gsd-2021-25667
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2021-25667", "description": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.", "id": "GSD-2021-25667" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-25667" ], "details": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.", "id": "GSD-2021-25667", "modified": "2023-12-13T01:23:21.759600Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-25667", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RUGGEDCOM RM1224", "version": { "version_data": [ { "version_value": "All versions \u003e= V4.3 and \u003c V6.4" } ] } }, { "product_name": "SCALANCE M-800", "version": { "version_data": [ { "version_value": "All versions \u003e= V4.3 and \u003c V6.4" } ] } }, { "product_name": "SCALANCE S615", "version": { "version_data": [ { "version_value": "All versions \u003e= V4.3 and \u003c V6.4" } ] } }, { "product_name": "SCALANCE SC-600 Family", "version": { "version_data": [ { "version_value": "All versions \u003e= V2.0 and \u003c V2.1.3" } ] } }, { "product_name": "SCALANCE XB-200", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XC-200", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XF-200BA", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XM400", "version": { "version_data": [ { "version_value": "All versions \u003c V6.2" } ] } }, { "product_name": "SCALANCE XP-200", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XR-300WG", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1" } ] } }, { "product_name": "SCALANCE XR500", "version": { "version_data": [ { "version_value": "All versions \u003c V6.2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121: Stack-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.4", "versionStartIncluding": "4.3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rm1224:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.4", "versionStartIncluding": "4.3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.4", "versionStartIncluding": "4.3", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x300wg_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x300wg:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.1.3", "versionStartIncluding": "2.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_sc622-2c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.1.3", "versionStartIncluding": "2.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_sc632-2c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.1.3", "versionStartIncluding": "2.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_sc636-2c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.1.3", "versionStartIncluding": "2.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_sc642-2c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.1.3", "versionStartIncluding": "2.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_sc646-2c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-25667" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE M-800 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE S615 (All versions \u003e= V4.3 and \u003c V6.4), SCALANCE SC-600 Family (All versions \u003e= V2.0 and \u003c V2.1.3), SCALANCE XB-200 (All versions \u003c V4.1), SCALANCE XC-200 (All versions \u003c V4.1), SCALANCE XF-200BA (All versions \u003c V4.1), SCALANCE XM400 (All versions \u003c V6.2), SCALANCE XP-200 (All versions \u003c V4.1), SCALANCE XR-300WG (All versions \u003c V4.1), SCALANCE XR500 (All versions \u003c V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-121" } ] } ] }, "references": { "reference_data": [ { "name": "N/A", "refsource": "CONFIRM", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03", "refsource": "MISC", "tags": [ "Patch", "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } }, "lastModifiedDate": "2022-10-19T19:26Z", "publishedDate": "2021-03-15T17:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.