gsd-2022-42970
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-42970", "description": "A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)", "id": "GSD-2022-42970" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-42970" ], "details": "A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)", "id": "GSD-2022-42970", "modified": "2023-12-13T01:19:10.366931Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "DATE_PUBLIC": "2022-12-13T08:00:00.000Z", "ID": "CVE-2022-42970", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "APC Easy UPS Online Monitoring Software", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022", "version_value": "V2.5-GA" } ] } }, { "product_name": "APC Easy UPS Online Monitoring Software", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "(Windows 11, Windows Server 2019, 2022", "version_value": "V2.5-GA-01-22261" } ] } }, { "product_name": "Schneider Electric Easy UPS Online Monitoring Software", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "Windows 7, 10, 11 Windows Server 2016, 2019, 2022", "version_value": "V2.5-GS" } ] } }, { "product_name": "Schneider Electric Easy UPS Online Monitoring Software", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "Windows 11, Windows Server 2019, 2022", "version_value": "V2.5-GS-01-22261" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306 Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ] }, "source": { "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5-ga-01-22320", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5-gs-01-22320", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5-ga", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5-gs", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:-:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2022-42970" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A CWE-306: Missing Authentication for Critical Function The software does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 \u0026 Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-306" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_SEVD-2022-347-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-347-01_Easy_UPS_Online_Monitoring_Software_Security_Notification.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2023-02-08T19:52Z", "publishedDate": "2023-02-01T04:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…