gsd-2023-35127
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
Stack-based buffer overflow may occur when Fuji Electric Tellus Lite V-Simulator parses a specially-crafted input file.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2023-35127",
    "id": "GSD-2023-35127"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-35127"
      ],
      "details": "Stack-based buffer overflow may occur when Fuji Electric Tellus Lite V-Simulator parses a specially-crafted input file.",
      "id": "GSD-2023-35127",
      "modified": "2023-12-13T01:20:46.079301Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "ID": "CVE-2023-35127",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Tellus Lite V-Simulator",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "0",
                          "version_value": "4.0.19.0"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Fuji Electric"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "Fritz Sands and kimiya working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Stack-based buffer overflow may occur when Fuji Electric Tellus Lite V-Simulator parses a specially-crafted input file."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-121",
                "lang": "eng",
                "value": "CWE-121 Stack-based Buffer Overflow"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-325-02",
            "refsource": "MISC",
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-325-02"
          },
          {
            "name": "https://felib.fujielectric.co.jp/en/M10009/M20034/document_detail/c27d5b69-68ef-4af5-90ee-b5dab118f71a",
            "refsource": "MISC",
            "url": "https://felib.fujielectric.co.jp/en/M10009/M20034/document_detail/c27d5b69-68ef-4af5-90ee-b5dab118f71a"
          }
        ]
      },
      "solution": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFuji Electric recommends users \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://felib.fujielectric.co.jp/en/M10009/M20034/document_detail/c27d5b69-68ef-4af5-90ee-b5dab118f71a\"\u003eupdate Tellus Lite V-Simulator to version 4.0.19.0.\u003c/a\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Fuji Electric recommends users  update Tellus Lite V-Simulator to version 4.0.19.0. https://felib.fujielectric.co.jp/en/M10009/M20034/document_detail/c27d5b69-68ef-4af5-90ee-b5dab118f71a"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:fujielectric:tellus_lite_v-simulator:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.0.19.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2023-35127"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Stack-based buffer overflow may occur when Fuji Electric Tellus Lite V-Simulator parses a specially-crafted input file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-325-02",
              "refsource": "",
              "tags": [
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-325-02"
            },
            {
              "name": "https://felib.fujielectric.co.jp/en/M10009/M20034/document_detail/c27d5b69-68ef-4af5-90ee-b5dab118f71a",
              "refsource": "",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://felib.fujielectric.co.jp/en/M10009/M20034/document_detail/c27d5b69-68ef-4af5-90ee-b5dab118f71a"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 1.8,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2023-11-30T17:24Z",
      "publishedDate": "2023-11-22T01:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.