var-201805-0250
Vulnerability from variot

In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an information exposure vulnerability through directory listing has been identified, which may allow an attacker to find important files that are not normally visible. Advantech WebAccess Contains a vulnerability in the disclosure of file and directory information.Information may be obtained. Advantech WebAccess and others are products of Advantech. Advantech WebAccess is a browser-based HMI/SCADA software. The software supports dynamic graphical display and real-time data control, and provides the ability to remotely control and manage automation equipment. WebAccess Dashboard is one of the dashboard components; WebAccess Scada Node is one of the monitoring node components. WebAccess/NMS is a suite of web browsers for the Network Management System (NMS). Security vulnerabilities exist in several Advantech products. An attacker could exploit this vulnerability to obtain important files that are not visible. Multiple SQL-injection vulnerabilities 2. An information-disclosure vulnerability 3. A file-upload vulnerability 4. Multiple directory-traversal vulnerabilities 5. Multiple stack-based buffer-overflow vulnerabilities 6. A heap-based buffer-overflow vulnerability 7. Multiple arbitrary code-execution vulnerabilities 8. A denial-of-service vulnerability 9. A security-bypass vulnerability 10. A privilege-escalation vulnerability An attacker can exploit these issues to execute arbitrary code in the context of the application, or modify data, or exploit latent vulnerabilities in the underlying database, delete arbitrary files, gain elevated privileges, perform certain unauthorized actions, upload arbitrary files to the affected application gain unauthorized access and obtain sensitive information. Failed attacks will cause denial of service conditions. Advantech WebAccess, etc. Advantech WebAccess is a set of HMI/SCADA software based on browser architecture. The following versions are affected: Advantech WebAccess 8.2_20170817 and earlier, 8.3.0 and earlier; WebAccess Dashboard 2.0.15 and earlier; WebAccess Scada Node 8.3.1 and earlier; WebAccess/NMS 2.0.3 and earlier

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201805-0250",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "webaccess",
        "scope": "lte",
        "trust": 1.8,
        "vendor": "advantech",
        "version": "8.2_20170817"
      },
      {
        "model": "webaccess",
        "scope": "lte",
        "trust": 1.8,
        "vendor": "advantech",
        "version": "8.3.0"
      },
      {
        "model": "webaccess dashboard",
        "scope": "lte",
        "trust": 1.8,
        "vendor": "advantech",
        "version": "2.0.15"
      },
      {
        "model": "webaccess scada node",
        "scope": "lt",
        "trust": 1.4,
        "vendor": "advantech",
        "version": "8.3.1"
      },
      {
        "model": "webaccess\\/nms",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "advantech",
        "version": "2.0.3"
      },
      {
        "model": "webaccess scada",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "advantech",
        "version": "8.3.1"
      },
      {
        "model": "webaccess dashboard",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "advantech",
        "version": "2.0.15"
      },
      {
        "model": "webaccess/nms",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "advantech",
        "version": "2.0.3"
      },
      {
        "model": "webaccess dashboard",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "advantech",
        "version": "\u003c=2.0.15"
      },
      {
        "model": "webaccess/nms",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "advantech",
        "version": "\u003c=2.0.3"
      },
      {
        "model": "webaccess",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "advantech",
        "version": "8.3.0"
      },
      {
        "model": "webaccess",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "advantech",
        "version": "8.2_20170817"
      },
      {
        "model": "webaccess\\/nms",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "advantech",
        "version": "2.0.3"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "webaccess",
        "version": "*"
      },
      {
        "model": "webaccess/nms",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "2.0.3"
      },
      {
        "model": "webaccess/nms",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "2.0"
      },
      {
        "model": "webaccess scada node",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "8.3"
      },
      {
        "model": "webaccess dashboard",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "2.0"
      },
      {
        "model": "webaccess",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "8.3"
      },
      {
        "model": "webaccess 8.2 20170817",
        "scope": null,
        "trust": 0.3,
        "vendor": "advantech",
        "version": null
      },
      {
        "model": "webaccess 8.2 20170330",
        "scope": null,
        "trust": 0.3,
        "vendor": "advantech",
        "version": null
      },
      {
        "model": "webaccess",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "8.2"
      },
      {
        "model": "webaccess 8.1 20160519",
        "scope": null,
        "trust": 0.3,
        "vendor": "advantech",
        "version": null
      },
      {
        "model": "webaccess",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "8.1"
      },
      {
        "model": "webaccess 8.0 20150816",
        "scope": null,
        "trust": 0.3,
        "vendor": "advantech",
        "version": null
      },
      {
        "model": "webaccess",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "8"
      },
      {
        "model": "webaccess",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "8.3.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "webaccess dashboard",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "webaccess scada",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "webaccess nms",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2ef868f-39ab-11e9-8037-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-09823"
      },
      {
        "db": "BID",
        "id": "104190"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-450"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10590"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:advantech:advantech_webaccess",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:advantech:webaccess_dashboard",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:advantech:webaccess_scada",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:advantech:webaccess%2fnms",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Mat Powell, rgod, Steven Seeley, Donato Onofri and Simone Onofri",
    "sources": [
      {
        "db": "BID",
        "id": "104190"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2018-10590",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-10590",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-09823",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "e2ef868f-39ab-11e9-8037-000c29342cb1",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-120365",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-10590",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-10590",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-10590",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-09823",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201805-450",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "e2ef868f-39ab-11e9-8037-000c29342cb1",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-120365",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2ef868f-39ab-11e9-8037-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-09823"
      },
      {
        "db": "VULHUB",
        "id": "VHN-120365"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-450"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10590"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an information exposure vulnerability through directory listing has been identified, which may allow an attacker to find important files that are not normally visible. Advantech WebAccess Contains a vulnerability in the disclosure of file and directory information.Information may be obtained. Advantech WebAccess and others are products of Advantech. Advantech WebAccess is a browser-based HMI/SCADA software. The software supports dynamic graphical display and real-time data control, and provides the ability to remotely control and manage automation equipment. WebAccess Dashboard is one of the dashboard components; WebAccess Scada Node is one of the monitoring node components. WebAccess/NMS is a suite of web browsers for the Network Management System (NMS). Security vulnerabilities exist in several Advantech products. An attacker could exploit this vulnerability to obtain important files that are not visible. Multiple SQL-injection vulnerabilities\n2. An information-disclosure vulnerability\n3. A file-upload vulnerability\n4. Multiple directory-traversal vulnerabilities\n5. Multiple stack-based buffer-overflow vulnerabilities\n6. A heap-based buffer-overflow vulnerability\n7. Multiple arbitrary code-execution vulnerabilities\n8. A denial-of-service vulnerability\n9. A security-bypass vulnerability\n10. A privilege-escalation vulnerability\nAn attacker can exploit these issues to execute arbitrary code in the  context of the application, or modify data, or exploit latent   vulnerabilities in the underlying database,  delete arbitrary files,  gain elevated privileges, perform certain unauthorized actions, upload  arbitrary files to the affected application gain unauthorized access and  obtain sensitive information. Failed attacks will cause denial of  service conditions. Advantech WebAccess, etc. Advantech WebAccess is a set of HMI/SCADA software based on browser architecture. The following versions are affected: Advantech WebAccess 8.2_20170817 and earlier, 8.3.0 and earlier; WebAccess Dashboard 2.0.15 and earlier; WebAccess Scada Node 8.3.1 and earlier; WebAccess/NMS 2.0.3 and earlier",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-10590"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-09823"
      },
      {
        "db": "BID",
        "id": "104190"
      },
      {
        "db": "IVD",
        "id": "e2ef868f-39ab-11e9-8037-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-120365"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-10590",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-135-01",
        "trust": 3.4
      },
      {
        "db": "BID",
        "id": "104190",
        "trust": 2.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-09823",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-450",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-005068",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "E2EF868F-39AB-11E9-8037-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-120365",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2ef868f-39ab-11e9-8037-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-09823"
      },
      {
        "db": "VULHUB",
        "id": "VHN-120365"
      },
      {
        "db": "BID",
        "id": "104190"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-450"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10590"
      }
    ]
  },
  "id": "VAR-201805-0250",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2ef868f-39ab-11e9-8037-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-09823"
      },
      {
        "db": "VULHUB",
        "id": "VHN-120365"
      }
    ],
    "trust": 1.5434040525000001
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2ef868f-39ab-11e9-8037-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-09823"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:53:07.924000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Advantech WebAccess",
        "trust": 0.8,
        "url": "http://www.advantech.com/industrial-automation/webaccess/webaccessscada"
      },
      {
        "title": "Patch for Advantech WebAccess Information Disclosure Vulnerability (CNVD-2018-09823)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/129391"
      },
      {
        "title": "Multiple Advantech Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=80060"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-09823"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-450"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-538",
        "trust": 1.9
      },
      {
        "problemtype": "CWE-548",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-120365"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10590"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.4,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-135-01"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/104190"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-10590"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-10590"
      },
      {
        "trust": 0.3,
        "url": "http://webaccess.advantech.com"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-09823"
      },
      {
        "db": "VULHUB",
        "id": "VHN-120365"
      },
      {
        "db": "BID",
        "id": "104190"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-450"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10590"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e2ef868f-39ab-11e9-8037-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-09823"
      },
      {
        "db": "VULHUB",
        "id": "VHN-120365"
      },
      {
        "db": "BID",
        "id": "104190"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-450"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-10590"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-05-18T00:00:00",
        "db": "IVD",
        "id": "e2ef868f-39ab-11e9-8037-000c29342cb1"
      },
      {
        "date": "2018-05-17T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-09823"
      },
      {
        "date": "2018-05-15T00:00:00",
        "db": "VULHUB",
        "id": "VHN-120365"
      },
      {
        "date": "2018-05-15T00:00:00",
        "db": "BID",
        "id": "104190"
      },
      {
        "date": "2018-07-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      },
      {
        "date": "2018-05-16T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201805-450"
      },
      {
        "date": "2018-05-15T22:29:00.317000",
        "db": "NVD",
        "id": "CVE-2018-10590"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-05-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-09823"
      },
      {
        "date": "2019-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-120365"
      },
      {
        "date": "2018-05-15T00:00:00",
        "db": "BID",
        "id": "104190"
      },
      {
        "date": "2018-07-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201805-450"
      },
      {
        "date": "2024-11-21T03:41:37.093000",
        "db": "NVD",
        "id": "CVE-2018-10590"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-450"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Advantech WebAccess Vulnerable to file and directory information disclosure",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-005068"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "lack of information",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201805-450"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.