gsd-2019-6695
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
Lack of root file system integrity checking in Fortinet FortiManager VM application images of 6.2.0, 6.0.6 and below may allow an attacker to implant third-party programs by recreating the image through specific methods.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2019-6695",
"description": "Lack of root file system integrity checking in Fortinet FortiManager VM application images of 6.2.0, 6.0.6 and below may allow an attacker to implant third-party programs by recreating the image through specific methods.",
"id": "GSD-2019-6695"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2019-6695"
],
"details": "Lack of root file system integrity checking in Fortinet FortiManager VM application images of 6.2.0, 6.0.6 and below may allow an attacker to implant third-party programs by recreating the image through specific methods.",
"id": "GSD-2019-6695",
"modified": "2023-12-13T01:23:48.916296Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@fortinet.com",
"ID": "CVE-2019-6695",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Fortinet FortiManager",
"version": {
"version_data": [
{
"version_value": "FortiManager all versions below 6.2.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Lack of root file system integrity checking in Fortinet FortiManager VM application images of 6.2.0, 6.0.6 and below may allow an attacker to implant third-party programs by recreating the image through specific methods."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Execute unauthorized code or commands"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://fortiguard.com/advisory/FG-IR-19-017",
"refsource": "CONFIRM",
"url": "https://fortiguard.com/advisory/FG-IR-19-017"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:fortinet:fortimanager:6.2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:virtual_machine:*:*:*",
"cpe_name": [],
"versionEndIncluding": "6.0.6",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "psirt@fortinet.com",
"ID": "CVE-2019-6695"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Lack of root file system integrity checking in Fortinet FortiManager VM application images of 6.2.0, 6.0.6 and below may allow an attacker to implant third-party programs by recreating the image through specific methods."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-345"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://fortiguard.com/advisory/FG-IR-19-017",
"refsource": "CONFIRM",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://fortiguard.com/advisory/FG-IR-19-017"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-03-01T18:38Z",
"publishedDate": "2019-08-23T21:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…