gsd-2023-44253
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in Fortinet FortiManager version 7.4.0 through 7.4.1 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.1 and before 7.2.5 and FortiAnalyzer-BigData before 7.2.5 allows an adom administrator to enumerate other adoms and device names via crafted HTTP or HTTPS requests.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-44253", "id": "GSD-2023-44253" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-44253" ], "details": "An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in Fortinet FortiManager version 7.4.0 through 7.4.1 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.1 and before 7.2.5 and FortiAnalyzer-BigData before 7.2.5 allows an adom administrator to enumerate other adoms and device names via crafted HTTP or HTTPS requests.", "id": "GSD-2023-44253", "modified": "2023-12-13T01:20:38.725775Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@fortinet.com", "ID": "CVE-2023-44253", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "FortiManager", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "7.4.0", "version_value": "7.4.1" }, { "version_affected": "\u003c=", "version_name": "7.2.0", "version_value": "7.2.3" }, { "version_affected": "\u003c=", "version_name": "7.0.0", "version_value": "7.0.11" }, { "version_affected": "\u003c=", "version_name": "6.4.0", "version_value": "6.4.14" }, { "version_affected": "\u003c=", "version_name": "6.2.0", "version_value": "6.2.12" } ] } }, { "product_name": "FortiAnalyzer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "7.4.0", "version_value": "7.4.1" }, { "version_affected": "\u003c=", "version_name": "7.2.0", "version_value": "7.2.3" }, { "version_affected": "\u003c=", "version_name": "7.0.0", "version_value": "7.0.11" }, { "version_affected": "\u003c=", "version_name": "6.4.0", "version_value": "6.4.14" }, { "version_affected": "\u003c=", "version_name": "6.2.0", "version_value": "6.2.12" } ] } } ] }, "vendor_name": "Fortinet" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in Fortinet FortiManager version 7.4.0 through 7.4.1 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.1 and before 7.2.5 and FortiAnalyzer-BigData before 7.2.5 allows an adom administrator to enumerate other adoms and device names via crafted HTTP or HTTPS requests." } ] }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N/E:P/RL:X/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-200", "lang": "eng", "value": "Information disclosure" } ] } ] }, "references": { "reference_data": [ { "name": "https://fortiguard.com/psirt/FG-IR-23-268", "refsource": "MISC", "url": "https://fortiguard.com/psirt/FG-IR-23-268" }, { "name": "https://github.com/orangecertcc/security-research/security/advisories/GHSA-25j8-69h7-83h2", "refsource": "MISC", "url": "https://github.com/orangecertcc/security-research/security/advisories/GHSA-25j8-69h7-83h2" } ] }, "solution": [ { "lang": "en", "value": "Please upgrade to FortiManager version 7.4.2 or above \nPlease upgrade to FortiManager version 7.2.4 or above \nPlease upgrade to FortiAnalyzer-BigData version 7.4.0 or above \nPlease upgrade to FortiAnalyzer-BigData version 7.2.6 or above \nPlease upgrade to FortiAnalyzer version 7.4.2 or above \nPlease upgrade to FortiAnalyzer version 7.2.4 or above \n" } ] }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*", "matchCriteriaId": "285EC81A-34F0-4153-82DE-6A49C05EB240", "versionEndIncluding": "6.2.12", "versionStartIncluding": "6.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*", "matchCriteriaId": "6AC08BD1-2008-4B3B-8594-A28F8DB9DC8C", "versionEndIncluding": "6.4.14", "versionStartIncluding": "6.4.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*", "matchCriteriaId": "FF3BCBBD-C706-4B2E-A01B-C1205EE28155", "versionEndIncluding": "7.0.11", "versionStartIncluding": "7.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*", "matchCriteriaId": "B31BB84A-E622-4911-AAB4-41E57F661A8D", "versionEndIncluding": "7.2.3", "versionStartIncluding": "7.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortianalyzer:7.4.0:*:*:*:*:*:*:*", "matchCriteriaId": "91A9AF01-72FD-4942-A95E-71A7609B6977", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortianalyzer:7.4.1:*:*:*:*:*:*:*", "matchCriteriaId": "838EB502-C11B-4ED6-9CF2-D067048F3A59", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*", "matchCriteriaId": "09105C5B-378F-4E1A-B395-F43573983A26", "versionEndIncluding": "6.2.12", "versionStartIncluding": "6.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E862237-362D-400A-A81E-305CDBD1077A", "versionEndIncluding": "6.4.14", "versionStartIncluding": "6.4.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*", "matchCriteriaId": "13D172A0-5DB2-4A3E-A984-BB57D39AEE36", "versionEndIncluding": "7.0.11", "versionStartIncluding": "7.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C7C73B7-2AE1-4FC2-A37A-89A085796D19", "versionEndIncluding": "7.2.3", "versionStartIncluding": "7.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortimanager:7.4.0:*:*:*:*:*:*:*", "matchCriteriaId": "DBBF7219-D15F-43C9-9A90-1A4B062431E4", "vulnerable": true }, { "criteria": "cpe:2.3:a:fortinet:fortimanager:7.4.1:*:*:*:*:*:*:*", "matchCriteriaId": "BF7F0AC2-9F06-4961-9671-B44B5B8EB701", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "descriptions": [ { "lang": "en", "value": "An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in Fortinet FortiManager version 7.4.0 through 7.4.1 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.1 and before 7.2.5 and FortiAnalyzer-BigData before 7.2.5 allows an adom administrator to enumerate other adoms and device names via crafted HTTP or HTTPS requests." }, { "lang": "es", "value": "Una exposici\u00f3n de informaci\u00f3n confidencial a una vulnerabilidad de actor no autorizado [CWE-200] en Fortinet FortiManager versi\u00f3n 7.4.0 a 7.4.1 y anteriores a 7.2.5, FortiAnalyzer versi\u00f3n 7.4.0 a 7.4.1 y anteriores a 7.2.5 y FortiAnalyzer-BigData Las versiones anteriores a 7.2.5 permiten a un administrador de adom enumerar otros adoms y nombres de dispositivos a trav\u00e9s de solicitudes HTTP o HTTPS manipuladas." } ], "id": "CVE-2023-44253", "lastModified": "2024-03-11T22:15:54.337", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.1, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.1, "impactScore": 1.4, "source": "psirt@fortinet.com", "type": "Secondary" } ] }, "published": "2024-02-15T14:15:44.830", "references": [ { "source": "psirt@fortinet.com", "tags": [ "Vendor Advisory" ], "url": "https://fortiguard.com/psirt/FG-IR-23-268" }, { "source": "psirt@fortinet.com", "url": "https://github.com/orangecertcc/security-research/security/advisories/GHSA-25j8-69h7-83h2" } ], "sourceIdentifier": "psirt@fortinet.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "psirt@fortinet.com", "type": "Secondary" } ] } } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.