gsd-2023-44253
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in Fortinet FortiManager version 7.4.0 through 7.4.1 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.1 and before 7.2.5 and FortiAnalyzer-BigData before 7.2.5 allows an adom administrator to enumerate other adoms and device names via crafted HTTP or HTTPS requests.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-44253",
"id": "GSD-2023-44253"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-44253"
],
"details": "An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in Fortinet FortiManager version 7.4.0 through 7.4.1 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.1 and before 7.2.5 and FortiAnalyzer-BigData before 7.2.5 allows an adom administrator to enumerate other adoms and device names via crafted HTTP or HTTPS requests.",
"id": "GSD-2023-44253",
"modified": "2023-12-13T01:20:38.725775Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@fortinet.com",
"ID": "CVE-2023-44253",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "FortiManager",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "7.4.0",
"version_value": "7.4.1"
},
{
"version_affected": "\u003c=",
"version_name": "7.2.0",
"version_value": "7.2.3"
},
{
"version_affected": "\u003c=",
"version_name": "7.0.0",
"version_value": "7.0.11"
},
{
"version_affected": "\u003c=",
"version_name": "6.4.0",
"version_value": "6.4.14"
},
{
"version_affected": "\u003c=",
"version_name": "6.2.0",
"version_value": "6.2.12"
}
]
}
},
{
"product_name": "FortiAnalyzer",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "7.4.0",
"version_value": "7.4.1"
},
{
"version_affected": "\u003c=",
"version_name": "7.2.0",
"version_value": "7.2.3"
},
{
"version_affected": "\u003c=",
"version_name": "7.0.0",
"version_value": "7.0.11"
},
{
"version_affected": "\u003c=",
"version_name": "6.4.0",
"version_value": "6.4.14"
},
{
"version_affected": "\u003c=",
"version_name": "6.2.0",
"version_value": "6.2.12"
}
]
}
}
]
},
"vendor_name": "Fortinet"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in Fortinet FortiManager version 7.4.0 through 7.4.1 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.1 and before 7.2.5 and FortiAnalyzer-BigData before 7.2.5 allows an adom administrator to enumerate other adoms and device names via crafted HTTP or HTTPS requests."
}
]
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N/E:P/RL:X/RC:C",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-200",
"lang": "eng",
"value": "Information disclosure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://fortiguard.com/psirt/FG-IR-23-268",
"refsource": "MISC",
"url": "https://fortiguard.com/psirt/FG-IR-23-268"
},
{
"name": "https://github.com/orangecertcc/security-research/security/advisories/GHSA-25j8-69h7-83h2",
"refsource": "MISC",
"url": "https://github.com/orangecertcc/security-research/security/advisories/GHSA-25j8-69h7-83h2"
}
]
},
"solution": [
{
"lang": "en",
"value": "Please upgrade to FortiManager version 7.4.2 or above \nPlease upgrade to FortiManager version 7.2.4 or above \nPlease upgrade to FortiAnalyzer-BigData version 7.4.0 or above \nPlease upgrade to FortiAnalyzer-BigData version 7.2.6 or above \nPlease upgrade to FortiAnalyzer version 7.4.2 or above \nPlease upgrade to FortiAnalyzer version 7.2.4 or above \n"
}
]
},
"nvd.nist.gov": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
"matchCriteriaId": "285EC81A-34F0-4153-82DE-6A49C05EB240",
"versionEndIncluding": "6.2.12",
"versionStartIncluding": "6.2.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6AC08BD1-2008-4B3B-8594-A28F8DB9DC8C",
"versionEndIncluding": "6.4.14",
"versionStartIncluding": "6.4.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FF3BCBBD-C706-4B2E-A01B-C1205EE28155",
"versionEndIncluding": "7.0.11",
"versionStartIncluding": "7.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B31BB84A-E622-4911-AAB4-41E57F661A8D",
"versionEndIncluding": "7.2.3",
"versionStartIncluding": "7.2.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortianalyzer:7.4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "91A9AF01-72FD-4942-A95E-71A7609B6977",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortianalyzer:7.4.1:*:*:*:*:*:*:*",
"matchCriteriaId": "838EB502-C11B-4ED6-9CF2-D067048F3A59",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "09105C5B-378F-4E1A-B395-F43573983A26",
"versionEndIncluding": "6.2.12",
"versionStartIncluding": "6.2.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7E862237-362D-400A-A81E-305CDBD1077A",
"versionEndIncluding": "6.4.14",
"versionStartIncluding": "6.4.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "13D172A0-5DB2-4A3E-A984-BB57D39AEE36",
"versionEndIncluding": "7.0.11",
"versionStartIncluding": "7.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7C7C73B7-2AE1-4FC2-A37A-89A085796D19",
"versionEndIncluding": "7.2.3",
"versionStartIncluding": "7.2.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortimanager:7.4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "DBBF7219-D15F-43C9-9A90-1A4B062431E4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortimanager:7.4.1:*:*:*:*:*:*:*",
"matchCriteriaId": "BF7F0AC2-9F06-4961-9671-B44B5B8EB701",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in Fortinet FortiManager version 7.4.0 through 7.4.1 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.1 and before 7.2.5 and FortiAnalyzer-BigData before 7.2.5 allows an adom administrator to enumerate other adoms and device names via crafted HTTP or HTTPS requests."
},
{
"lang": "es",
"value": "Una exposici\u00f3n de informaci\u00f3n confidencial a una vulnerabilidad de actor no autorizado [CWE-200] en Fortinet FortiManager versi\u00f3n 7.4.0 a 7.4.1 y anteriores a 7.2.5, FortiAnalyzer versi\u00f3n 7.4.0 a 7.4.1 y anteriores a 7.2.5 y FortiAnalyzer-BigData Las versiones anteriores a 7.2.5 permiten a un administrador de adom enumerar otros adoms y nombres de dispositivos a trav\u00e9s de solicitudes HTTP o HTTPS manipuladas."
}
],
"id": "CVE-2023-44253",
"lastModified": "2024-03-11T22:15:54.337",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.1,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.1,
"impactScore": 1.4,
"source": "psirt@fortinet.com",
"type": "Secondary"
}
]
},
"published": "2024-02-15T14:15:44.830",
"references": [
{
"source": "psirt@fortinet.com",
"tags": [
"Vendor Advisory"
],
"url": "https://fortiguard.com/psirt/FG-IR-23-268"
},
{
"source": "psirt@fortinet.com",
"url": "https://github.com/orangecertcc/security-research/security/advisories/GHSA-25j8-69h7-83h2"
}
],
"sourceIdentifier": "psirt@fortinet.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
],
"source": "psirt@fortinet.com",
"type": "Secondary"
}
]
}
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…