ssa-669158
Vulnerability from csaf_siemens
Published
2021-04-13 00:00
Modified
2022-03-08 00:00
Summary
SSA-669158: DNS Client Vulnerabilities in SIMOTICS CONNECT 400

Notes

Summary
SIMOTICS CONNECT 400 is affected by DNS Client vulnerabilities as initially reported in Siemens Security Advisory SSA-705111 (https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf) for the DNS Module in Nucleus RTOS. Siemens has released updates for the SIMOTICS CONNECT 400 and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.



{
  "document": {
    "acknowledgments": [
      {
        "names": [
          "Daniel dos Santos"
        ],
        "organization": "Forescout Technologies Inc.",
        "summary": "coordinated disclosure"
      }
    ],
    "category": "Siemens Security Advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "SIMOTICS CONNECT 400 is affected by DNS Client vulnerabilities as initially reported in Siemens Security Advisory SSA-705111 (https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf) for the DNS Module in Nucleus RTOS.\n\nSiemens has released updates for the SIMOTICS CONNECT 400 and recommends to update to the latest version.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-669158: DNS Client Vulnerabilities in SIMOTICS CONNECT 400 - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-669158: DNS Client Vulnerabilities in SIMOTICS CONNECT 400 - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-669158.txt"
      },
      {
        "category": "self",
        "summary": "SSA-669158: DNS Client Vulnerabilities in SIMOTICS CONNECT 400 - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-669158.json"
      }
    ],
    "title": "SSA-669158: DNS Client Vulnerabilities in SIMOTICS CONNECT 400",
    "tracking": {
      "current_release_date": "2022-03-08T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-669158",
      "initial_release_date": "2021-04-13T00:00:00Z",
      "revision_history": [
        {
          "date": "2021-04-13T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2022-03-08T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Added solution for CVE-2021-25677"
        }
      ],
      "status": "final",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V0.5.0.0",
                "product": {
                  "name": "SIMOTICS CONNECT 400",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMOTICS CONNECT 400"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003e= V0.5.0.0 \u003c V1.0.0.0",
                "product": {
                  "name": "SIMOTICS CONNECT 400",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "SIMOTICS CONNECT 400"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2020-27736",
      "cwe": {
        "id": "CWE-170",
        "name": "Improper Null Termination"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27736 - SIMOTICS CONNECT 400",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109778383/"
        },
        {
          "summary": "CVE-2020-27736 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27736.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V0.5.0.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109778383/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2020-27736"
    },
    {
      "cve": "CVE-2020-27737",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27737 - SIMOTICS CONNECT 400",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109778383/"
        },
        {
          "summary": "CVE-2020-27737 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27737.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V0.5.0.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109778383/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2020-27737"
    },
    {
      "cve": "CVE-2020-27738",
      "cwe": {
        "id": "CWE-788",
        "name": "Access of Memory Location After End of Buffer"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27738 - SIMOTICS CONNECT 400",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109778383/"
        },
        {
          "summary": "CVE-2020-27738 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27738.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V0.5.0.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109778383/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2020-27738"
    },
    {
      "cve": "CVE-2021-25677",
      "cwe": {
        "id": "CWE-330",
        "name": "Use of Insufficiently Random Values"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25677 - SIMOTICS CONNECT 400",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109778383/"
        },
        {
          "summary": "CVE-2021-25677 - SIMOTICS CONNECT 400",
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109778383/"
        },
        {
          "summary": "CVE-2021-25677 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25677.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V0.5.0.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109778383/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V1.0.0.0 or later version",
          "product_ids": [
            "2"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109778383/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2021-25677"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…