gsd-2022-3160
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
The APDFL.dll contains an out-of-bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-3160", "id": "GSD-2022-3160" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-3160" ], "details": "The APDFL.dll contains an out-of-bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process.", "id": "GSD-2022-3160", "modified": "2023-12-13T01:19:39.907873Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-3160", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "JT2Go", "version": { "version_data": [ { "version_affected": "=", "version_value": "0" } ] } }, { "product_name": "Teamcenter Visualization V13.3", "version": { "version_data": [ { "version_affected": "=", "version_value": "0" } ] } }, { "product_name": "Teamcenter Visualization V14.0", "version": { "version_data": [ { "version_affected": "=", "version_value": "0" } ] } }, { "product_name": "Teamcenter Visualization V14.1", "version": { "version_data": [ { "version_affected": "=", "version_value": "0" } ] } } ] }, "vendor_name": "Siemens\u00a0" } ] } }, "credits": [ { "lang": "en", "value": "Michael Heinz and Nafiez reported these vulnerabilities to Siemens.\u00a0" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The APDFL.dll contains an out-of-bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-122", "lang": "eng", "value": "CWE-122" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15" }, { "name": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html" }, { "name": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json" } ] }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\nSiemens released updates for the affected products and recommends updating to the latest versions:\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eJT2Go: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u0026nbsp;\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V13.3: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V13.3.0.8 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.0: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.0.0.4 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003cbr\u003e\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eTeamcenter Visualization V14.1: \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.sw.siemens.com/\"\u003eUpdate to V14.1.0.5 or later version\u003c/a\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e" } ], "value": "Siemens released updates for the affected products and recommends updating to the latest versions:\n * JT2Go: Update to V14.1.0.5 or later version https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html .\u00a0\n\n * Teamcenter Visualization V13.3: Update to V13.3.0.8 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.0: Update to V14.0.0.4 or later version https://support.sw.siemens.com/ .\n\n * Teamcenter Visualization V14.1: Update to V14.1.0.5 or later version https://support.sw.siemens.com/ .\n\n\n" } ], "source": { "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\u003cp\u003eSiemens identified the following specific workaround and mitigation user can apply to reduce risk: \u003c/p\u003e\n\n\u003cul\u003e\u003cli\u003eDo not open untrusted PDF files in JT2Go and Teamcenter Visualization.\u003c/li\u003e\n\u003c/ul\u003e\u003cp\u003eAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/operational-guidelines-industrial-security\"\u003eoperational guidelines for industrial security\u003c/a\u003e\u003c/p\u003e and following the recommendations in the product manuals. Siemens also provides \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/industrialsecurity\"\u003eadditional information on industrial security\u003c/a\u003e.\u003cbr\u003e\nFor further inquiries on security vulnerabilities in Siemens products, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.siemens.com/cert/advisories\"\u003eSiemens\u003c/a\u003e. \u003cbr\u003e\nFor more information, see the associated Siemens security advisory SSA-360681 in \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/html/ssa-360681.html\"\u003eHTML \u003c/a\u003eand \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json\"\u003eCSAF\u003c/a\u003e.\n\n\u003cbr\u003e" } ], "value": "Siemens identified the following specific workaround and mitigation user can apply to reduce risk: \n\n\n\n * Do not open untrusted PDF files in JT2Go and Teamcenter Visualization.\n\n\n\nAs a general security measure, Siemens recommends protecting \nnetwork access to devices with appropriate mechanisms. To operate the \ndevices in a protected IT environment, Siemens recommends configuring \nthe environment according to Siemens\u0027 operational guidelines for industrial security https://www.siemens.com/cert/operational-guidelines-industrial-security \n\n and following the recommendations in the product manuals. Siemens also provides additional information on industrial security https://www.siemens.com/industrialsecurity .\n\nFor further inquiries on security vulnerabilities in Siemens products, users should contact Siemens https://www.siemens.com/cert/advisories . \n\nFor more information, see the associated Siemens security advisory SSA-360681 in HTML https://cert-portal.siemens.com/productcert/html/ssa-360681.html and CSAF https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json .\n\n\n" } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.0.0.4", "versionStartIncluding": "14.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.3.0.8", "versionStartIncluding": "13.3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.1.0.5", "versionStartIncluding": "14.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "14.1.0.5", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-3160" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "The APDFL.dll contains an out-of-bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-787" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-349-15" }, { "name": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-360681.html" }, { "name": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-360681.json" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-01-23T18:33Z", "publishedDate": "2023-01-13T01:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.