var-201805-0356
Vulnerability from variot
Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. Schneider Electric Ampla MES Contains a cryptographic strength vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ampla Manufacturing Execution System (MES) is a manufacturing execution system for on-site production management in production plants and production plants by Schneider Electric. Local attackers can exploit these issues to obtain sensitive information which may aid in further attacks
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201805-0356",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ampla manufacturing execution system",
"scope": "lte",
"trust": 1.8,
"vendor": "schneider electric",
"version": "6.4"
},
{
"model": "ampla manufacturing execution system",
"scope": "eq",
"trust": 0.9,
"vendor": "schneider electric",
"version": "6.4"
},
{
"model": "electric ampla mes",
"scope": "lte",
"trust": 0.6,
"vendor": "schneider",
"version": "\u003c=6.4"
},
{
"model": "ampla manufacturing execution system",
"scope": "eq",
"trust": 0.3,
"vendor": "schneider electric",
"version": "6.0"
},
{
"model": "ampla manufacturing execution system",
"scope": "ne",
"trust": 0.3,
"vendor": "schneider electric",
"version": "6.5"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "ampla manufacturing execution system",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "ba0d2b77-ab21-4236-93a1-bb5f4b9f6f98"
},
{
"db": "CNVD",
"id": "CNVD-2017-22830"
},
{
"db": "BID",
"id": "99469"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-013476"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-868"
},
{
"db": "NVD",
"id": "CVE-2017-9635"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:schneider_electric:ampla_manufacturing_execution_system",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-013476"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ilya Karpov",
"sources": [
{
"db": "BID",
"id": "99469"
}
],
"trust": 0.3
},
"cve": "CVE-2017-9635",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 1.9,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.4,
"id": "CVE-2017-9635",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:L/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CNVD-2017-22830",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "ba0d2b77-ab21-4236-93a1-bb5f4b9f6f98",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "LOW",
"baseScore": 3.9,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"exploitabilityScore": 0.5,
"id": "CVE-2017-9635",
"impactScore": 3.4,
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-9635",
"trust": 1.0,
"value": "LOW"
},
{
"author": "NVD",
"id": "CVE-2017-9635",
"trust": 0.8,
"value": "Low"
},
{
"author": "CNVD",
"id": "CNVD-2017-22830",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201706-868",
"trust": 0.6,
"value": "LOW"
},
{
"author": "IVD",
"id": "ba0d2b77-ab21-4236-93a1-bb5f4b9f6f98",
"trust": 0.2,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "ba0d2b77-ab21-4236-93a1-bb5f4b9f6f98"
},
{
"db": "CNVD",
"id": "CNVD-2017-22830"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-013476"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-868"
},
{
"db": "NVD",
"id": "CVE-2017-9635"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user\u0027s password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. Schneider Electric Ampla MES Contains a cryptographic strength vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Ampla Manufacturing Execution System (MES) is a manufacturing execution system for on-site production management in production plants and production plants by Schneider Electric. \nLocal attackers can exploit these issues to obtain sensitive information which may aid in further attacks",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-9635"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-013476"
},
{
"db": "CNVD",
"id": "CNVD-2017-22830"
},
{
"db": "BID",
"id": "99469"
},
{
"db": "IVD",
"id": "ba0d2b77-ab21-4236-93a1-bb5f4b9f6f98"
}
],
"trust": 2.61
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-9635",
"trust": 3.5
},
{
"db": "ICS CERT",
"id": "ICSA-17-187-05",
"trust": 3.3
},
{
"db": "BID",
"id": "99469",
"trust": 2.5
},
{
"db": "CNVD",
"id": "CNVD-2017-22830",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201706-868",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2017-013476",
"trust": 0.8
},
{
"db": "IVD",
"id": "BA0D2B77-AB21-4236-93A1-BB5F4B9F6F98",
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "ba0d2b77-ab21-4236-93a1-bb5f4b9f6f98"
},
{
"db": "CNVD",
"id": "CNVD-2017-22830"
},
{
"db": "BID",
"id": "99469"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-013476"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-868"
},
{
"db": "NVD",
"id": "CVE-2017-9635"
}
]
},
"id": "VAR-201805-0356",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "ba0d2b77-ab21-4236-93a1-bb5f4b9f6f98"
},
{
"db": "CNVD",
"id": "CNVD-2017-22830"
}
],
"trust": 1.8
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "ba0d2b77-ab21-4236-93a1-bb5f4b9f6f98"
},
{
"db": "CNVD",
"id": "CNVD-2017-22830"
}
]
},
"last_update_date": "2024-11-23T22:17:30.617000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Ampla MES multiple vulnerabilities",
"trust": 0.8,
"url": "https://cdn2.hubspot.net/hubfs/2900448/assets-2018/pdf/security-bulletin/LFSec00000118.pdf"
},
{
"title": "Schneider Electric Ampla Patch for MES Weak Password Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/100846"
},
{
"title": "Schneider Electric Ampla MES Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=99875"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-22830"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-013476"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-868"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-326",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-013476"
},
{
"db": "NVD",
"id": "CVE-2017-9635"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.3,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-17-187-05"
},
{
"trust": 2.2,
"url": "http://www.securityfocus.com/bid/99469"
},
{
"trust": 1.6,
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000118/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-9635"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-9635"
},
{
"trust": 0.3,
"url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-22830"
},
{
"db": "BID",
"id": "99469"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-013476"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-868"
},
{
"db": "NVD",
"id": "CVE-2017-9635"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "ba0d2b77-ab21-4236-93a1-bb5f4b9f6f98"
},
{
"db": "CNVD",
"id": "CNVD-2017-22830"
},
{
"db": "BID",
"id": "99469"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-013476"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-868"
},
{
"db": "NVD",
"id": "CVE-2017-9635"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-08-25T00:00:00",
"db": "IVD",
"id": "ba0d2b77-ab21-4236-93a1-bb5f4b9f6f98"
},
{
"date": "2017-08-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-22830"
},
{
"date": "2017-07-06T00:00:00",
"db": "BID",
"id": "99469"
},
{
"date": "2018-07-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-013476"
},
{
"date": "2017-06-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201706-868"
},
{
"date": "2018-05-18T13:29:00.223000",
"db": "NVD",
"id": "CVE-2017-9635"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-08-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-22830"
},
{
"date": "2017-07-06T00:00:00",
"db": "BID",
"id": "99469"
},
{
"date": "2018-07-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-013476"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201706-868"
},
{
"date": "2024-11-21T03:36:33.690000",
"db": "NVD",
"id": "CVE-2017-9635"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "BID",
"id": "99469"
},
{
"db": "CNNVD",
"id": "CNNVD-201706-868"
}
],
"trust": 0.9
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric Ampla MES Weak password vulnerability",
"sources": [
{
"db": "IVD",
"id": "ba0d2b77-ab21-4236-93a1-bb5f4b9f6f98"
},
{
"db": "CNVD",
"id": "CNVD-2017-22830"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "encryption problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201706-868"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.