ssa-773256
Vulnerability from csaf_siemens
Published
2024-09-10 00:00
Modified
2024-11-12 00:00
Summary
SSA-773256: Impact of Socket.IO CVE-2024-38355 on Siemens Industrial Products

Notes

Summary
A Socket.IO vulnerability affects multiple Siemens industrial products. This vulnerability consists of a specially crafted Socket.IO packet that triggers an uncaught exception on the Socket.IO server killing the Node.js process allowing a remote attacker to cause Denial-of-Service condition in the affected products. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.



{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "A Socket.IO vulnerability affects multiple Siemens industrial products. This vulnerability consists of a specially crafted Socket.IO packet that triggers an uncaught exception on the Socket.IO server killing the Node.js process allowing a remote attacker to cause Denial-of-Service condition in the affected products.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-773256: Impact of Socket.IO CVE-2024-38355 on Siemens Industrial Products - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-773256.html"
      },
      {
        "category": "self",
        "summary": "SSA-773256: Impact of Socket.IO CVE-2024-38355 on Siemens Industrial Products - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-773256.json"
      }
    ],
    "title": "SSA-773256: Impact of Socket.IO CVE-2024-38355 on Siemens Industrial Products",
    "tracking": {
      "current_release_date": "2024-11-12T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-773256",
      "initial_release_date": "2024-09-10T00:00:00Z",
      "revision_history": [
        {
          "date": "2024-09-10T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2024-11-12T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Added fix releases for SIMATIC WinCC V8.0, SIMATIC WinCC V7.5, and SIMATIC WinCC Runtime Professional V18"
        }
      ],
      "status": "interim",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV1.1",
                "product": {
                  "name": "AI Model Deployer",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "AI Model Deployer"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV0.0.6",
                "product": {
                  "name": "Data Flow Monitoring Industrial Edge Device User Interface (DFM IED UI)",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "Data Flow Monitoring Industrial Edge Device User Interface (DFM IED UI)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/\u003cV2.4",
                "product": {
                  "name": "LiveTwin Industrial Edge app (6AV2170-0BL00-0AA0)",
                  "product_id": "3",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6AV2170-0BL00-0AA0"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "LiveTwin Industrial Edge app (6AV2170-0BL00-0AA0)"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V4.1 Update 2",
                "product": {
                  "name": "SIMATIC PCS neo V4.1",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC PCS neo V4.1"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC PCS neo V5.0",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC PCS neo V5.0"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC Runtime Professional V17",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC Runtime Professional V17"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V18 Update 5",
                "product": {
                  "name": "SIMATIC WinCC Runtime Professional V18",
                  "product_id": "7"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC Runtime Professional V18"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC Runtime Professional V19",
                  "product_id": "8"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC Runtime Professional V19"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC Runtime Professional V20",
                  "product_id": "9"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC Runtime Professional V20"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SIMATIC WinCC V7.4",
                  "product_id": "10"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC V7.4"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V7.5 SP2 Update 18",
                "product": {
                  "name": "SIMATIC WinCC V7.5",
                  "product_id": "11"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC V7.5"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V8.0 Update 5",
                "product": {
                  "name": "SIMATIC WinCC V8.0",
                  "product_id": "12"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMATIC WinCC V8.0"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V3.0 SP3",
                "product": {
                  "name": "TIA Administrator",
                  "product_id": "13"
                }
              }
            ],
            "category": "product_name",
            "name": "TIA Administrator"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2024-38355",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Socket.IO is an open source, real-time, bidirectional, event-based, communication framework. A specially crafted Socket.IO packet can trigger an uncaught exception on the Socket.IO server, thus killing the Node.js process. This issue is fixed by commit `15af22fc22` which has been included in `socket.io@4.6.2` (released in May 2023). The fix was backported in the 2.x branch as well with commit `d30630ba10`. Users are advised to upgrade. Users unable to upgrade may attach a listener for the \"error\" event to catch these errors.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8",
          "9",
          "10",
          "11",
          "12",
          "13"
        ]
      },
      "remediations": [
        {
          "category": "no_fix_planned",
          "details": "Currently no fix is planned",
          "product_ids": [
            "6",
            "10"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "5",
            "8",
            "9"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V0.0.6 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://iehub.eu1.edge.siemens.cloud/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V1.1 or later version",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V18 Update 5 or later version",
          "product_ids": [
            "7"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V2.4 or later version",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V3.0 SP3 or later version",
          "product_ids": [
            "13"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.1 Update 2 or later version",
          "product_ids": [
            "4"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V7.5 SP2 Update 18 or later version",
          "product_ids": [
            "11"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109793460/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V8.0 Update 5 or later version",
          "product_ids": [
            "12"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8",
            "9",
            "10",
            "11",
            "12",
            "13"
          ]
        }
      ],
      "title": "CVE-2024-38355"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.