Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into FactoryTalk® Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk® Services Platform web service.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2023-46290",
    "id": "GSD-2023-46290"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-46290"
      ],
      "details": "\nDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk\u00ae Services Platform web service and then use the token to log in into FactoryTalk\u00ae Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk\u00ae Services Platform web service.\n\n",
      "id": "GSD-2023-46290",
      "modified": "2023-12-13T01:20:53.269839Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "PSIRT@rockwellautomation.com",
        "ID": "CVE-2023-46290",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "FactoryTalk\u00ae Services Platform",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "versions before 2.80"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Rockwell Automation"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": " This vulnerability was found internally during routine testing."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "\nDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk\u00ae Services Platform web service and then use the token to log in into FactoryTalk\u00ae Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk\u00ae Services Platform web service.\n\n"
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-287",
                "lang": "eng",
                "value": "CWE-287 Improper Authentication"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165",
            "refsource": "MISC",
            "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165"
          }
        ]
      },
      "solution": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cul\u003e\u003cli\u003eInstall the respective \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx?crumb=113\u0026amp;versions=61602,60883,59837,59480,58564,57413,58591,59481,59482,59483,59484,59485,59486,59487,59488,59490,59491,59492,59493,59494,59495,59496\"\u003eFactoryTalk Services Version\u003c/a\u003e\u0026nbsp;that remediates the issue.\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012\"\u003eQA43240 - Recommended Security Guidelines from Rockwell Automation\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\n  *  Install the respective  FactoryTalk Services Version https://compatibility.rockwellautomation.com/Pages/MultiProductCompareSelections.aspx \u00a0that remediates the issue.\n  *   QA43240 - Recommended Security Guidelines from Rockwell Automation https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012 \n\n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_services_platform:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "2.80",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "PSIRT@rockwellautomation.com",
          "ID": "CVE-2023-46290"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "\nDue to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk\u00ae Services Platform web service and then use the token to log in into FactoryTalk\u00ae Services Platform . This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk\u00ae Services Platform web service.\n\n"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165",
              "refsource": "MISC",
              "tags": [
                "Permissions Required",
                "Vendor Advisory"
              ],
              "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141165"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.2,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2023-11-07T19:09Z",
      "publishedDate": "2023-10-27T19:15Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…