GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

GSD-2024-4111

Vulnerability from gsd - Updated: 2024-04-25 05:02
Details
A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Aliases

{
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2024-4111"
      ],
      "details": "A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.",
      "id": "GSD-2024-4111",
      "modified": "2024-04-25T05:02:08.607990Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cna@vuldb.com",
        "ID": "CVE-2024-4111",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "TX9",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "22.03.02.10"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Tenda"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
          },
          {
            "lang": "deu",
            "value": "Eine kritische Schwachstelle wurde in Tenda TX9 22.03.02.10 ausgemacht. Hierbei geht es um die Funktion sub_42BD7C der Datei /goform/SetLEDCfg. Durch Beeinflussen des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-121",
                "lang": "eng",
                "value": "CWE-121 Stack-based Buffer Overflow"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://vuldb.com/?id.261854",
            "refsource": "MISC",
            "url": "https://vuldb.com/?id.261854"
          },
          {
            "name": "https://vuldb.com/?ctiid.261854",
            "refsource": "MISC",
            "url": "https://vuldb.com/?ctiid.261854"
          },
          {
            "name": "https://vuldb.com/?submit.317205",
            "refsource": "MISC",
            "url": "https://vuldb.com/?submit.317205"
          },
          {
            "name": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/SetLEDCfg.md",
            "refsource": "MISC",
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/SetLEDCfg.md"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
          }
        ],
        "id": "CVE-2024-4111",
        "lastModified": "2024-04-24T17:16:50.397",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ]
        },
        "published": "2024-04-24T14:15:45.713",
        "references": [
          {
            "source": "cna@vuldb.com",
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/SetLEDCfg.md"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?ctiid.261854"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?id.261854"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?submit.317205"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-121"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…