gsd-2019-19301
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2019-19301", "description": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions), SIMATIC CP 443-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC RF180C (All versions), SIMATIC RF182C (All versions). The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.", "id": "GSD-2019-19301" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-19301" ], "details": "A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.", "id": "GSD-2019-19301", "modified": "2023-12-13T01:23:53.730169Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-19301", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X200-4P IRT", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X201-3P IRT", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X201-3P IRT PRO", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X202-2IRT", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X202-2P IRT", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X202-2P IRT PRO", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X204-2", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2FM", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2LD", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2LD TS", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204-2TS", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X204IRT", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X204IRT PRO", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X206-1", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X206-1LD", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X208", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X208PRO", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X212-2", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X212-2LD", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X216", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X224", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE X302-7 EEC (230V, coated)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (230V)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (24V, coated)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (24V)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 230V)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X302-7 EEC (2x 24V)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X304-2FE", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X306-1LD FE", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (230V, coated)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (230V)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (24V, coated)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (24V)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 230V)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-2 EEC (2x 24V)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-3", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X307-3LD", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LD", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LH", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2LH+", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M PoE", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X308-2M TS", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X310", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X310FE", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X320-1 FE", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X320-1-2LD FE", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE X408-2", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XF201-3P IRT", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE XF202-2P IRT", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE XF204", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XF204-2", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XF204-2BA IRT", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE XF204IRT", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE XF206-1", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XF208", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V5.2.5" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on front)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (230V, ports on rear)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on front)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M (24V, ports on rear)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-12M TS (24V)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" }, { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } }, { "product_name": "SIMATIC CP 343-1 Advanced", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } }, { "product_name": "SIMATIC CP 442-1 RNA", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V1.5.18" } ] } }, { "product_name": "SIMATIC CP 443-1", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V3.3" }, { "version_affected": "=", "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC CP 443-1 Advanced", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIMATIC CP 443-1 RNA", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V1.5.18" } ] } }, { "product_name": "SIMATIC RF180C", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } }, { "product_name": "SIMATIC RF182C", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } }, { "product_name": "SIPLUS NET CP 343-1 Advanced", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } }, { "product_name": "SIPLUS NET CP 443-1", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIPLUS NET CP 443-1 Advanced", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "SIPLUS NET SCALANCE X308-2", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions \u003c V4.1.4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service." } ] }, "impact": { "cvss": [ { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:U/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-400", "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "5.5.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x-200irt_pro_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x-200irt_pro:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_443-1_advanced_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_443-1_advanced:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf180c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf180c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf182c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf182c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-19301" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-400" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2023-04-11T10:15Z", "publishedDate": "2020-04-14T20:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.