gsd-2022-29830
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2022-29830",
"id": "GSD-2022-29830"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-29830"
],
"details": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.",
"id": "GSD-2022-29830",
"modified": "2023-12-13T01:19:41.890435Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-29830",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GX Works3",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "from 1.000A to 1.095Z"
}
]
}
},
{
"product_name": "Motion Control Setting(GX Works3 related software)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "from 1.000A and later"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally."
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-321",
"lang": "eng",
"value": "CWE-321 Use of Hard-coded Cryptographic Key"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU97244961/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU97244961/index.html"
},
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionStartIncluding": "1.087r",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.086q",
"versionStartIncluding": "1.015r",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.011m",
"versionStartIncluding": "1.000a",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-29830"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Motion Control Setting(GX Works3 related software) versions from 1.000A and later allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://jvn.jp/vu/JVNVU97244961/index.html",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://jvn.jp/vu/JVNVU97244961/index.html"
},
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf",
"refsource": "MISC",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf"
},
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05",
"refsource": "MISC",
"tags": [],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2
}
},
"lastModifiedDate": "2023-06-29T08:15Z",
"publishedDate": "2022-11-25T00:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…