A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2023-22611",
    "id": "GSD-2023-22611"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-22611"
      ],
      "details": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)",
      "id": "GSD-2023-22611",
      "modified": "2023-12-13T01:20:43.328130Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cybersecurity@schneider-electric.com",
        "ID": "CVE-2023-22611",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "\u003c",
                          "version_name": "All",
                          "version_value": "October 2022"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Schneider Electric"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)"
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "impact": {
        "cvss": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-200 Information Exposure"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf",
            "refsource": "MISC",
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
          }
        ]
      },
      "source": {
        "discovery": "UNKNOWN"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8108.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8120.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8158.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8182.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8197.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8218.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8269.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:84.8027.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7268.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7322.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7429.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7457.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7488.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7522.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7545.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7578.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7613.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7641.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7690.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7714.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7742.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7777.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7808.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7840.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7875.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7896.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7936.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.7980.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8015.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8108.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8122.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8155.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8172.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8197.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8220.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:81.8267.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7551.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7578.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7613.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7641.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7692.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7717.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7742.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7787.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7809.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7840.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7875.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7913.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7936.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.7980.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8017.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8108.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8122.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8155.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8181.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8197.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8221.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:83.8267.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2021:-:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2023-22611"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "NVD-CWE-noinfo"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf",
              "refsource": "MISC",
              "tags": [
                "Mitigation",
                "Patch",
                "Vendor Advisory"
              ],
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2023-02-07T19:56Z",
      "publishedDate": "2023-01-31T17:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…