ssa-654775
Vulnerability from csaf_siemens
Published
2022-02-08 00:00
Modified
2022-02-08 00:00
Summary
SSA-654775: Open Redirect Vulnerability in SINEMA Remote Connect Server

Notes

Summary
An open redirect vulnerability in SINEMA Remote Connect Server could allow an attacker to steal logon credentials with a specially crafted malicious link. Siemens has released software update for the SINEMA Remote Connect Server and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.



{
  "document": {
    "acknowledgments": [
      {
        "organization": "SEC Consult Vulnerability Lab",
        "summary": "coordinated disclosure"
      }
    ],
    "category": "Siemens Security Advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "An open redirect vulnerability in SINEMA Remote Connect Server could allow an attacker to steal logon credentials with a specially crafted malicious link.\n\nSiemens has released software update for the SINEMA Remote Connect Server and recommends to update to the latest version.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-654775: Open Redirect Vulnerability in SINEMA Remote Connect Server - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-654775.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-654775: Open Redirect Vulnerability in SINEMA Remote Connect Server - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-654775.txt"
      },
      {
        "category": "self",
        "summary": "SSA-654775: Open Redirect Vulnerability in SINEMA Remote Connect Server - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-654775.json"
      }
    ],
    "title": "SSA-654775: Open Redirect Vulnerability in SINEMA Remote Connect Server",
    "tracking": {
      "current_release_date": "2022-02-08T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-654775",
      "initial_release_date": "2022-02-08T00:00:00Z",
      "revision_history": [
        {
          "date": "2022-02-08T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V2.0",
                "product": {
                  "name": "SINEMA Remote Connect Server",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "SINEMA Remote Connect Server"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-23102",
      "cwe": {
        "id": "CWE-601",
        "name": "URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected products contain an open redirect vulnerability.\n\nAn attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "references": [
        {
          "summary": "CVE-2022-23102 - SINEMA Remote Connect Server",
          "url": "https://support.industry.siemens.com/cs/document/109793790/"
        },
        {
          "summary": "CVE-2022-23102 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2022-23102.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V2.0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/document/109793790/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2022-23102"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…