ssa-039007
Vulnerability from csaf_siemens
Published
2024-09-10 00:00
Modified
2024-11-12 00:00
Summary
SSA-039007: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)
Notes
Summary
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution.
Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-039007: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC) - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-039007.html" }, { "category": "self", "summary": "SSA-039007: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC) - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-039007.json" } ], "title": "SSA-039007: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)", "tracking": { "current_release_date": "2024-11-12T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-039007", "initial_release_date": "2024-09-10T00:00:00Z", "revision_history": [ { "date": "2024-09-10T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-10-08T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added fix for Totally Integrated Automation Portal (TIA Portal) V19 and clarified formulation for mitigation" }, { "date": "2024-11-12T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "Added affected products Opcenter Execution Foundation, Opcenter Quality and Opcenter RDL. Added fix for Totally Integrated Automation Portal (TIA Portal) V18. Clarified no fix planned for product Totally Integrated Automation Portal (TIA Portal) V16" } ], "status": "interim", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Opcenter Execution Foundation", "product_id": "1" } } ], "category": "product_name", "name": "Opcenter Execution Foundation" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Opcenter Quality", "product_id": "2" } } ], "category": "product_name", "name": "Opcenter Quality" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Opcenter RDL", "product_id": "3" } } ], "category": "product_name", "name": "Opcenter RDL" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC Information Server 2022", "product_id": "4" } } ], "category": "product_name", "name": "SIMATIC Information Server 2022" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC Information Server 2024", "product_id": "5" } } ], "category": "product_name", "name": "SIMATIC Information Server 2024" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC PCS neo V4.0", "product_id": "6" } } ], "category": "product_name", "name": "SIMATIC PCS neo V4.0" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V4.1 Update 2", "product": { "name": "SIMATIC PCS neo V4.1", "product_id": "7" } } ], "category": "product_name", "name": "SIMATIC PCS neo V4.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC PCS neo V5.0", "product_id": "8" } } ], "category": "product_name", "name": "SIMATIC PCS neo V5.0" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SINEC NMS", "product_id": "9" } } ], "category": "product_name", "name": "SINEC NMS" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V16", "product_id": "10" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V16" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V17 Update 8", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V17", "product_id": "11" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V17" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V18 Update 5", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V18", "product_id": "12" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V18" }, { "branches": [ { "category": "product_version_range", "name": "All versions \u003c V19 Update 3", "product": { "name": "Totally Integrated Automation Portal (TIA Portal) V19", "product_id": "13" } } ], "category": "product_name", "name": "Totally Integrated Automation Portal (TIA Portal) V19" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-33698", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13" ] }, "remediations": [ { "category": "mitigation", "details": "Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13" ] }, { "category": "mitigation", "details": "In addition if no RT server machines are used, port 4004 can be blocked completely", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "6", "10" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "1", "2", "3", "4", "5", "8" ] }, { "category": "vendor_fix", "details": "Update to V17 Update 8 or later version", "product_ids": [ "11" ] }, { "category": "vendor_fix", "details": "Update to V18 Update 5 or later version", "product_ids": [ "12" ] }, { "category": "vendor_fix", "details": "Update to V19 Update 3 or later version", "product_ids": [ "13" ] }, { "category": "vendor_fix", "details": "Update to V4.1 Update 2 or later version", "product_ids": [ "7" ] }, { "category": "vendor_fix", "details": "Update UMC to V2.11.6. Contact customer support to receive patch and update information.", "product_ids": [ "9" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13" ] } ], "title": "CVE-2024-33698" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.