An incorrect user management vulnerability [CWE-286] in the FortiManager version 6.4.6 and below VDOM creation component may allow an attacker to access a FortiGate without a password via newly created VDOMs after the super_admin account is deleted.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2022-45857",
"description": "An incorrect user management vulnerability [CWE-286] in the FortiManager version 6.4.6 and below VDOM creation component may allow an attacker to access a FortiGate without a password via newly created VDOMs after the super_admin account is deleted.",
"id": "GSD-2022-45857"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-45857"
],
"details": "An incorrect user management vulnerability [CWE-286] in the FortiManager version 6.4.6 and below VDOM creation component may allow an attacker to access a FortiGate without a password via newly created VDOMs after the super_admin account is deleted.",
"id": "GSD-2022-45857",
"modified": "2023-12-13T01:19:24.723674Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@fortinet.com",
"ID": "CVE-2022-45857",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "FortiManager",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "7.0.0"
},
{
"version_affected": "=",
"version_value": "6.4.0"
},
{
"version_affected": "=",
"version_value": "6.2.0"
}
]
}
}
]
},
"vendor_name": "Fortinet"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An incorrect user management vulnerability [CWE-286] in the FortiManager version 6.4.6 and below VDOM creation component may allow an attacker to access a FortiGate without a password via newly created VDOMs after the super_admin account is deleted."
}
]
},
"impact": {
"cvss": [
{
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:L/A:H/E:F/RL:O/RC:C",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-286",
"lang": "eng",
"value": "Improper access control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://fortiguard.com/psirt/FG-IR-22-371",
"refsource": "MISC",
"url": "https://fortiguard.com/psirt/FG-IR-22-371"
}
]
},
"solution": [
{
"lang": "en",
"value": "Please upgrade to FortiManager version 7.0.2 or above\r\nPlease upgrade to FortiManager version 6.4.8 or above\r\nPlease upgrade to FortiManager version 6.2.9 or above"
}
]
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.4.8",
"versionStartIncluding": "6.4.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "7.0.2",
"versionStartIncluding": "7.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.2.9",
"versionStartIncluding": "6.2.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "psirt@fortinet.com",
"ID": "CVE-2022-45857"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "An incorrect user management vulnerability [CWE-286] in the FortiManager version 6.4.6 and below VDOM creation component may allow an attacker to access a FortiGate without a password via newly created VDOMs after the super_admin account is deleted."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://fortiguard.com/psirt/FG-IR-22-371",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://fortiguard.com/psirt/FG-IR-22-371"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.6,
"impactScore": 5.3
}
},
"lastModifiedDate": "2023-01-11T17:23Z",
"publishedDate": "2023-01-05T08:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…