SSA-327438: Multiple Vulnerabilities in SCALANCE LPE9403

Notes

Summary
SCALANCE LPE9403 is affected by multiple vulnerabilities which lead to a compromise in availability, integrity and confidentiality. Siemens has released a new version for SCALANCE LPE9403 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.



{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en",
    "notes": [
      {
        "category": "summary",
        "text": "SCALANCE LPE9403 is affected by multiple vulnerabilities which lead to a compromise in availability, integrity and confidentiality.\n\nSiemens has released a new version for SCALANCE LPE9403 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-327438: Multiple Vulnerabilities in SCALANCE LPE9403 - HTML Version",
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-327438.html"
      },
      {
        "category": "self",
        "summary": "SSA-327438: Multiple Vulnerabilities in SCALANCE LPE9403 - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-327438.json"
      }
    ],
    "title": "SSA-327438: Multiple Vulnerabilities in SCALANCE LPE9403",
    "tracking": {
      "current_release_date": "2025-07-08T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-327438",
      "initial_release_date": "2025-05-13T00:00:00Z",
      "revision_history": [
        {
          "date": "2025-05-13T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2025-07-08T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Added fix for CVE-2025-40572, CVE-2025-40573, CVE-2025-40574, CVE-2025-40575, CVE-2025-40576, CVE-2025-40577, CVE-2025-40579, CVE-2025-40580"
        }
      ],
      "status": "interim",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "All versions \u003c V4.0 HF0",
                "product": {
                  "name": "SCALANCE LPE9403 (6GK5998-3GS00-2AC2)",
                  "product_id": "1",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5998-3GS00-2AC2"
                    ]
                  }
                }
              },
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SCALANCE LPE9403 (6GK5998-3GS00-2AC2)",
                  "product_id": "2",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5998-3GS00-2AC2"
                    ]
                  }
                }
              },
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "SCALANCE LPE9403 (6GK5998-3GS00-2AC2)",
                  "product_id": "3",
                  "product_identification_helper": {
                    "model_numbers": [
                      "6GK5998-3GS00-2AC2"
                    ]
                  }
                }
              }
            ],
            "category": "product_name",
            "name": "SCALANCE LPE9403 (6GK5998-3GS00-2AC2)"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2025-40572",
      "cwe": {
        "id": "CWE-732",
        "name": "Incorrect Permission Assignment for Critical Resource"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do not properly assign permissions to critical ressources.\r\nThis could allow a non-privileged local attacker to access sensitive information stored on the device.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Restrict access to authorized and trusted personal only",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.0 HF0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109989944/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40572"
    },
    {
      "cve": "CVE-2025-40573",
      "cwe": {
        "id": "CWE-35",
        "name": "Path Traversal: \u0027.../...//\u0027"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices are vulnerable to path traversal attacks.\r\nThis could allow a privileged local attacker to restore backups that are outside the backup folder.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Restrict access to authorized and trusted personal only",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.0 HF0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109989944/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40573"
    },
    {
      "cve": "CVE-2025-40574",
      "cwe": {
        "id": "CWE-732",
        "name": "Incorrect Permission Assignment for Critical Resource"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do not properly assign permissions to critical ressources.\r\nThis could allow a non-privileged local attacker to interact with the backupmanager service.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Restrict access to authorized and trusted personal only",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.0 HF0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109989944/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40574"
    },
    {
      "cve": "CVE-2025-40575",
      "cwe": {
        "id": "CWE-457",
        "name": "Use of Uninitialized Variable"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do not properly validate incoming Profinet packets.\r\nAn unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcpd\r\nprocess.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Disable the Profinet Discovery and Configuration Protocol (DCP) service",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.0 HF0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109989944/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40575"
    },
    {
      "cve": "CVE-2025-40576",
      "cwe": {
        "id": "CWE-476",
        "name": "NULL Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do not properly validate incoming Profinet packets.\r\nAn unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcpd process.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Disable the Profinet Discovery and Configuration Protocol (DCP) service",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.0 HF0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109989944/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40576"
    },
    {
      "cve": "CVE-2025-40577",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do not properly validate incoming Profinet packets.\r\nAn unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcpd process.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Disable the Profinet Discovery and Configuration Protocol (DCP) service",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.0 HF0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109989944/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40577"
    },
    {
      "cve": "CVE-2025-40578",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do not properly handle multiple incoming Profinet packets received in rapid succession.\r\nAn unauthenticated remote attacker can exploit this flaw by sending multiple packets in a very short time frame, which leads to a crash of the dcpd process.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "2"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Disable the Profinet Discovery and Configuration Protocol (DCP) service",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "products": [
            "2"
          ]
        }
      ],
      "title": "CVE-2025-40578"
    },
    {
      "cve": "CVE-2025-40579",
      "cwe": {
        "id": "CWE-121",
        "name": "Stack-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices are vulnerable to a stack-based buffer overflow.\r\nThis could allow a non-privileged local attacker to execute arbitrary code on the device or to cause a denial of service condition.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Restrict access to authorized and trusted personal only",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.0 HF0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109989944/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40579"
    },
    {
      "cve": "CVE-2025-40580",
      "cwe": {
        "id": "CWE-121",
        "name": "Stack-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices are vulnerable to a stack-based buffer overflow.\r\nThis could allow a non-privileged local attacker to execute arbitrary code on the device or to cause a denial of service condition.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Restrict access to authorized and trusted personal only",
          "product_ids": [
            "1"
          ]
        },
        {
          "category": "vendor_fix",
          "details": "Update to V4.0 HF0 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://support.industry.siemens.com/cs/ww/en/view/109989944/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "1"
          ]
        }
      ],
      "title": "CVE-2025-40580"
    },
    {
      "cve": "CVE-2025-40581",
      "cwe": {
        "id": "CWE-288",
        "name": "Authentication Bypass Using an Alternate Path or Channel"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices are vulnerable to an authentication bypass.\r\nThis could allow a non-privileged local attacker to bypass the authentication of the SINEMA Remote Connect Edge Client, and to read and modify the configuration parameters.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "3"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Restrict access to authorized and trusted personal only",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "3"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "products": [
            "3"
          ]
        }
      ],
      "title": "CVE-2025-40581"
    },
    {
      "cve": "CVE-2025-40582",
      "cwe": {
        "id": "CWE-78",
        "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do not properly sanitize configuration parameters.\r\nThis could allow a non-privileged local attacker to execute root commands on the device.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "3"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Only use trusted SINEMA Remote Connect Servers",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "mitigation",
          "details": "Restrict access to authorized and trusted personal only",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "3"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "3"
          ]
        }
      ],
      "title": "CVE-2025-40582"
    },
    {
      "cve": "CVE-2025-40583",
      "cwe": {
        "id": "CWE-319",
        "name": "Cleartext Transmission of Sensitive Information"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected devices do transmit sensitive information in cleartext.\r\nThis could allow a privileged local attacker to retrieve this sensitive information.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "3"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "Restrict access to authorized and trusted personal only",
          "product_ids": [
            "3"
          ]
        },
        {
          "category": "none_available",
          "details": "Currently no fix is available",
          "product_ids": [
            "3"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "products": [
            "3"
          ]
        }
      ],
      "title": "CVE-2025-40583"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…