SSA-423808: Multiple NULL Pointer Dereference Vulnerabilities in Industrial Products
Notes
Summary
Multiple NULL pointer dereference vulnerabilities in the affected products could allow an attacker with network access to the webserver, to perform a denial of service attack.
Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Multiple NULL pointer dereference vulnerabilities in the affected products could allow an attacker with network access to the webserver, to perform a denial of service attack.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-423808: Multiple NULL Pointer Dereference Vulnerabilities in Industrial Products - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-423808.html" }, { "category": "self", "summary": "SSA-423808: Multiple NULL Pointer Dereference Vulnerabilities in Industrial Products - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-423808.json" } ], "title": "SSA-423808: Multiple NULL Pointer Dereference Vulnerabilities in Industrial Products", "tracking": { "current_release_date": "2024-09-10T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-423808", "initial_release_date": "2024-09-10T00:00:00Z", "revision_history": [ { "date": "2024-09-10T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV3.5.20", "product": { "name": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "product_id": "1" } } ], "category": "product_name", "name": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV3.5.20", "product": { "name": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "product_id": "2" } } ], "category": "product_name", "name": "SIMATIC CP 1243-1 (incl. SIPLUS variants)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV3.5.20", "product": { "name": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "product_id": "3" } } ], "category": "product_name", "name": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV3.5.20", "product": { "name": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "product_id": "4" } } ], "category": "product_name", "name": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV3.5.20", "product": { "name": "SIMATIC CP 1243-7 LTE", "product_id": "5" } } ], "category": "product_name", "name": "SIMATIC CP 1243-7 LTE" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV3.5.20", "product": { "name": "SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0)", "product_id": "6", "product_identification_helper": { "model_numbers": [ "6GK7243-8RX30-0XE0" ] } } } ], "category": "product_name", "name": "SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "product_id": "7" } } ], "category": "product_name", "name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC IPC DiagBase", "product_id": "8" } } ], "category": "product_name", "name": "SIMATIC IPC DiagBase" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC IPC DiagMonitor", "product_id": "9" } } ], "category": "product_name", "name": "SIMATIC IPC DiagMonitor" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC WinCC Runtime Advanced", "product_id": "10" } } ], "category": "product_name", "name": "SIMATIC WinCC Runtime Advanced" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV2.4.8", "product": { "name": "SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)", "product_id": "11", "product_identification_helper": { "model_numbers": [ "6AG1543-1MX00-7XE0" ] } } } ], "category": "product_name", "name": "SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/\u003cV2.4.8", "product": { "name": "TIM 1531 IRC (6GK7543-1MX00-0XE0)", "product_id": "12", "product_identification_helper": { "model_numbers": [ "6GK7543-1MX00-0XE0" ] } } } ], "category": "product_name", "name": "TIM 1531 IRC (6GK7543-1MX00-0XE0)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-28827", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The web server of the affected devices do not properly handle certain requests, causing a timeout in the watchdog, which could lead to the clean up of pointers. \r\n\r\nThis could allow a remote attacker to cause a denial of service condition in the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "7", "8", "9", "10" ] }, { "category": "vendor_fix", "details": "Update to V2.4.8 or later version", "product_ids": [ "11", "12" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109954889/" }, { "category": "vendor_fix", "details": "Update to V3.5.20 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972735/" }, { "category": "workaround", "details": "Disable the web server of the affected system", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12" ] } ], "title": "CVE-2023-28827" }, { "cve": "CVE-2023-30755", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources. \r\n\r\nThis could allow a remote attacker with elevated privileges to cause a denial of service condition in the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "7", "8", "9", "10" ] }, { "category": "vendor_fix", "details": "Update to V2.4.8 or later version", "product_ids": [ "11", "12" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109954889/" }, { "category": "vendor_fix", "details": "Update to V3.5.20 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972735/" }, { "category": "workaround", "details": "Disable the web server of the affected system", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12" ] } ], "title": "CVE-2023-30755" }, { "cve": "CVE-2023-30756", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The web server of the affected devices do not properly handle certain errors when using the Expect HTTP request header, resulting in NULL dereference.\r\n\r\nThis could allow a remote attacker with no privileges to cause a denial of service condition in the system.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "7", "8", "9", "10" ] }, { "category": "vendor_fix", "details": "Update to V2.4.8 or later version", "product_ids": [ "11", "12" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109954889/" }, { "category": "vendor_fix", "details": "Update to V3.5.20 or later version", "product_ids": [ "1", "2", "3", "4", "5", "6" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972735/" }, { "category": "workaround", "details": "Disable the web server of the affected system", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12" ] } ], "title": "CVE-2023-30756" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.