gsd-2022-23128
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2022-23128",
    "description": "Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products.",
    "id": "GSD-2022-23128"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2022-23128"
      ],
      "details": "Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products.",
      "id": "GSD-2022-23128",
      "modified": "2023-12-13T01:19:35.265883Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "ID": "CVE-2022-23128",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Mitsubishi Electric MC Works64; ICONICS GENESIS64; ICONICS Hyper Historian; ICONICS AnalytiX; ICONICS MobileHMI",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01)"
                        },
                        {
                          "version_value": "ICONICS GENESIS64 versions 10.95.3 to 10.97"
                        },
                        {
                          "version_value": "ICONICS Hyper Historian versions 10.95.3 to 10.97"
                        },
                        {
                          "version_value": "ICONICS AnalytiX versions 10.95.3 to 10.97"
                        },
                        {
                          "version_value": "ICONICS MobileHMI versions 10.95.3 to 10.97"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "Incomplete List of Disallowed Inputs"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://jvn.jp/vu/JVNVU95403720/index.html",
            "refsource": "MISC",
            "url": "https://jvn.jp/vu/JVNVU95403720/index.html"
          },
          {
            "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01",
            "refsource": "MISC",
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01"
          },
          {
            "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf",
            "refsource": "MISC",
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:iconics:analytix:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "10.97",
                "versionStartIncluding": "10.95.3",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "10.97",
                "versionStartIncluding": "10.95.3",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:iconics:hyper_historian:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "10.97",
                "versionStartIncluding": "10.95.3",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:iconics:mobilehmi:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "10.97",
                "versionStartIncluding": "10.95.3",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "10.95.210.01",
                "versionStartIncluding": "10.95.201.23",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
          "ID": "CVE-2022-23128"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "NVD-CWE-Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01",
              "refsource": "MISC",
              "tags": [
                "Mitigation",
                "Third Party Advisory",
                "US Government Resource",
                "VDB Entry"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01"
            },
            {
              "name": "https://jvn.jp/vu/JVNVU95403720/index.html",
              "refsource": "MISC",
              "tags": [
                "Mitigation",
                "Third Party Advisory",
                "VDB Entry"
              ],
              "url": "https://jvn.jp/vu/JVNVU95403720/index.html"
            },
            {
              "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf",
              "refsource": "MISC",
              "tags": [
                "Mitigation",
                "Vendor Advisory"
              ],
              "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 6.4,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "HIGH",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2022-01-27T20:20Z",
      "publishedDate": "2022-01-21T19:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.