gsd-2021-25667
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2021-25667",
"description": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.",
"id": "GSD-2021-25667"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-25667"
],
"details": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.",
"id": "GSD-2021-25667",
"modified": "2023-12-13T01:23:21.759600Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-25667",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "RUGGEDCOM RM1224",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V4.3 and \u003c V6.4"
}
]
}
},
{
"product_name": "SCALANCE M-800",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V4.3 and \u003c V6.4"
}
]
}
},
{
"product_name": "SCALANCE S615",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V4.3 and \u003c V6.4"
}
]
}
},
{
"product_name": "SCALANCE SC-600 Family",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.0 and \u003c V2.1.3"
}
]
}
},
{
"product_name": "SCALANCE XB-200",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE XC-200",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE XF-200BA",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE XM400",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V6.2"
}
]
}
},
{
"product_name": "SCALANCE XP-200",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE XR-300WG",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.1"
}
]
}
},
{
"product_name": "SCALANCE XR500",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V6.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.4",
"versionStartIncluding": "4.3",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rm1224:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.4",
"versionStartIncluding": "4.3",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.4",
"versionStartIncluding": "4.3",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x300wg_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x300wg:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.1.3",
"versionStartIncluding": "2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_sc622-2c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.1.3",
"versionStartIncluding": "2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_sc632-2c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.1.3",
"versionStartIncluding": "2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_sc636-2c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.1.3",
"versionStartIncluding": "2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_sc642-2c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.1.3",
"versionStartIncluding": "2.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_sc646-2c:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-25667"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03",
"refsource": "MISC",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2022-10-19T19:26Z",
"publishedDate": "2021-03-15T17:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…