VAR-201802-1281

Vulnerability from variot - Updated: 2023-12-18 12:57

eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices. eQ-3 AG HomeMatic CCU2 Devices are vulnerable to a lack of authentication for critical functions.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The eQ-3AGHomematicCCU2 is a central control unit for the German eQ-3 company that controls smart home devices. A security vulnerability exists in the eQ-3AGHomeMaticCCU 22.29.22 release

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201802-1281",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "homematic central control unit ccu2",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "eq 3",
        "version": "2.29.22"
      },
      {
        "model": "homematic zentrale ccu2",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "eq 3",
        "version": "2.29.22"
      },
      {
        "model": "ag homematic ccu2",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "eq 3",
        "version": "2.29.22"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-05827"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002350"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7301"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-552"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:eq-3:homematic_central_control_unit_ccu2_firmware:2.29.22:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:eq-3:homematic_central_control_unit_ccu2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-7301"
      }
    ]
  },
  "cve": "CVE-2018-7301",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2018-7301",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-05827",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-137333",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2018-7301",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2018-7301",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-05827",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201802-552",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-137333",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-05827"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002350"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7301"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-552"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "eQ-3 AG HomeMatic CCU2 2.29.22 devices have an open XML-RPC port without authentication. This can be exploited by sending arbitrary XML-RPC requests to control the attached BidCos devices. eQ-3 AG HomeMatic CCU2 Devices are vulnerable to a lack of authentication for critical functions.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The eQ-3AGHomematicCCU2 is a central control unit for the German eQ-3 company that controls smart home devices. A security vulnerability exists in the eQ-3AGHomeMaticCCU 22.29.22 release",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-7301"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002350"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-05827"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137333"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-7301",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002350",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-552",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-05827",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-137333",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-05827"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002350"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7301"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-552"
      }
    ]
  },
  "id": "VAR-201802-1281",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-05827"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137333"
      }
    ],
    "trust": 1.7
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-05827"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:57:03.178000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "HomeMatic Zentrale CCU2",
        "trust": 0.8,
        "url": "http://www.eq-3.de/produkte/homematic/zentralen-und-gateways/homematic-zentrale-ccu-2.html"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002350"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-306",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-137333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002350"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7301"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "http://atomic111.github.io/article/homematic-ccu2-xml-rpc"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-7301"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-7301"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-05827"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002350"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7301"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-552"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-05827"
      },
      {
        "db": "VULHUB",
        "id": "VHN-137333"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002350"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-7301"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-552"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-05827"
      },
      {
        "date": "2018-02-22T00:00:00",
        "db": "VULHUB",
        "id": "VHN-137333"
      },
      {
        "date": "2018-04-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-002350"
      },
      {
        "date": "2018-02-22T19:29:06.547000",
        "db": "NVD",
        "id": "CVE-2018-7301"
      },
      {
        "date": "2018-03-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201802-552"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-05827"
      },
      {
        "date": "2018-03-18T00:00:00",
        "db": "VULHUB",
        "id": "VHN-137333"
      },
      {
        "date": "2018-04-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-002350"
      },
      {
        "date": "2018-03-18T14:18:12.980000",
        "db": "NVD",
        "id": "CVE-2018-7301"
      },
      {
        "date": "2018-03-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201802-552"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-552"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "eQ-3 AG HomeMatic CCU2 Vulnerability related to lack of authentication for critical functions on devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-002350"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "lack of information",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201802-552"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…