Summary
Siemens RUGGEDCOM ROX (Update A)
Notes
Summary
Multiple vulnerabilities in RUGGEDCOM ROX devices have been detected, ranging from command injection to filesystem traversal. An attacker could exploit these to gain root access to the affected devices.
Siemens has released updates for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." }, { "names": [ "Michael Messner" ], "organization": "Siemens Energy", "summary": "reporting the vulnerabilities" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Multiple vulnerabilities in RUGGEDCOM ROX devices have been detected, ranging from command injection to filesystem traversal. An attacker could exploit these to gain root access to the affected devices.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-150692: Multiple Vulnerabilities in RUGGEDCOM ROX - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-150692.json" }, { "category": "self", "summary": "SSA-150692: Multiple Vulnerabilities in RUGGEDCOM ROX - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-150692.txt" }, { "category": "self", "summary": "SSA-150692: Multiple Vulnerabilities in RUGGEDCOM ROX - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-150692.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-259-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-259-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-259-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-259-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens RUGGEDCOM ROX (Update A)", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-259-01", "initial_release_date": "2021-09-14T00:00:00.000000Z", "revision_history": [ { "date": "2021-09-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2021-10-12T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Improvement of CVE description" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "3", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2.14.1", "product": { "name": "RUGGEDCOM ROX MX5000", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "RUGGEDCOM ROX MX5000" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.14.1", "product": { "name": "RUGGEDCOM ROX RX1400", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "RUGGEDCOM ROX RX1400" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.14.1", "product": { "name": "RUGGEDCOM ROX RX1500", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "RUGGEDCOM ROX RX1500" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.14.1", "product": { "name": "RUGGEDCOM ROX RX1501", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "RUGGEDCOM ROX RX1501" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.14.1", "product": { "name": "RUGGEDCOM ROX RX1510", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "RUGGEDCOM ROX RX1510" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.14.1", "product": { "name": "RUGGEDCOM ROX RX1511", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "RUGGEDCOM ROX RX1511" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.14.1", "product": { "name": "RUGGEDCOM ROX RX1512", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "RUGGEDCOM ROX RX1512" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.14.1", "product": { "name": "RUGGEDCOM ROX RX1524", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "RUGGEDCOM ROX RX1524" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.14.1", "product": { "name": "RUGGEDCOM ROX RX1536", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "RUGGEDCOM ROX RX1536" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.14.1", "product": { "name": "RUGGEDCOM ROX RX5000", "product_id": "CSAFPID-0010" } } ], "category": "product_name", "name": "RUGGEDCOM ROX RX5000" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-37173", "cwe": { "id": "CWE-269", "name": "Improper Privilege Management" }, "notes": [ { "category": "summary", "text": "The command line interface of affected devices insufficiently restrict file read and write operations for low privileged users.\n\nThis could allow an authenticated remote attacker to escalate privileges and gain root access to the device.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ] }, "references": [ { "summary": "CVE-2021-37173 - RUGGEDCOM ROX MX5000", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37173 - RUGGEDCOM ROX RX1400", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37173 - RUGGEDCOM ROX RX1500", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37173 - RUGGEDCOM ROX RX1501", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37173 - RUGGEDCOM ROX RX1510", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37173 - RUGGEDCOM ROX RX1511", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37173 - RUGGEDCOM ROX RX1512", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37173 - RUGGEDCOM ROX RX1524", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37173 - RUGGEDCOM ROX RX1536", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37173 - RUGGEDCOM ROX RX5000", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37173 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37173.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.14.1 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "category": "mitigation", "details": "Apply the principle of least privileges for accounts configured on the affected devices", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ] } ], "title": "CVE-2021-37173" }, { "cve": "CVE-2021-37174", "cwe": { "id": "CWE-250", "name": "Execution with Unnecessary Privileges" }, "notes": [ { "category": "summary", "text": "The affected devices have a privilege escalation vulnerability, if exploited, an attacker could gain root user access.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ] }, "references": [ { "summary": "CVE-2021-37174 - RUGGEDCOM ROX MX5000", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37174 - RUGGEDCOM ROX RX1400", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37174 - RUGGEDCOM ROX RX1500", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37174 - RUGGEDCOM ROX RX1501", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37174 - RUGGEDCOM ROX RX1510", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37174 - RUGGEDCOM ROX RX1511", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37174 - RUGGEDCOM ROX RX1512", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37174 - RUGGEDCOM ROX RX1524", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37174 - RUGGEDCOM ROX RX1536", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37174 - RUGGEDCOM ROX RX5000", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37174 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37174.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.14.1 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "category": "mitigation", "details": "Apply the principle of least privileges for accounts configured on the affected devices", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ] } ], "title": "CVE-2021-37174" }, { "cve": "CVE-2021-37175", "cwe": { "id": "CWE-280", "name": "Improper Handling of Insufficient Permissions or Privileges " }, "notes": [ { "category": "summary", "text": "The affected devices do not properly handle permissions to traverse the file system. If exploited, an attacker could gain access to an overview of the complete file system on the affected devices.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ] }, "references": [ { "summary": "CVE-2021-37175 - RUGGEDCOM ROX MX5000", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37175 - RUGGEDCOM ROX RX1400", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37175 - RUGGEDCOM ROX RX1500", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37175 - RUGGEDCOM ROX RX1501", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37175 - RUGGEDCOM ROX RX1510", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37175 - RUGGEDCOM ROX RX1511", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37175 - RUGGEDCOM ROX RX1512", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37175 - RUGGEDCOM ROX RX1524", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37175 - RUGGEDCOM ROX RX1536", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37175 - RUGGEDCOM ROX RX5000", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "summary": "CVE-2021-37175 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37175.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.14.1 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800780/" }, { "category": "mitigation", "details": "Apply the principle of least privileges for accounts configured on the affected devices", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010" ] } ], "title": "CVE-2021-37175" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…