Action not permitted
Modal body text goes here.
Modal Title
Modal Body
jvndb-2021-006146
Vulnerability from jvndb
Published
2021-12-28 11:51
Modified
2021-12-28 11:51
Severity ?
Summary
Multiple vulnerabilities in KONICA MINOLTA MFPs and printing systems
Details
Multi-function printers (MFP) and printing systems provided by KONICA MINOLTA, INC. contain multiple vulnerabilities listed below.
* Incorrect authorization (CWE-863) - CVE-2021-20868
* Exposure of sensitive information to an unauthorized actor (CWE-200) - CVE-2021-20869
* Improper handling of exceptional conditions (CWE-755) - CVE-2021-20870
* Exposure of sensitive information to an unauthorized actor (CWE-200) - CVE-2021-20871
* Protection mechanism failure (CWE-693) - CVE-2021-20872
KONICA MINOLTA, INC. reported these vulnerabilities to JPCERT/CC to notify users of the solutions through JVN.
References
Impacted products
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2021/JVNDB-2021-006146.html",
"dc:date": "2021-12-28T11:51+09:00",
"dcterms:issued": "2021-12-28T11:51+09:00",
"dcterms:modified": "2021-12-28T11:51+09:00",
"description": "Multi-function printers (MFP) and printing systems provided by KONICA MINOLTA, INC. contain multiple vulnerabilities listed below.\r\n\r\n* Incorrect authorization (CWE-863) - CVE-2021-20868\r\n* Exposure of sensitive information to an unauthorized actor (CWE-200) - CVE-2021-20869\r\n* Improper handling of exceptional conditions (CWE-755) - CVE-2021-20870\r\n* Exposure of sensitive information to an unauthorized actor (CWE-200) - CVE-2021-20871\r\n* Protection mechanism failure (CWE-693) - CVE-2021-20872\r\n\r\nKONICA MINOLTA, INC. reported these vulnerabilities to JPCERT/CC to notify users of the solutions through JVN.",
"link": "https://jvndb.jvn.jp/en/contents/2021/JVNDB-2021-006146.html",
"sec:cpe": {
"#text": "cpe:/a:konicaminolta:multiple_product",
"@product": "(multiple product)",
"@vendor": "Konica Minolta Business Solutions Japan Co., Ltd.",
"@version": "2.2"
},
"sec:cvss": [
{
"@score": "4.6",
"@severity": "Medium",
"@type": "Base",
"@vector": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"@version": "2.0"
},
{
"@score": "6.4",
"@severity": "Medium",
"@type": "Base",
"@vector": "CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"@version": "3.0"
}
],
"sec:identifier": "JVNDB-2021-006146",
"sec:references": [
{
"#text": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"@id": "JVNVU#95192472",
"@source": "JVN"
},
{
"#text": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2021-20868",
"@id": "CVE-2021-20868",
"@source": "CVE"
},
{
"#text": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2021-20869",
"@id": "CVE-2021-20869",
"@source": "CVE"
},
{
"#text": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2021-20870",
"@id": "CVE-2021-20870",
"@source": "CVE"
},
{
"#text": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2021-20871",
"@id": "CVE-2021-20871",
"@source": "CVE"
},
{
"#text": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2021-20872",
"@id": "CVE-2021-20872",
"@source": "CVE"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2021-20868",
"@id": "CVE-2021-20868",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2021-20869",
"@id": "CVE-2021-20869",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2021-20870",
"@id": "CVE-2021-20870",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2021-20871",
"@id": "CVE-2021-20871",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2021-20872",
"@id": "CVE-2021-20872",
"@source": "NVD"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-200",
"@title": "Information Exposure(CWE-200)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/693.html",
"@id": "CWE-693",
"@title": "Protection Mechanism Failure(CWE-693)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/755.html",
"@id": "CWE-755",
"@title": "Improper Handling of Exceptional Conditions(CWE-755)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/863.html",
"@id": "CWE-863",
"@title": "Incorrect Authorization(CWE-863)"
}
],
"title": "Multiple vulnerabilities in KONICA MINOLTA MFPs and printing systems"
}
CVE-2021-20868 (GCVE-0-2021-20868)
Vulnerability from cvelistv5
Published
2022-01-04 03:05
Modified
2024-08-03 17:53
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Incorrect authorization
Summary
Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Version: bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*] |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.012Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Incorrect authorization",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:20",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20868",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Incorrect authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20868",
"datePublished": "2022-01-04T03:05:20",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:23.012Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20871 (GCVE-0-2021-20871)
Vulnerability from cvelistv5
Published
2022-01-04 03:05
Modified
2024-08-03 17:53
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Exposure of sensitive information to an unauthorized actor
Summary
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Version: bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*] |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:22.675Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of sensitive information to an unauthorized actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:25",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20871",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20871",
"datePublished": "2022-01-04T03:05:25",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:22.675Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20869 (GCVE-0-2021-20869)
Vulnerability from cvelistv5
Published
2022-01-04 03:05
Modified
2024-08-03 17:53
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Exposure of sensitive information to an unauthorized actor
Summary
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Version: bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*] |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:22.996Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Exposure of sensitive information to an unauthorized actor",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:22",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20869",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Exposure of sensitive information to an unauthorized actor"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20869",
"datePublished": "2022-01-04T03:05:22",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:22.996Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20870 (GCVE-0-2021-20870)
Vulnerability from cvelistv5
Published
2022-01-04 03:05
Modified
2024-08-03 17:53
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Improper handling of exceptional conditions
Summary
Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Version: bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*] |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Improper handling of exceptional conditions",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:24",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20870",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper handling of exceptional conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20870",
"datePublished": "2022-01-04T03:05:24",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:23.136Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20872 (GCVE-0-2021-20872)
Vulnerability from cvelistv5
Published
2022-01-04 03:05
Modified
2024-08-03 17:53
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Protection mechanism failure
Summary
Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware.
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| KONICA MINOLTA, INC. | bizhub series |
Version: bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C385 ...[truncated*] |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:53:23.090Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "bizhub series",
"vendor": "KONICA MINOLTA, INC.",
"versions": [
{
"status": "affected",
"version": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C385 ...[truncated*]"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Protection mechanism failure",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-04T03:05:27",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
],
"x_ConverterErrors": {
"version_name": {
"error": "version_name too long. Use array of versions to record more than one version.",
"message": "Truncated!"
}
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2021-20872",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "bizhub series",
"version": {
"version_data": [
{
"version_value": "bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier"
}
]
}
}
]
},
"vendor_name": "KONICA MINOLTA, INC."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Protection mechanism failure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.com/global/newsroom/topics/2021/1224-01-01.html"
},
{
"name": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html",
"refsource": "MISC",
"url": "https://www.konicaminolta.jp/business/support/important/211224_01_01.html"
},
{
"name": "https://jvn.jp/en/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/en/vu/JVNVU95192472/index.html"
},
{
"name": "https://jvn.jp/vu/JVNVU95192472/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95192472/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2021-20872",
"datePublished": "2022-01-04T03:05:27",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:53:23.090Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…