gsd-2021-20827
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
Plaintext storage of a password vulnerability in IDEC PLCs (FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier) allows an attacker to obtain the PLC Web server user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the attacker may access the PLC Web server and hijack the PLC, and manipulation of the PLC output and/or suspension of the PLC may be conducted.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2021-20827", "description": "Plaintext storage of a password vulnerability in IDEC PLCs (FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier) allows an attacker to obtain the PLC Web server user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the attacker may access the PLC Web server and hijack the PLC, and manipulation of the PLC output and/or suspension of the PLC may be conducted.", "id": "GSD-2021-20827" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-20827" ], "details": "Plaintext storage of a password vulnerability in IDEC PLCs (FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier) allows an attacker to obtain the PLC Web server user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the attacker may access the PLC Web server and hijack the PLC, and manipulation of the PLC output and/or suspension of the PLC may be conducted.", "id": "GSD-2021-20827", "modified": "2023-12-13T01:23:12.123038Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "vultures@jpcert.or.jp", "ID": "CVE-2021-20827", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "IDEC PLC", "version": { "version_data": [ { "version_value": "FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier" } ] } } ] }, "vendor_name": "IDEC Corporation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Plaintext storage of a password vulnerability in IDEC PLCs (FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier) allows an attacker to obtain the PLC Web server user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the attacker may access the PLC Web server and hijack the PLC, and manipulation of the PLC output and/or suspension of the PLC may be conducted." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Plaintext storage of a password" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.idec.com/home/lp/pdf/2021-12-24-PLC.pdf", "refsource": "MISC", "url": "https://www.idec.com/home/lp/pdf/2021-12-24-PLC.pdf" }, { "name": "https://jvn.jp/en/vu/JVNVU92279973/index.html", "refsource": "MISC", "url": "https://jvn.jp/en/vu/JVNVU92279973/index.html" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:idec:microsmart_fc6a_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.32", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:idec:microsmart_fc6a:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:idec:microsmart_plus_fc6a_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.91", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:idec:microsmart_plus_fc6a:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:idec:data_file_manager:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.12.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:idec:windedit:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.3.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:idec:windldr:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "8.19.1", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "vultures@jpcert.or.jp", "ID": "CVE-2021-20827" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Plaintext storage of a password vulnerability in IDEC PLCs (FC6A Series MICROSmart All-in-One CPU module v2.32 and earlier, FC6A Series MICROSmart Plus CPU module v1.91 and earlier, WindLDR v8.19.1 and earlier, WindEDIT Lite v1.3.1 and earlier, and Data File Manager v2.12.1 and earlier) allows an attacker to obtain the PLC Web server user credentials from file servers, backup repositories, or ZLD files saved in SD cards. As a result, the attacker may access the PLC Web server and hijack the PLC, and manipulation of the PLC output and/or suspension of the PLC may be conducted." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-312" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.idec.com/home/lp/pdf/2021-12-24-PLC.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.idec.com/home/lp/pdf/2021-12-24-PLC.pdf" }, { "name": "https://jvn.jp/en/vu/JVNVU92279973/index.html", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/vu/JVNVU92279973/index.html" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2022-01-11T18:42Z", "publishedDate": "2021-12-24T07:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.