An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The authentication function contains undocumented code that provides the ability to authenticate as root without knowing the actual root password. An adversary with the private key can remotely authenticate to the management interface as root. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0159",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "mofi4500-4gxelte",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mofinetwork",
        "version": "4.1.5-std"
      },
      {
        "model": "network mofi4500-4gxelte 4.1.5-std",
        "scope": null,
        "trust": 0.6,
        "vendor": "mofi",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15835"
      }
    ]
  },
  "cve": "CVE-2020-15835",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2020-15835",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-13965",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-15835",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-15835",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-13965",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-2611",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-15835",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-15835"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2611"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15835"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The authentication function contains undocumented code that provides the ability to authenticate as root without knowing the actual root password. An adversary with the private key can remotely authenticate to the management interface as root. Mofi Network MOFI4500-4GXeLTE is a wireless router of Mofi Network Company",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-15835"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-15835"
      }
    ],
    "trust": 1.53
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-15835",
        "trust": 2.3
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-13965",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2611",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-15835",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-15835"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2611"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15835"
      }
    ]
  },
  "id": "VAR-202102-0159",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      }
    ],
    "trust": 1.6
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:34:52.581000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Mofi Network MOFI4500-4GXeLTE certification bypass vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/250471"
      },
      {
        "title": "Mofi Network MOFI4500-4GXeLTE Remediation measures for authorization problem vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=140642"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2611"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-287",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-15835"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://mofinetwork.com/index.php?main_page=page\u0026id=14"
      },
      {
        "trust": 1.7,
        "url": "https://www.criticalstart.com/critical-vulnerabilities-discovered-in-mofi-routers/"
      },
      {
        "trust": 1.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-15835"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/287.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-15835"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2611"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15835"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-15835"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2611"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15835"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-15835"
      },
      {
        "date": "2021-01-31T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2611"
      },
      {
        "date": "2021-02-01T02:15:15.160000",
        "db": "NVD",
        "id": "CVE-2020-15835"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      },
      {
        "date": "2021-02-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-15835"
      },
      {
        "date": "2021-02-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-2611"
      },
      {
        "date": "2024-11-21T05:06:17.167000",
        "db": "NVD",
        "id": "CVE-2020-15835"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2611"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Mofi Network MOFI4500-4GXeLTE certification bypass vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-13965"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "authorization issue",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-2611"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…