gsd-2022-46141
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2022-46141",
"id": "GSD-2022-46141"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-46141"
],
"details": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions \u003c V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.",
"id": "GSD-2022-46141",
"modified": "2023-12-13T01:19:37.821383Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-46141",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC STEP 7 (TIA Portal)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V19"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions \u003c V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application."
}
]
},
"impact": {
"cvss": [
{
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-316",
"lang": "eng",
"value": "CWE-316: Cleartext Storage of Sensitive Information in Memory"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf"
}
]
}
},
"nvd.nist.gov": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F77226E4-F3B3-4D3B-B944-17CED48BD73A",
"versionEndExcluding": "19",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions \u003c V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Portal) (todas las versiones \u0026lt; V19). Una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n podr\u00eda permitir a un atacante local obtener acceso a la contrase\u00f1a de nivel de acceso de las CPU SIMATIC S7-1200 y S7-1500, cuando la ingresa un usuario leg\u00edtimo en la configuraci\u00f3n de hardware de la aplicaci\u00f3n afectada."
}
],
"id": "CVE-2022-46141",
"lastModified": "2023-12-15T15:25:08.557",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.6,
"impactScore": 3.6,
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
},
"published": "2023-12-12T12:15:10.003",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-312"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-316"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…