-2ld", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf204", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf204-2", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf206-1", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf208", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x200-4p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x201-3p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x201-3p irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x204irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x204irt pro", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance xf204irt", "scope": null, "trust": 1.2, "vendor": "siemens", "version": null }, { "model": "scalance x202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x206-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x200-4p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204-2ba irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x208 pro", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x212-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204-2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x208", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x204irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x204irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x224", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance x216", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance xf202-2p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x202-2p irt pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x201-3p irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf204irt", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x204-2\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x206-1\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x208\u003c5.2.6" }, { "model": "scalance x208pro", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x212-2\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x216\u003c5.2.6" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x224\u003c5.2.6" }, { "model": "scalance xf201-3p irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf202-2p irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "scalance xf204-2ba irt", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "NVD", "id": "CVE-2022-26647" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-950" } ], "trust": 0.6 }, "cve": "CVE-2022-26647", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2022-26647", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2022-51440", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-26647", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2022-26647", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-26647", "trust": 1.0, "value": "CRITICAL" }, { "author": "productcert@siemens.com", "id": "CVE-2022-26647", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2022-51440", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202207-950", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2022-26647", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "VULMON", "id": "CVE-2022-26647" }, { "db": "CNNVD", "id": "CNNVD-202207-950" }, { "db": "NVD", "id": "CVE-2022-26647" }, { "db": "NVD", "id": "CVE-2022-26647" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204-2 (All versions \u003c V5.2.6), SCALANCE X204-2FM (All versions \u003c V5.2.6), SCALANCE X204-2LD (All versions \u003c V5.2.6), SCALANCE X204-2LD TS (All versions \u003c V5.2.6), SCALANCE X204-2TS (All versions \u003c V5.2.6), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE X206-1 (All versions \u003c V5.2.6), SCALANCE X206-1LD (All versions \u003c V5.2.6), SCALANCE X208 (All versions \u003c V5.2.6), SCALANCE X208PRO (All versions \u003c V5.2.6), SCALANCE X212-2 (All versions \u003c V5.2.6), SCALANCE X212-2LD (All versions \u003c V5.2.6), SCALANCE X216 (All versions \u003c V5.2.6), SCALANCE X224 (All versions \u003c V5.2.6), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204 (All versions \u003c V5.2.6), SCALANCE XF204-2 (All versions \u003c V5.2.6), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SCALANCE XF206-1 (All versions \u003c V5.2.6), SCALANCE XF208 (All versions \u003c V5.2.6). The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions. Siemens SCALANCE X Switches is an industrial Ethernet switch product from Siemens (Siemens) in Germany", "sources": [ { "db": "NVD", "id": "CVE-2022-26647" }, { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "VULMON", "id": "CVE-2022-26647" } ], "trust": 1.53 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-26647", "trust": 2.3 }, { "db": "SIEMENS", "id": "SSA-310038", "trust": 2.3 }, { "db": "ICS CERT", "id": "ICSA-22-195-01", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2022-51440", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022071408", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202207-950", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-26647", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "VULMON", "id": "CVE-2022-26647" }, { "db": "CNNVD", "id": "CNNVD-202207-950" }, { "db": "NVD", "id": "CVE-2022-26647" } ] }, "id": "VAR-202207-0555", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" } ], "trust": 1.1104343616666665 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" } ] }, "last_update_date": "2024-08-14T13:42:37.019000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Unknown Vulnerability in Siemens SCALANCE X Switches", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/339406" }, { "title": "Siemens SCALANCE Security Feature Issues Feature Issues Vulnerabilities Repair Measures", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=232914" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "CNNVD", "id": "CNNVD-202207-950" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-330", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-26647" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdf" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-310038.html" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-26647/" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022071408" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-195-01" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/330.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-195-01" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "VULMON", "id": "CVE-2022-26647" }, { "db": "CNNVD", "id": "CNNVD-202207-950" }, { "db": "NVD", "id": "CVE-2022-26647" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-51440" }, { "db": "VULMON", "id": "CVE-2022-26647" }, { "db": "CNNVD", "id": "CNNVD-202207-950" }, { "db": "NVD", "id": "CVE-2022-26647" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-07-14T00:00:00", "db": "CNVD", "id": "CNVD-2022-51440" }, { "date": "2022-07-12T00:00:00", "db": "VULMON", "id": "CVE-2022-26647" }, { "date": "2022-07-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202207-950" }, { "date": "2022-07-12T10:15:10.257000", "db": "NVD", "id": "CVE-2022-26647" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-07-14T00:00:00", "db": "CNVD", "id": "CNVD-2022-51440" }, { "date": "2022-07-15T00:00:00", "db": "VULMON", "id": "CVE-2022-26647" }, { "date": "2023-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202207-950" }, { "date": "2023-04-11T10:15:13.657000", "db": "NVD", "id": "CVE-2022-26647" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-950" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Unknown Vulnerability in Siemens SCALANCE X Switches", "sources": [ { "db": "CNVD", "id": "CNVD-2022-51440" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "security feature problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202207-950" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.