ssa-634640
Vulnerability from csaf_siemens
Published
2025-04-08 00:00
Modified
2025-07-08 00:00
Summary
SSA-634640: Weak Authentication Vulnerability in Siemens Industrial Edge Devices
Notes
Summary
Siemens Industrial Edge Devices contain a weak authentication vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.
Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Siemens Industrial Edge Devices contain a weak authentication vulnerability that could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-634640: Weak Authentication Vulnerability in Siemens Industrial Edge Devices - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-634640.html"
},
{
"category": "self",
"summary": "SSA-634640: Weak Authentication Vulnerability in Siemens Industrial Edge Devices - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-634640.json"
}
],
"title": "SSA-634640: Weak Authentication Vulnerability in Siemens Industrial Edge Devices",
"tracking": {
"current_release_date": "2025-07-08T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-634640",
"initial_release_date": "2025-04-08T00:00:00Z",
"revision_history": [
{
"date": "2025-04-08T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-07-08T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for SCALANCE LPE9413 (6GK5998-3GS01-2AC2)"
}
],
"status": "interim",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V1.21.1-1-a",
"product": {
"name": "Industrial Edge Own Device (IEOD)",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Industrial Edge Own Device (IEOD)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V1.21.1-1-a",
"product": {
"name": "Industrial Edge Virtual Device",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Industrial Edge Virtual Device"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.1",
"product": {
"name": "SCALANCE LPE9413 (6GK5998-3GS01-2AC2)",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"6GK5998-3GS01-2AC2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE LPE9413 (6GK5998-3GS01-2AC2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.0",
"product": {
"name": "SIMATIC IPC127E Industrial Edge Device",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC127E Industrial Edge Device"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.0",
"product": {
"name": "SIMATIC IPC227E Industrial Edge Device",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC227E Industrial Edge Device"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.0",
"product": {
"name": "SIMATIC IPC427E Industrial Edge Device",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC427E Industrial Edge Device"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.0",
"product": {
"name": "SIMATIC IPC847E Industrial Edge Device",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC847E Industrial Edge Device"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.0",
"product": {
"name": "SIMATIC IPC BX-39A Industrial Edge Device",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC BX-39A Industrial Edge Device"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.0",
"product": {
"name": "SIMATIC IPC BX-59A Industrial Edge Device",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "SIMATIC IPC BX-59A Industrial Edge Device"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-54092",
"cwe": {
"id": "CWE-1390",
"name": "Weak Authentication"
},
"notes": [
{
"category": "summary",
"text": "Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Ensure network access to affected products is limited to trusted parties only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
{
"category": "vendor_fix",
"details": "Update to V1.21.1-1-a or later version",
"product_ids": [
"1"
],
"url": "https://docs.industrial-operations-x.siemens.cloud/r/en-us/v25.02/industrial-edge-platform-operation-what-s-new/device-release-notes/release-notes-industrial-edge-own-device"
},
{
"category": "vendor_fix",
"details": "Update to V1.21.1-1-a or later version",
"product_ids": [
"2"
],
"url": "https://docs.industrial-operations-x.siemens.cloud/r/en-us/v25.02/industrial-edge-platform-operation-what-s-new/device-release-notes/release-notes-industrial-edge-virtual-device"
},
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"3"
],
"url": "https://docs.eu1.edge.siemens.cloud/release_notes/device_release_notes/LPE9413.html"
},
{
"category": "vendor_fix",
"details": "Update to V3.0 or later version",
"product_ids": [
"4",
"5",
"6",
"7",
"8",
"9"
],
"url": "https://docs.industrial-operations-x.siemens.cloud/r/en-us/v3.0/simatic-ipc-ied-os/release-notes"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9"
]
}
],
"title": "CVE-2024-54092"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…