GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

VAR-201809-0915

Vulnerability from variot - Updated: 2024-06-11 22:58

Technicolor TG588V V2 devices allow remote attackers to cause a denial of service (networking outage) via a flood of random MAC addresses, as demonstrated by macof. NOTE: this might overlap CVE-2018-15852 and CVE-2018-15907. NOTE: Technicolor denies that the described behavior is a vulnerability and states that Wi-Fi traffic is slowed or stopped only while the devices are exposed to a MAC flooding attack. This has been confirmed through testing against official up-to-date versions. ** Unsettled ** This case has not been confirmed as a vulnerability. TG588V V2 The device contains vulnerabilities related to security functions. The vendor has disputed this vulnerability. For details, see NVD of Current Description Please Confirm. https://nvd.nist.gov/vuln/detail/CVE-2018-16310Service operation interruption (DoS) There is a possibility of being put into a state. Technicolor TG588V V2 is an ADSL VDSL router.

Technicolor TG588V V2 has a denial of service vulnerability

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201809-0915",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "tg588v",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "technicolor",
        "version": null
      },
      {
        "model": "tg588v",
        "scope": null,
        "trust": 0.8,
        "vendor": "technicolor",
        "version": null
      },
      {
        "model": "tg588v",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "technicolor",
        "version": "v2"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-42721"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009486"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-290"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16310"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:technicolor:tg588v_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:technicolor:tg588v:2:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-16310"
      }
    ]
  },
  "cve": "CVE-2018-16310",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": true,
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Adjacent Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 6.1,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2018-16310",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2019-42721",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "VHN-126657",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2018-16310",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2018-16310",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-42721",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201809-290",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-126657",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-42721"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009486"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-290"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16310"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Technicolor TG588V V2 devices allow remote attackers to cause a denial of service (networking outage) via a flood of random MAC addresses, as demonstrated by macof. NOTE: this might overlap CVE-2018-15852 and CVE-2018-15907. NOTE: Technicolor denies that the described behavior is a vulnerability and states that Wi-Fi traffic is slowed or stopped only while the devices are exposed to a MAC flooding attack. This has been confirmed through testing against official up-to-date versions. ** Unsettled ** This case has not been confirmed as a vulnerability. TG588V V2 The device contains vulnerabilities related to security functions. The vendor has disputed this vulnerability. For details, see NVD of Current Description Please Confirm. https://nvd.nist.gov/vuln/detail/CVE-2018-16310Service operation interruption (DoS) There is a possibility of being put into a state. Technicolor TG588V V2 is an ADSL VDSL router. \n\nTechnicolor TG588V V2 has a denial of service vulnerability",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-16310"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009486"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-42721"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126657"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-16310",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009486",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-290",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-42721",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-126657",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-42721"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009486"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-290"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16310"
      }
    ]
  },
  "id": "VAR-201809-0915",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-42721"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126657"
      }
    ],
    "trust": 1.325
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-42721"
      }
    ]
  },
  "last_update_date": "2024-06-11T22:58:28.126000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.technicolor.com/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009486"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-400",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-254",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-126657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009486"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16310"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "http://buddieshub27.blogspot.com/2018/09/cve-2018-16310-technicolor-tg588v-v2.html"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-16310"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16310"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-42721"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009486"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-290"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16310"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-42721"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126657"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009486"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-290"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16310"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-11-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-42721"
      },
      {
        "date": "2018-09-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-126657"
      },
      {
        "date": "2018-11-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009486"
      },
      {
        "date": "2018-09-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-290"
      },
      {
        "date": "2018-09-06T23:29:01.350000",
        "db": "NVD",
        "id": "CVE-2018-16310"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-11-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-42721"
      },
      {
        "date": "2019-10-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-126657"
      },
      {
        "date": "2018-11-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-009486"
      },
      {
        "date": "2019-10-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201809-290"
      },
      {
        "date": "2024-06-10T21:15:48.783000",
        "db": "NVD",
        "id": "CVE-2018-16310"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-290"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "TG588V V2 Vulnerabilities related to security functions in devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-009486"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "resource management error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201809-290"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…