icsa-14-133-01
Vulnerability from csaf_cisa
Published
2014-02-13 07:00
Modified
2025-06-09 19:48
Summary
Yokogawa Multiple Products Vulnerabilities
Notes
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-14-133-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2014/icsa-14-133-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-14-133-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-133-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014" } ], "title": "Yokogawa Multiple Products Vulnerabilities", "tracking": { "current_release_date": "2025-06-09T19:48:41.450208Z", "generator": { "date": "2025-06-09T19:48:41.450083Z", "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-14-133-01", "initial_release_date": "2014-02-13T07:00:00.000000Z", "revision_history": [ { "date": "2014-02-13T07:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Initial Publication" }, { "date": "2025-06-09T19:48:41.450208Z", "legacy_version": "CSAF Conversion", "number": "2", "summary": "Advisory converted into a CSAF" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "All_revisions", "product": { "name": "Yokogawa CENTUM CS 1000: All_revisions", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "CENTUM CS 1000" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R3.09.50", "product": { "name": "Yokogawa CENTUM CS 3000 Entry Class: \u003c=R3.09.50", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "CENTUM CS 3000 Entry Class" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R5.03.00", "product": { "name": "Yokogawa CENTUM VP: \u003c=R5.03.00", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "CENTUM VP" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R5.03.00", "product": { "name": "Yokogawa CENTUM VP Entry Class: \u003c=R5.03.00", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "CENTUM VP Entry Class" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R3.71.02", "product": { "name": "Yokogawa Exaopc: \u003c=R3.71.02", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "Exaopc" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R5.05.01", "product": { "name": "Yokogawa B/M9000CS: \u003c=R5.05.01", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "B/M9000CS" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R7.03.01", "product": { "name": "Yokogawa B/M9000 VP: \u003c=R7.03.01", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "B/M9000 VP" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R1.03.00", "product": { "name": "Yokogawa ProSafe-RS: \u003c=R1.03.00", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "ProSafe-RS" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R3.96.00", "product": { "name": "Yokogawa Exapilot: \u003c=R3.96.00", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "Exapilot" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R3.40.00", "product": { "name": "Yokogawa Exaplog: \u003c=R3.40.00", "product_id": "CSAFPID-0010" } } ], "category": "product_name", "name": "Exaplog" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=R2.02.50|\u003cR2.80.00", "product": { "name": "Yokogawa Exaquantum: \u003e=R2.02.50|\u003cR2.80.00", "product_id": "CSAFPID-0011" } } ], "category": "product_name", "name": "Exaquantum" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R4.03.20", "product": { "name": "Yokogawa Exasmoc: \u003c=R4.03.20", "product_id": "CSAFPID-0012" } } ], "category": "product_name", "name": "Exasmoc" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R4.03.20", "product": { "name": "Yokogawa Exarqe: \u003c=R4.03.20", "product_id": "CSAFPID-0013" } } ], "category": "product_name", "name": "Exarqe" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R1.20.13", "product": { "name": "Yokogawa AAASuite: \u003c=R1.20.13", "product_id": "CSAFPID-0014" } } ], "category": "product_name", "name": "AAASuite" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R3.11.20", "product": { "name": "Yokogawa PRM: \u003c=R3.11.20", "product_id": "CSAFPID-0015" } } ], "category": "product_name", "name": "PRM" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R3.40.01", "product": { "name": "Yokogawa STARDOM FCN/FCJ OPC Server for Windows: \u003c=R3.40.01", "product_id": "CSAFPID-0016" } } ], "category": "product_name", "name": "STARDOM FCN/FCJ OPC Server for Windows" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R2.01.01", "product": { "name": "Yokogawa Field Wireless Device OPC Server: \u003c=R2.01.01", "product_id": "CSAFPID-0017" } } ], "category": "product_name", "name": "Field Wireless Device OPC Server" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R3.01", "product": { "name": "Yokogawa DAQOPC: \u003c=R3.01", "product_id": "CSAFPID-0018" } } ], "category": "product_name", "name": "DAQOPC" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R1.03", "product": { "name": "Yokogawa FieldMate: \u003c=R1.03", "product_id": "CSAFPID-0019" } } ], "category": "product_name", "name": "FieldMate" }, { "branches": [ { "category": "product_version_range", "name": "\u003e=R1.02.00|\u003cR1.02.02", "product": { "name": "Yokogawa EJXMVTool: \u003e=R1.02.00|\u003cR1.02.02", "product_id": "CSAFPID-0020" } } ], "category": "product_name", "name": "EJXMVTool" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=R1.03.00", "product": { "name": "Yokogawa RPO Production Supervisor VP: \u003c=R1.03.00", "product_id": "CSAFPID-0021" } } ], "category": "product_name", "name": "RPO Production Supervisor VP" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Yokogawa CENTUM Long-term Trend Historian: vers:all/*", "product_id": "CSAFPID-0022" } } ], "category": "product_name", "name": "CENTUM Long-term Trend Historian" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Yokogawa CENTUM Event Viewer Package: vers:all/*", "product_id": "CSAFPID-0023" } } ], "category": "product_name", "name": "CENTUM Event Viewer Package" } ], "category": "vendor", "name": "Yokogawa" } ] }, "vulnerabilities": [ { "cve": "CVE-2014-0781", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Heap-based buffer overflow in BKCLogSvr.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via crafted UDP packets.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ] }, "remediations": [ { "category": "mitigation", "details": "Yokogawa has provided patch software for the latest revisions of the affected products. For details about individual countermeasures by the affected product, please refer to Yokogawa\u2019s Security Advisory Report at the following location: (http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ], "url": "http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm" } ], "scores": [ { "cvss_v2": { "baseScore": 9.3, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ] } ] }, { "cve": "CVE-2014-0783", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Stack-based buffer overflow in BKHOdeq.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ] }, "remediations": [ { "category": "mitigation", "details": "Yokogawa has provided patch software for the latest revisions of the affected products. For details about individual countermeasures by the affected product, please refer to Yokogawa\u2019s Security Advisory Report at the following location: (http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ], "url": "http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm" } ], "scores": [ { "cvss_v2": { "baseScore": 9.0, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ] } ] }, { "cve": "CVE-2014-0784", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Stack-based buffer overflow in BKBCopyD.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ] }, "remediations": [ { "category": "mitigation", "details": "Yokogawa has provided patch software for the latest revisions of the affected products. For details about individual countermeasures by the affected product, please refer to Yokogawa\u2019s Security Advisory Report at the following location: (http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ], "url": "http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm" } ], "scores": [ { "cvss_v2": { "baseScore": 8.3, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ] } ] }, { "cve": "CVE-2014-0782", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Stack-based buffer overflow in BKESimmgr.exe in the Expanded Test Functions package in Yokogawa CENTUM CS 1000, CENTUM CS 3000 Entry Class R3.09.50 and earlier, CENTUM VP R5.03.00 and earlier, CENTUM VP Entry Class R5.03.00 and earlier, Exaopc R3.71.02 and earlier, B/M9000CS R5.05.01 and earlier, and B/M9000 VP R7.03.01 and earlier allows remote attackers to execute arbitrary code via a crafted packet.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ] }, "remediations": [ { "category": "mitigation", "details": "Yokogawa has provided patch software for the latest revisions of the affected products. For details about individual countermeasures by the affected product, please refer to Yokogawa\u2019s Security Advisory Report at the following location: (http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ], "url": "http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm" } ], "scores": [ { "cvss_v2": { "baseScore": 8.3, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C", "version": "2.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023" ] } ] } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…