gsd-2022-39060
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
ChangingTech MegaServiSignAdapter component has a vulnerability of improper input validation. An unauthenticated remote attacker can exploit this vulnerability to access and modify HKEY_CURRENT_USER subkey (ex: AutoRUN) in Registry where malicious scripts can be executed to take control of the system or to terminate the service.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2022-39060",
"description": "ChangingTech MegaServiSignAdapter component has a vulnerability of improper input validation. An unauthenticated remote attacker can exploit this vulnerability to access and modify HKEY_CURRENT_USER subkey (ex: AutoRUN) in Registry where malicious scripts can be executed to take control of the system or to terminate the service.",
"id": "GSD-2022-39060"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-39060"
],
"details": "ChangingTech MegaServiSignAdapter component has a vulnerability of improper input validation. An unauthenticated remote attacker can exploit this vulnerability to access and modify HKEY_CURRENT_USER subkey (ex: AutoRUN) in Registry where malicious scripts can be executed to take control of the system or to terminate the service.",
"id": "GSD-2022-39060",
"modified": "2023-12-13T01:19:20.756814Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"AKA": "TWCERT/CC",
"ASSIGNER": "cve@cert.org.tw",
"DATE_PUBLIC": "2023-01-31T07:35:00.000Z",
"ID": "CVE-2022-39060",
"STATE": "PUBLIC",
"TITLE": "ChangingTec MegaServiSignAdapter - Improper Input Validation"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MegaServiSignAdapter",
"version": {
"version_data": [
{
"platform": "Windows",
"version_affected": "=",
"version_value": "1.0.17.0823"
}
]
}
}
]
},
"vendor_name": "ChangingTec"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "DEVCORE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "ChangingTech MegaServiSignAdapter component has a vulnerability of improper input validation. An unauthenticated remote attacker can exploit this vulnerability to access and modify HKEY_CURRENT_USER subkey (ex: AutoRUN) in Registry where malicious scripts can be executed to take control of the system or to terminate the service."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.twcert.org.tw/tw/cp-132-6887-6ed4f-1.html",
"refsource": "MISC",
"url": "https://www.twcert.org.tw/tw/cp-132-6887-6ed4f-1.html"
}
]
},
"solution": [
{
"lang": "eng",
"value": "Update MegaServiSignAdapter (Windows) version to 1.0.22.1004"
}
],
"source": {
"advisory": "TVN-202212009",
"discovery": "EXTERNAL"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:changingtec:megaservisignadapter:*:*:*:*:*:windows:*:*",
"cpe_name": [],
"versionEndExcluding": "1.0.22.1004",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@cert.org.tw",
"ID": "CVE-2022-39060"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "ChangingTech MegaServiSignAdapter component has a vulnerability of improper input validation. An unauthenticated remote attacker can exploit this vulnerability to access and modify HKEY_CURRENT_USER subkey (ex: AutoRUN) in Registry where malicious scripts can be executed to take control of the system or to terminate the service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.twcert.org.tw/tw/cp-132-6887-6ed4f-1.html",
"refsource": "MISC",
"tags": [
"Third Party Advisory"
],
"url": "https://www.twcert.org.tw/tw/cp-132-6887-6ed4f-1.html"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-02-07T17:42Z",
"publishedDate": "2023-01-31T08:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…