A vulnerability in the implementation of a specific CLI command and the associated Simple Network Management Protocol (SNMP) MIB for Cisco NX-OS (in standalone NX-OS mode) on Cisco Nexus 3000 and 9000 Series Switches could allow an authenticated, remote attacker to exhaust system memory on an affected device, resulting in a denial of service (DoS) condition. The vulnerability is due to the incorrect implementation of the CLI command, resulting in a failure to free all allocated memory upon completion. An attacker could exploit this vulnerability by authenticating to the affected device and repeatedly issuing a specific CLI command or sending a specific SNMP poll request for a specific Object Identifier (OID). A successful exploit could allow the attacker to cause the IP routing process to restart or to cause a device reset, resulting in a DoS condition. Cisco Bug IDs: CSCvf23136. Cisco NX-OS Contains a resource exhaustion vulnerability. Vendors have confirmed this vulnerability Bug ID CSCvf23136 It is released as.Service operation interruption (DoS) There is a possibility of being put into a state. The Cisco Nexus 3000 and 9000 Series Switches are both different series of switch devices from Cisco. NX-OS is the data center level operating system software used by a set of switches running on it
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201806-0994",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "nx-os",
"scope": "eq",
"trust": 1.6,
"vendor": "cisco",
"version": "7.0\\(3\\)i6\\(1\\)"
},
{
"model": "nx-os",
"scope": "eq",
"trust": 1.6,
"vendor": "cisco",
"version": "7.0\\(3\\)i5\\(2\\)"
},
{
"model": "nx-os",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "nexus series switche",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "3000"
},
{
"model": "nexus series switches",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "9000"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14579"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-006809"
},
{
"db": "CNNVD",
"id": "CNNVD-201806-1123"
},
{
"db": "NVD",
"id": "CVE-2018-0309"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:cisco:nx-os",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-006809"
}
]
},
"cve": "CVE-2018-0309",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "CVE-2018-0309",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2018-14579",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "VHN-118511",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.1,
"id": "CVE-2018-0309",
"impactScore": 4.0,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-0309",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2018-0309",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2018-14579",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201806-1123",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-118511",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14579"
},
{
"db": "VULHUB",
"id": "VHN-118511"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-006809"
},
{
"db": "CNNVD",
"id": "CNNVD-201806-1123"
},
{
"db": "NVD",
"id": "CVE-2018-0309"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability in the implementation of a specific CLI command and the associated Simple Network Management Protocol (SNMP) MIB for Cisco NX-OS (in standalone NX-OS mode) on Cisco Nexus 3000 and 9000 Series Switches could allow an authenticated, remote attacker to exhaust system memory on an affected device, resulting in a denial of service (DoS) condition. The vulnerability is due to the incorrect implementation of the CLI command, resulting in a failure to free all allocated memory upon completion. An attacker could exploit this vulnerability by authenticating to the affected device and repeatedly issuing a specific CLI command or sending a specific SNMP poll request for a specific Object Identifier (OID). A successful exploit could allow the attacker to cause the IP routing process to restart or to cause a device reset, resulting in a DoS condition. Cisco Bug IDs: CSCvf23136. Cisco NX-OS Contains a resource exhaustion vulnerability. Vendors have confirmed this vulnerability Bug ID CSCvf23136 It is released as.Service operation interruption (DoS) There is a possibility of being put into a state. The Cisco Nexus 3000 and 9000 Series Switches are both different series of switch devices from Cisco. NX-OS is the data center level operating system software used by a set of switches running on it",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-0309"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-006809"
},
{
"db": "CNVD",
"id": "CNVD-2018-14579"
},
{
"db": "VULHUB",
"id": "VHN-118511"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-0309",
"trust": 3.1
},
{
"db": "SECTRACK",
"id": "1041169",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2018-006809",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2018-14579",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201806-1123",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-118511",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14579"
},
{
"db": "VULHUB",
"id": "VHN-118511"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-006809"
},
{
"db": "CNNVD",
"id": "CNNVD-201806-1123"
},
{
"db": "NVD",
"id": "CVE-2018-0309"
}
]
},
"id": "VAR-201806-0994",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14579"
},
{
"db": "VULHUB",
"id": "VHN-118511"
}
],
"trust": 1.060873565
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14579"
}
]
},
"last_update_date": "2024-11-23T21:38:48.836000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "cisco-sa-20180620-n3k-n9k-clisnmp",
"trust": 0.8,
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-n3k-n9k-clisnmp"
},
{
"title": "Patch for Cisco Nexus 3000 and 9000 Series Switches NX-OS Denial of Service Vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/136341"
},
{
"title": "Cisco Nexus 3000 and 9000 Series Switches NX-OS Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=81454"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14579"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-006809"
},
{
"db": "CNNVD",
"id": "CNNVD-201806-1123"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-400",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-118511"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-006809"
},
{
"db": "NVD",
"id": "CVE-2018-0309"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-20180620-n3k-n9k-clisnmp"
},
{
"trust": 1.7,
"url": "http://www.securitytracker.com/id/1041169"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-0309"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-0309"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-14579"
},
{
"db": "VULHUB",
"id": "VHN-118511"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-006809"
},
{
"db": "CNNVD",
"id": "CNNVD-201806-1123"
},
{
"db": "NVD",
"id": "CVE-2018-0309"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2018-14579"
},
{
"db": "VULHUB",
"id": "VHN-118511"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-006809"
},
{
"db": "CNNVD",
"id": "CNNVD-201806-1123"
},
{
"db": "NVD",
"id": "CVE-2018-0309"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-14579"
},
{
"date": "2018-06-21T00:00:00",
"db": "VULHUB",
"id": "VHN-118511"
},
{
"date": "2018-08-31T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-006809"
},
{
"date": "2018-06-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201806-1123"
},
{
"date": "2018-06-21T11:29:00.570000",
"db": "NVD",
"id": "CVE-2018-0309"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-08-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-14579"
},
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-118511"
},
{
"date": "2018-08-31T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-006809"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201806-1123"
},
{
"date": "2024-11-21T03:37:56.957000",
"db": "NVD",
"id": "CVE-2018-0309"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201806-1123"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cisco NX-OS Vulnerable to resource exhaustion",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-006809"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "resource management error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201806-1123"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.