gsd-2023-48784
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A use of externally-controlled format string vulnerability [CWE-134] in FortiOS version 7.4.1 and below, version 7.2.7 and below, version 7.0.14 and below, version 6.4.15 and below command line interface may allow a local privileged attacker with super-admin profile and CLI access to execute arbitrary code or commands via specially crafted requests.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-48784",
"id": "GSD-2023-48784"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-48784"
],
"details": "A\u00a0use of externally-controlled format string vulnerability [CWE-134] in FortiOS version 7.4.1 and below, version 7.2.7 and below, version 7.0.14 and below, version 6.4.15 and below command line interface may allow a local\u00a0privileged attacker with super-admin profile and CLI access\u00a0to execute arbitrary code or commands via specially crafted requests.",
"id": "GSD-2023-48784",
"modified": "2023-12-13T01:20:39.652153Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@fortinet.com",
"ID": "CVE-2023-48784",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "FortiOS",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "7.4.0",
"version_value": "7.4.1"
},
{
"version_affected": "\u003c=",
"version_name": "7.2.0",
"version_value": "7.2.7"
},
{
"version_affected": "\u003c=",
"version_name": "7.0.0",
"version_value": "7.0.15"
},
{
"version_affected": "\u003c=",
"version_name": "6.4.0",
"version_value": "6.4.15"
}
]
}
}
]
},
"vendor_name": "Fortinet"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A\u00a0use of externally-controlled format string vulnerability [CWE-134] in FortiOS version 7.4.1 and below, version 7.2.7 and below, 7.0 all versions, 6.4 all versions command line interface may allow a local\u00a0privileged attacker with super-admin profile and CLI access\u00a0to execute arbitrary code or commands via specially crafted requests."
}
]
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-134",
"lang": "eng",
"value": "Execute unauthorized code or commands"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://fortiguard.com/psirt/FG-IR-23-413",
"refsource": "MISC",
"url": "https://fortiguard.com/psirt/FG-IR-23-413"
}
]
},
"solution": [
{
"lang": "en",
"value": "Please upgrade to FortiOS version 7.4.2 or above \nPlease upgrade to FortiOS version 7.2.8 or above \n"
}
]
},
"nvd.nist.gov": {
"cve": {
"descriptions": [
{
"lang": "en",
"value": "A\u00a0use of externally-controlled format string vulnerability [CWE-134] in FortiOS version 7.4.1 and below, version 7.2.7 and below, 7.0 all versions, 6.4 all versions command line interface may allow a local\u00a0privileged attacker with super-admin profile and CLI access\u00a0to execute arbitrary code or commands via specially crafted requests."
},
{
"lang": "es",
"value": "El uso de una vulnerabilidad de cadena de formato controlada externamente [CWE-134] en FortiOS versi\u00f3n 7.4.1 e inferior, versi\u00f3n 7.2.7 e inferior, versi\u00f3n 7.0.14 e inferior, versi\u00f3n 6.4.15 e inferior, la interfaz de l\u00ednea de comando puede permitir una interfaz de l\u00ednea de comando local. Atacante privilegiado con perfil de superadministrador y acceso CLI para ejecutar c\u00f3digo o comandos arbitrarios a trav\u00e9s de solicitudes especialmente manipuladas."
}
],
"id": "CVE-2023-48784",
"lastModified": "2024-04-17T12:15:07.353",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9,
"source": "psirt@fortinet.com",
"type": "Secondary"
}
]
},
"published": "2024-04-09T15:15:28.617",
"references": [
{
"source": "psirt@fortinet.com",
"url": "https://fortiguard.com/psirt/FG-IR-23-413"
}
],
"sourceIdentifier": "psirt@fortinet.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-134"
}
],
"source": "psirt@fortinet.com",
"type": "Primary"
}
]
}
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…